IAC

B&R 8KSJ82.ee020ff00-h

Synchronous motor, external cooling, water-cooled, flange mounting, B-side foot mounting possible, size 8, length 2, nominal speed 2000 rpm.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

Replacing or upgrading a servo component?

Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Motor
Nominal speed nN [rpm]2000
Number of pole pairs3
Nominal torque Mn [Nm]165
Nominal power PN [W]34558
Nominal current IN [A]67
Stall torque M0 [Nm]180
Stall current I0 [A]73
Maximum torque Mmax [Nm]340
Maximum current Imax [A]155
Maximum speed nmax [rpm]4300
Torque constant KT [Nm/A]2.56
Voltage constant KE [V/1000 rpm]163
Stator resistance R2ph [Ω]0.196
Stator inductance L2ph [mH]6
Electrical time constant tel [ms]30.6
Thermal time constant ttherm [min]16.1
Moment of inertia J [kgcm²]450
Weight without brake m [kg]110
Holding brake
Holding torque of brake MBr [Nm]200
Mass of brake [kg]0
Moment of inertia of brake JBr [kgcm²]0
Recommendations
ACOPOS 8Vxxxx.xx...128M
ACOPOSmulti 8BVIxxxx...0880
Cross section for B&R motor cables [mm²]0
Connector typeTerminal box

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.