IAC

B&R 8I86T401100.00-000

Base device for ACOPOSinverter P86, 3x 380 to 480 V, 11 kW, EMC filter and brake chopper. Order number - ACOPOSinverter P86: 8I86T401100.0P-100: Inverter with POWERLINK communication card

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

General information
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ULcULus E225616 Power conversion equipment
Motor power
Specified on nameplate11 kW (15 HP)
Mains connection
Max. mains current with optional mains choke / At 380 VAC21.9 A
Max. mains current with optional mains choke / At 480 VAC17.7 A
Mains current / At 380 VAC34.7 A
Mains current / At 480 VAC27.7 A
Power dissipation / External cooling313 W
Power dissipation / Natural cooling50 W
Mains input voltage3x 380 VAC -15% to 480 VAC +10%
Frequency50 to 60 Hz ±5%
Apparent power (at 480 VAC)23 kVA
Max. assumed short-circuit current (Isc) (short-circuit current at connection point)22 kA
Inrush currentMax. 80.8 A
Integrated EMC filterYes
Line-conducted and radiated emissions
With integrated filter / Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network)-
With integrated filter / Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system)20 m
With add-on filter / Motor cable length per IEC/EN 61800-3 Cat. C1 environment 1 (public power network)-
With add-on filter / Motor cable length per IEC/EN 61800-3 Cat. C2 environment 1 (public power network)C2 level at 4 kHz with 50 m cable
With add-on filter / Motor cable length per IEC/EN 61800-3 Cat. C3 environment 2 (industrial power system)C3 level at 4 kHz with 100 m cable
With add-on filter8I0FT050.200-1
Motor connection
Derating of continuous output current depending on ambient temperature / At nominal clock frequency (4 kHz or 2.5 kHz with higher inverter power)No derating (up to 50°C)
Derating of continuous output current depending on ambient temperature / Other clock frequenciesThe derating curves are included in the installation instructions, which can be downloaded from www.br-automation.com.
Derating of continuous output current depending on installation elevation / Starting at 1000 m above sea level1%, per 100 m
Clock frequency / Min.2 kHz
Clock frequency / Max.16 kHz
Max. motor cable length / Shielded cable150 m
Max. motor cable length / Non-shielded cable300 m
Motor control profiles / Induction motorSensorless vector control: 1. Voltage controlled with constant torque → Default mode 2. Voltage controlled with variable torque → Energy-saving mode, e.g. for fans and pumps Vector control with encoder: 1. Current-controlled with constant torque → Default mode Sensorless slip control: 1. With V/f characteristic curve for constant torque → Default mode 2. With V/f characteristic curve for constant torque (up to 6 f ranges) → Mode for individual special applications 3. With V/f characteristic curve for quadratically increasing torque → Energy-saving mode, e.g. for fans and pumps
Motor control profiles / Synchronous motorSensorless vector control: 1. Voltage controlled with constant torque → Default mode Vector control with encoder: 1. Current-controlled with constant torque → Default mode
Nominal output current24 A
Max. transient current for 60 s36 A
Max. transient current for 2 s43 A
Output frequency range0.1 to 599 Hz
Nominal clock frequency4 kHz
Main protective functions of inverterThermal protection against power stage overheating Protection against short circuits between motor phases, overcurrent between output phases and ground, overvoltages on the DC bus, exceeding the speed limit. Safety function for: Overvoltage and undervoltage of the mains supply, mains phase failure with 3-phase power supply
Brake chopper
Integrated dynamic brake transistorsYes
Min. resistance value (external)16 Ω
24 VDC power supply
Input voltage24 VDC (min. 20.4 VDC, max. 27 VDC)
CurrentMax. 0.8 A
Available internal power supplies
Output voltage 24 VDC / Max. output current at 24 VDCMax. 200 mA
