IAC

B&R 8KSL84.ee030ff00-h

Synchronous motor, external cooling, axial fan, flange mounting, B-side foot mounting possible, size 8, length 4, nominal speed 3000 rpm.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

Replacing or upgrading a servo component?

Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Motor
Nominal speed nN [rpm]3000
Number of pole pairs3
Nominal torque Mn [Nm]130
Nominal power PN [W]40841
Nominal current IN [A]74
Stall torque M0 [Nm]175
Stall current I0 [A]98
Maximum torque Mmax [Nm]405
Maximum current Imax [A]250
Maximum speed nmax [rpm]4300
Torque constant KT [Nm/A]1.84
Voltage constant KE [V/1000 rpm]120
Stator resistance R2ph [Ω]0.068
Stator inductance L2ph [mH]2.3
Electrical time constant tel [ms]40
Thermal time constant ttherm [min]23.8
Moment of inertia J [kgcm²]580
Weight without brake m [kg]125
Holding brake
Holding torque of brake MBr [Nm]200
Mass of brake [kg]0
Moment of inertia of brake JBr [kgcm²]0
Recommendations
ACOPOS 8Vxxxx.xx...128M
ACOPOSmulti 8BVIxxxx...1650
Cross section for B&R motor cables [mm²]0
Connector typeTerminal box

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.