IAC

B&R 8I77T200400.0P-000

ACOPOSinverter P77, 3x 195-264 V; 4 kW (heavy duty), 20.6 A (@4 kHz), integrated brake chopper, HTL encoder input onboard, 2-channel STO (SIL 3, PL e), POWERLINK hub with 2x RJ45, physical node number switches, shield plate included in delivery

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

General information
Certifications / CEYes
Certifications / UKCAYes
Certifications / ULcULus E225616 Power conversion equipment
Motor power
Specified on nameplate4 kW (5 HP)
Mains connection
Mains current / At 400 VAC20.6 A
Mains current / At 480 VAC20.6 A
Mains input voltage3x 195 VAC -15% to 264 VAC +10%
Frequency45 to 65 Hz ±5%
Apparent power (at 400 VAC)6.4 kVA
Max. assumed short-circuit current (Isc) (short-circuit current at connection point)65 kA
Power dissipation at nominal load and nominal clock frequency115 W
Integrated EMC filterNo
Motor connection
Derating of continuous output current depending on ambient temperature / At nominal clock frequency (4 kHz)No derating (up to 50°C)
Derating of continuous output current depending on ambient temperature / Other clock frequenciesThe derating curves are included in the installation instructions, which can be downloaded from www.br-automation.com.
Derating of continuous output current depending on installation elevation / Starting at 1000 m above sea level1%, per 100 m
Clock frequency / Min.2 kHz
Clock frequency / Max.16 kHz
Max. motor cable length / Shielded cable50 m
Max. motor cable length / Non-shielded cable100 m
Motor control profiles / Induction motorSensorless vector control: 1. Voltage controlled with constant torque → Standard mode Sensorless slip control: 1. With V/f characteristic curve for constant torque → Standard mode 2. With V/f characteristic curve for constant torque (up to 6 f-ranges) → Mode for individual special applications 3. With V/f characteristic curve for quadratically increasing torque → Energy-saving profile, e.g. for fans and pumps
Motor control profiles / Synchronous motorSensorless vector control: 1. Voltage controlled with constant torque → Standard mode
Nominal output current16.5 A
Max. transient current for 15 s, 3-phase318 A
Output frequency range0.1 to 599 Hz
Nominal clock frequency4 kHz
Main protective functions of inverterThermal protection against power stage overheating Protection against short circuits between motor phases, overcurrent between output phases and ground, overvoltages on the DC bus, exceeding the speed limit. Safety function for: Overvoltage and undervoltage of the mains supply, mains phase failure with 3-phase power supply
Brake chopper
Integrated dynamic brake transistorsYes
Min. resistance value (external)15 Ω
Max. output current26 A
24 VDC power supply
Input voltage24 VDC (-15%/+20%)
CurrentMax. 1.1 A
Available internal power supplies
Output voltage 24 VDC / Max. output current at 24 VDC100 mA
Output voltage 10 VDC / Max. output current at 10 VDC10 mA
Output voltage 24 VDC24 VDC (-15%/+20%)
Output voltage 10 VDC10 VDC (-0%/+10%)
Interfaces
POWERLINK / TypeType 3
Digital inputs
Quantity5
Nominal voltage24 VDC (max. 30 VDC)
Input circuitSource or sink
Sampling time8 ms ±0.7 ms
Safe input - STO (Safe Torque Off)
Input impedance / Current consumption16 mA
Electrical isolation / Input - ACOPOSinverterYes
Quantity2
Nominal voltage24 VDC (max. 30 VDC)
Input impedance1.5 kΩ
Analog inputs
Electrical isolation / Input - InputNo
Electrical isolation / Input - ACOPOSinverterYes
Input / VoltageAI1: 0 to 10 VDC
Input / Current0 to 20 mA (or 4 to 20 mA)
Input impedance / Voltage70 kΩ
Input impedance / Current<250 Ω
Quantity2
Basic accuracy±0.1 mA or 50 mV
Resolution12-bit
Sampling time1 ms
Digital outputs
Quantity1
Nominal voltage24 VDC -20%/+20%
Max. voltage30 VDC
Output circuitSource or sink
Sampling time1 ms
Max. current100 mA
Relay outputs
Variant / Relay 11 changeover contact
Quantity1
Nominal voltage24 VDC / 240 VAC
Switching current rangeMin. switching current: 5 mA at 24 VDC Max. Switching current: AC 240 V - 3 A DC 24 V - 2 A DC 240 V - 0.16 A
Analog outputs
Electrical isolation / Output - ACOPOSinverterYes
Electrical isolation / Output - OutputNo
Max. load impedance / Voltage≥2200 Ω
Max. load impedance / Current≥2200 Ω
Quantity1
Output0 to 10 V or 0 to 20 mA
Basic accuracy±100 mV or ±0.3 m
Resolution12-bit
Electrical properties
Energy efficiency (IE classification) / Power dissipation relative to continuous apparent powerIE2 (0, 25): 1.1% IE2 (0, 50): 1.3% IE2 (0, 100): 1.8% IE2 (50, 25): 1.2% IE2 (50, 50): 1.5% IE2 (50, 100): 2.2% IE2 (90, 50): 1.6% IE2 (90, 100): 2.5%
Energy efficiency (IE classification) / Nominal losses in standby mode0.1%
Operating conditions
Degree of protection per EN 61800-5-1IP20
Relative humidity per IEC 60068-2-3<95%, non-condensing No dripping water
Maximum installation elevation≤1000 m without derating 1000 to 4000 m with Derating
Max. pollution degree per IEC/EN 61800-5-12 (non-conductive pollution)
Ambient conditions per IEC 60721-3-3Class 3C3 and 3S2
Ambient conditions
Temperature / Operation-10 to 45°C without derating 45 to 60°C with derating
Temperature / Storage-25 to 60°C
Max. vibration resistanceOperation at switching frequency 2 or 4 kHz: Above +45°C reduce rated output current by 2.5%/°C EN 60721-3-3:1995 + A2:1997 Operation at switching frequency 8 or 16 kHz: Above +40°C reduce rated output current by 2.5%/°C EN 60721-3-3:1995 + A2:1997
Mechanical properties
Dimensions / Width90 mm
Dimensions / Height278 mm
Dimensions / Height without shield plate250 mm
Dimensions / Depth130 mm
Weight2.1 kg

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.