IAC

B&R 8V128M.00-2

Modular mechanical design using plug-in modules Integrated line filter Integrated or optional external braking resistor Integrated electronic restart inhibit ACOPOS servo drive, 3x 400-480 V, 128 A, 64 kW, integrated line filter, braking resistor, DC bus power supply unit and electronic safe restart interlock

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

Replacing or upgrading a servo component?

Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

General information
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)Non-compliant
Certifications / Functional safetyYes
Certifications / ULcULus E225616 Power conversion equipment
Certifications / KCYes
B&R ID code0x12F3
Slots for plug-in modules4
Mains connection
Permissible network configurationsTT, TN
Mains input voltage3x 400 VAC to 480 VAC ±10%
Frequency50 / 60 Hz ±4%
Installed loadMax. 98 kVA
Inrush current at 400 VAC26 A
Switch-on interval>10 s
Integrated line filter per EN 61800-3, category C3Yes
Power dissipation at device nominal power without braking resistorApprox. 3200 W
DC bus connection
DC bus capacitance6600 µF
24 VDC power supply
Current consumption at 24 VDC / Mains input voltage applied-
Current consumption at 24 VDC / Mains input voltage not appliedMax. 5.7 A + 1.4 * (Current for motor holding brake + Current on 24 VDC output)
DC bus power supply unit / Switch-on voltage455 VDC
Input voltage24 VDC +25% / -20%
Input capacitance32,800 µF
24 VDC output
Output voltage / Mains input voltage applied22 to 24 VDC
Output voltage / Mains input voltage not applied16.7 to 30 VDC
Output currentMax. 0.5 A
Motor connection
Reduction of continuous current depending on ambient temperature / Mains input voltage: 400 VAC / Switching frequency 5 kHzNo reduction
Reduction of continuous current depending on ambient temperature / Mains input voltage: 400 VAC / Switching frequency 10 kHz1.65 Aeff per °C (starting at 52°C)
Reduction of continuous current depending on ambient temperature / Mains input voltage: 400 VAC / Switching frequency 20 kHz1.65 Aeff per °C (starting at 12°C)
Reduction of continuous current depending on ambient temperature / Mains input voltage: 480 VAC / Switching frequency 5 kHzNo reduction
Reduction of continuous current depending on ambient temperature / Mains input voltage: 480 VAC / Switching frequency 10 kHz1.65 Aeff per °C (starting at 36°C)
Reduction of continuous current depending on ambient temperature / Mains input voltage: 480 VAC / Switching frequency 20 kHz1.65 Aeff per °C (starting at 10°C)
Reduction of continuous current depending on installation elevation / Starting at 500 m above sea level12.8 Aeff per 1000 m
Protective measures / Overload protectionYes
Protective measures / Short-circuit and ground fault protectionYes
Terminal connection cross section / Flexible and fine-stranded wires / With wire end sleeve10 to 70 mm²
Terminal connection cross section / Approbation data / UL/C-UL-US6 to 2/0 AWG
Terminal connection cross section / Approbation data / CSA6 to 2/0 AWG
Quantity1
Continuous current128 Aeff
Peak current300 Aeff
Nominal switching frequency5 kHz
Possible switching frequencies5 / 10 / 20 kHz
Insulation stress of the connected motor per IEC TS 60034-25:2004Limit value curve A
Max. motor line length25 m
Max. output frequency598 Hz
Motor holding brake connection
Response threshold for open-circuit monitoringApprox. 210 mA
Max. output current3 A
Max. number of switching cyclesApprox. 80,000
Braking resistor
Peak power int./ext.8.5 / 250 kW
Continuous power int./ext.0.24 / 24 kW
Minimum braking resistance (ext.)2.5 Ω
Rated current of built-in fuse30 A (fast-acting)
Limit switch and reference inputs
Electrical isolation / Input - ACOPOSYes
Electrical isolation / Input - InputNo
Input voltage / Nominal24 VDC
Input voltage / Maximum30 VDC
Switching threshold / Low<5 V
Switching threshold / High>15 V
Quantity3
CircuitSink
Input current at nominal voltageApprox. 4 mA
Switching delayMax. 2.0 ms
Modulation compared to ground potentialMax. ±38 V
Enable inputs
Electrical isolation / Input - ACOPOSYes
Input voltage / Nominal24 VDC
Input voltage / Maximum30 VDC
Switching threshold / Low<5 V
Switching threshold / High>15 V
Switching delay / Enable 0 → 1, ready for PWMMax. 100 µs
Switching delay / Enable 1 → 0, PWM offMax. 2.0 ms
Quantity1
CircuitSink
Input current at nominal voltageApprox. 30 mA
Modulation compared to ground potentialMax. ±38 V
OSSD signal connectionsNot permitted
Trigger inputs
Electrical isolation / Input - ACOPOSYes
Electrical isolation / Input - InputNo
Input voltage / Nominal24 VDC
Input voltage / Maximum30 VDC
Switching threshold / Low<5 V
Switching threshold / High>15 V
Switching delay / Rising edge52 µs ±0.5 µs (digitally filtered)
Switching delay / Falling edge53 µs ±0.5 µs (digitally filtered)
Quantity2
CircuitSink
Input current at nominal voltageApprox. 10 mA
Modulation compared to ground potentialMax. ±38 V
Electrical properties
Energy efficiency (IE classification) / Power dissipation relative to continuous apparent powerIE2 (10,25) 0.7% IE2 (50,25) 0.8% IE2 (10,50) 0.9% IE2 (50,50) 1% IE2 (90,50) 1.2% IE2 (10,100) 1.6% IE2 (50,100) 1.9% IE2 (90,100) 2.4%
Energy efficiency (IE classification) / Nominal losses in standby mode38.6 W
Discharge capacitance5.4 µF
Operating conditions
Permissible mounting orientations / Hanging verticallyYes
Permissible mounting orientations / Horizontal, face upYes
Permissible mounting orientations / Standing horizontallyNo
Installation elevation above sea level / Nominal0 to 500 m
Installation elevation above sea level / Maximum2000 m
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1II
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Nominal5 to 40°C
Temperature / Operation / Maximum55°C
Temperature / Storage-25 to 55°C
Temperature / Transport-25 to 70°C
Relative humidity / Operation5 to 85%
Relative humidity / Storage5 to 95%
Relative humidity / TransportMax. 95% at 40°C
Mechanical properties
Dimensions / Width402 mm
Dimensions / Height460 mm
Dimensions / Depth295 mm
Weight33.8 kg

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.