Output voltage 10 VDC / Max. output current at 10 VDCMax. 10 mA
Output voltage 24 VDC24 VDC (min. 20.4 VDC, max. 27 VDC)
Output voltage 10 VDC10.5 VDC ±5%
Interfaces
POWERLINK / TypeType 3
Digital inputs
Switching threshold / LowSource: <0.5 V Sink: >16 V
Switching threshold / HighSource: >11 V Sink: <10 V
Electrical isolation / Input - ACOPOSinverterYes
Electrical isolation / Input - InputNo
Quantity5
Nominal voltage24 VDC (max. 30 VDC)
Input circuitSource or sink
Sampling time2 ms ±0.5 ms
Input impedance4.4 kΩ
Safe input - STO (Safe Torque Off)
Switching threshold / Low<5 V
Switching threshold / High>11 V
Electrical isolation / Input - ACOPOSinverterYes
Electrical isolation / Input - InputNo
Quantity2
Nominal voltage24 VDC (max. 30 VDC)
Input impedance2.2 kΩ
Input circuitSource
Event counters
Switching threshold / Low<0.6 V
Switching threshold / High>2.5 V
Quantity1
Nominal voltage24 VDC (max. 30 VDC)
Input frequency0 to 30 kHz
Input circuitSource
Sampling time5 ms ±1 ms
Analog inputs
Electrical isolation / Input - InputNo
Electrical isolation / Input - ACOPOSinverterYes
Input / VoltageAI1: 0 to 10 VDC AI2: -10 to 10 VDC
Input / CurrentAI1: 0 to 20 mA
Input impedance / VoltageAI1: 31.5 kΩ AI2: 20 kΩ
Input impedance / Current250 Ω
Quantity2
Nonlinearity±0.15%
Basic accuracy±0.6% with temperature fluctuation of 60°C
Resolution12-bit
Sampling time1 ms ±1 ms
Digital outputs
Quantity2
Nominal voltage24 VDC -15%/+20%
Max. voltage30 VDC
Output circuitSource or sink
Sampling time2 ms ±0.5 ms
Max. current100 mA
Relay outputs
Execution / Relay 11 changeover contact
Execution / Relay 21 normally open contact
Electrical isolation / Output - ACOPOSinverterYes
Electrical isolation / Output - OutputNo
Quantity2
Nominal voltage30 VDC / 250 VAC
Switching current rangeMin. switching current: 5 mA at 24 VDC Max. switching current: R1: At cos φ = 1: Max. 3 A / At cos φ = 0.4: Max. 2 A R2: At cos φ = 1: Max. 5 A / At cos φ = 0.4: Max. 2 A
Response time (max.)5 ms ±0.5 ms
Analog outputs
Electrical isolation / Output - ACOPOSinverterYes
Electrical isolation / Output - OutputNo
Max. load impedance / Voltage470 Ω
Max. load impedance / Current500 Ω
Quantity1
Output0 to 10 VDC or 0 to 20 mA
Nonlinearity±0.2%
Basic accuracy±1% with temperature fluctuation of 60°C
Sampling time5 ms ±1 ms
Resolution10-bit
Electrical properties
Energy efficiency (IE classification) / Power dissipation relative to continuous apparent powerIE2 (10, 25): 0.7% (3x 380 VAC), 0.5% (3x 480 VAC) IE2 (50, 25): 0.6% (3x 380 VAC), 0.5% (3x 480 VAC) IE2 (10, 50): 0.9% (3x 380 VAC), 0.7% (3x 480 VAC) IE2 (50, 50): 0.8% (3x 380 VAC), 0.7% (3x 480 VAC) IE2 (90, 50): 1% (3x 380 VAC), 0.9% (3x 480 VAC) IE2 (10, 100): 1.6% (3x 380 VAC), 1.3% (3x 480 VAC) IE2 (50, 100): 1.5% (3x 380 VAC), 1.3% (3x 480 VAC) IE2 (90, 100): 1.9% (3x 380 VAC), 1.7% (3x 480 VAC)
Energy efficiency (IE classification) / Nominal losses in standby mode17 W (3x 380 VAC), 19 W (3x 480 VAC)
Operating conditions
Degree of protection per EN 61800-5-1IP20
Degree of protection per EN 60529IP20
Max. relative humidity per EN/IEC 60721-3-3 class 3K35 to 95%, non-condensing
Maximum installation elevation≤1000 m without derating 1000 to 3000 m with Derating
Max. pollution degree per IEC/EN 61800-5-12 (non-conductive pollution)
Ambient conditions per IEC 60721-3-3Class 3C3 and 3S3
Operating positionVertical mounting orientation ±10°
Ambient conditions
Temperature / Operation-15 to 50°C without derating 50 to 60°C with derating
Temperature / Storage-40 to 70°C
Max. vibration resistance1 gn 9 to 200 Hz EN/IEC 60721-3-3 class 3M3 1.5 mm peak to peak 2 to 19 Hz EN/IEC 60721-3-3 class 3M3
Max. shock resistance15 gn (duration = 11 ms) per EN/IEC 60721-3-3 class 3M3
Mechanical properties
Dimensions / Width180 mm
Dimensions / Height385 mm
Dimensions / Depth249 mm
Weight9.5 kg

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.