B&R 8PM001.00-1
8-pin female Intercontec motor connector, crimping range 4x 0.5-2.5 mm² + 4x 0.06-1.0 mm², for cables 9-14 mm, IP67
Lifecycle & replacement
Lifecycle status not indexed
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
General information
| Insulator | PA 6.6 / PBT, UL 94/V0 listed |
| Contacts | 8 (4 power and 4 signal contacts) |
| Protective ground connection on housing | Per VDE 0627 |
Electrical properties
| Power contacts / Contact resistance | <3 mΩ |
| Power contacts / Nominal voltage | 630 VAC / VDC |
| Power contacts / Nominal current | 30 A |
| Power contacts / Test voltage (L - L) | 6000 V |
| Signal contacts / Contact resistance | <5 mΩ |
| Signal contacts / Nominal voltage | 250 VAC / VDC |
| Signal contacts / Nominal current | 10 A |
| Signal contacts / Test voltage (L - L) | 2500 V |
| Overvoltage category | 3 |
Operating conditions
| Pollution degree per EN 61800-5-1 | 3 |
| Degree of protection per EN 60529 | IP67 when connected |
Ambient conditions
| Temperature / Operation | -20 to 130°C |
| Elevation / Operation | Up to 2000 m |
Mechanical properties
| Housing / Material | Zinc die-casting / Brass, nickel-plated |
| Crimping range | 4x 0.5 - 2.5 mm² + 4 x 0.06 - 1 mm² |
| Gasket | FPM / HNBR |
| Connector size | Size 1 |
| Mating cycles | >50 |
| Cable terminals | 9.5 - 14.5 mm |
Vendor information
| Manufacturer | Intercontec (www.intercontec.biz) |
| Manufacturer's product ID | BSTA 108 FR 19 58 0036 000 |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Manuals
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.