B&R 8I84T200037.01P-1

ACOPOSinverter P84, 3x 200 to 240 V, 0.37 kW, integrated EMC filter and brake chopper, shield plate included in delivery, POWERLINK interface.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

General information
Certifications / CEYes
Certifications / ULcULus E225616 Power conversion equipment
Certifications / KCYes
Motor power
Specified on nameplate, 3-phase0.37 kW 0.5 PS
Mains connection
Max. mains current with optional mains choke / At 230 VAC1.6 A
Mains current / At 200 VAC3.5 A
Mains current / At 240 VAC3.1 A
Mains input voltage, 3-phase3x 200 VAC -15% to 240 VAC +10%
Frequency50 to 60 Hz ±5%
Apparent power (at 240 VAC)1.3 kVA
Max. assumed short-circuit current (Isc) (short-circuit current at connection point)5 kA
Power dissipation at nominal load and nominal clock frequency46 W
Integrated EMC filterYes
Line-conducted and radiated emissions
With integrated filter / Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network)-
With integrated filter / Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network)≤10 m / ≤5 m
With integrated filter / Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system)≤10 m / ≤5 m
With add-on filter / Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network)≤50 m / ≤20 m
With add-on filter / Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network)≤100 m / ≤50 m
With add-on filter / Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system)≤100 m / ≤50 m
With add-on filter8I0FT012.300-1
Motor connection
Derating of continuous output current depending on ambient temperature / At nominal clock frequency (4 kHz or 2.5 kHz with higher inverter power)No derating (up to 50°C)
Derating of continuous output current depending on ambient temperature / Other clock frequenciesThe derating curves are included in the installation instructions, which can be downloaded from the website (www.br-automation.com).
Derating of continuous output current depending on installation elevation / Starting at 1000 m above sea level1%, per 100 m
Max. continuous output current (In) / At 230 VAC, 3-phase3 A
Nominal clock frequency / Min.1 kHz
Nominal clock frequency / Max.16 kHz
Braking torque / With braking resistorUp to 150% of the rated motor torque
Braking torque / Without braking resistor (typical value)30% of the rated motor torque
Max. motor cable length / Shielded cable50 m
Max. motor cable length / Non-shielded cable100 m
Motor control profiles / Induction motorFlux vector control (FVC) with encoder (voltage vector) (current vector) Flux vector control (SFVC) without encoder (voltage or current vector) Voltage/frequency ratio - V/f characteristic curve (2 or 5 points) ENA energy adjustment system for asymmetrical loads
Max. transient current for 60 s, 3-phase4.5 A
Max. transient current for 2 s, 3-phase4.9 A
Output frequency range0.5 to 599 Hz
Nominal clock frequency4 kHz
Short-term overload torque (typical value)170% of the motor's rated torque (typical value at ±10%) for 60 s 220% of the motor's rated torque (typical value at ±10%) for 2 s
Main protective functions of inverterThermal protection against power stage overheating Protection against short circuits between the motor phases, line phase failures, overcurrent between output phases and ground, overvoltages on the DC bus, interruptions in the control loop, exceeding the speed limit. Safety function for: Over- and undervoltage of the power supply system, line phase failure with 3-phase supply
Motor protectionThermal protection integrated in the inverter through continually calculating the l²t value while taking the speed into consideration: -The thermal state of the motor is stored when the frequency inverter is switched off. -The functionality can be adjusted according to the motor type (external cooling or self-cooling) using an operator interface. Protection against motor phase failures Protection provided by PTC sensors
Brake chopper
Integrated dynamic brake transistorsYes
Operating ratio for dynamic brake transistorsThe dynamic brake transistor is designed to tolerate the following values: -Nominal motor power continuously -150% of the nominal motor power for 60 s
Min. resistance value (external)44 Ω
24 VDC power supply
Input voltage24 VDC (min. 19 V, max. 30 V)
Power consumption30 W
Available internal power supplies
Output voltage 24 VDC / Max. output current at 24 VDC200 mA
Output voltage 10.5 VDC / Max. output current 10.5 VDC10 mA
Output voltage 24 VDC24 VDC (min. 21 V, max. 27 V)
Output voltage 10.5 VDC10.5 VDC ±5%
Safe input - Power removal
Switching threshold / Low<5 V
Switching threshold / High>15 V
Electrical isolation / Input - ACOPOSinverterYes
Electrical isolation / Input - InputNo
Quantity1
Nominal voltage24 VDC
Response time≤100 ms
Input impedance1.5 kΩ
Input circuitSink
Interfaces
POWERLINK / TypeType 3
Digital inputs
Electrical isolation / Input - ACOPOSinverterYes
Electrical isolation / Input - InputNo
Quantity6
Nominal voltage24 VDC
Input circuitSource or sink
Sampling time<2 ms ±0.5 ms
Input impedance3.5 kΩ
Analog inputs
Electrical isolation / Input - InputNo
Electrical isolation / Input - ACOPOSinverterYes
Input / Voltage±10 V
Input / Voltage/Current0 to 10 V or 0 to 20 mA
Input impedance / Voltage30 kΩ
Input impedance / Current242 Ω
Quantity2
Resolution±11 bits
Sampling time<2 ms ±0.5 ms
Relay outputs
Switching capacity / Max. / With resistive load (cos φ = 1 and L/R = 0 ms)2 A for 250 VAC or 30 VDC
Switching capacity / Max. / With inductive load (cos φ = 0.4 and L/R = 7 ms)1.5 A for 250 VAC or 30 VDC
Switching capacity / Min.3 mA for 24 VDC
Variant / Relay 11 NO contact and 1 NC contact with a common point
Variant / Relay 21 NO contact
Electrical isolation / Output - ACOPOSinverterYes
Electrical isolation / Output - OutputNo
Quantity2
Nominal voltage30 VDC / 250 VAC
Switching capacityMax. 2 A for 250 VAC or 30 VDC with resistive load
Response time (max.)<7 ms ±0.5 ms
Analog outputs
Electrical isolation / Output - ACOPOSinverterYes
Electrical isolation / Output - OutputNo
Max. load impedance / Voltage470 Ω
Max. load impedance / Current500 Ω
Quantity1
Output0 to 10 V or 0 to 20 mA
Update time<2 ms ±0.5 ms
Resolution10-bit
Operating conditions
Installation elevation above sea level0 to 1000 m
Degree of protection per EN 60529Upper part: IP21 and IP41 Lower part: IP54 (heat sink)
Ambient temperature-10 to 50°C
Max. ambient temperatureUp to 60°C
Relative humidity per IEC 60068-2-35 to 95%, non-condensing No dripping water
Maximum installation elevationUp to 3000 m
Max. pollution degree per IEC/EN 61800-5-12 (non-conductive pollution)
Ambient conditions per IEC 60721-3-3Class 3C1 and 3S2
Operating positionVertical mounting orientation ±10%
Ambient conditions
Temperature / Storage-25 to 70°C
Vibration / Operation3 to 13 Hz: 1.5 mm amplitude / 13 to 200 Hz: 1 g
Shock / Operation15 g, 11 ms
Mechanical properties
Dimensions / Width130 mm
Dimensions / Height230 mm
Dimensions / Depth175 mm
Weight3 kg