B&R 9A0100.11

24 VDC input voltage 24 VDC output voltage Industrial standard installation Communication via serial interface Status indicators Deep discharge protection Short circuit protection Maintenance free battery units The UPS module is used to supply power for systems which cannot be connected directly to the +24 VDC power mains for safety reasons because a power failure could cause data to be lost. The UPS module allows the load system (e.g. industrial PC) to be shut down securely without losing data if a power failure occurs.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

General information
Certifications / CEYes
Certifications / UKCAYes
Certifications / ULcULus E115267 Industrial control equipment
Interfaces
COM1 / TypeRS232
COM1 / VariantDSUB, 9-pin
Support
Operating systems / Windows XP ProfessionalYes
Operating systems / Windows XP EmbeddedYes
Operating systems / Windows NT 4.0Yes
Operating systems / Windows MEYes
Operating systems / Windows 2000Yes
Operating systems / Windows 98Yes
Operating systems / Windows 95Yes
Electrical properties
Output during battery operation / Voltage range21 to 26.8 VDC (40°C) or 28.2 VDC (0°C)
Output during battery operation / Rated voltage value24 VDC
Output during battery operation / Max. output current8 A (load side)
Output during battery operation / Power failure bypassMax. 20 minutes at 150 W load (with battery 9A0100.12, 24 V / 7.2 Ah)
Output during battery operation / Switching threshold for mains/battery operation18 V at 20 to 30 VDC input 21.5 V at 23.5 to 30 VDC input
Output during mains operation / Voltage range20 to 30 VDC or 23.5 - 30 VDC depending on the set changeover threshold
Output during mains operation / Rated voltage value24 VDC
Output during mains operation / Max. output current8 A
Input during mains operation / Power failure bypassMax. 20 min at 150 W load
Input during mains operation / Voltage range20 to 30 VDC at a switching threshold of 18 V 23.5 to 30 VDC at a switching threshold of 21.5 V
Input during mains operation / Rated voltage value24 VDC
Input during mains operation / Switching threshold for rechargeable battery18 V
Battery charging data / Charging clearing voltage27.6 VDC
Battery charging data / Charging currentFrom 0.88 A to 2.88 A depending on type
FuseYes, for mains, battery, battery charger
Deep discharge protectionYes, cutoff threshold 21 VDC
Reverse polarity protectionYes, for mains and battery
Short-circuit proofYes
Overvoltage category per EN 61131-2II
Ambient conditions
Temperature / Operation0 to 55°C
Temperature / Storage-20 to 60°C
Temperature / Transport-20 to 60°C
Relative humidity / Operation5 to 95%, non-condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Vibration / OperationMax. 9 to 200Hz and 1g (9.8 m/s² 0-peak)
Vibration / StorageMax. 2 to 500Hz and 4g (39.2 m/s² 0-peak)
Vibration / TransportMax. 2 to 500Hz and 4g (39.2 m/s² 0-peak)
Shock / Operation15 g, 11 ms
Shock / Storage100 g, 6 ms
Shock / Transport100 g, 6 ms
Elevation / OperationMax. 3000 m
Mechanical properties
Dimensions / Width185 mm
Dimensions / Height115 mm
Dimensions / Depth69 mm
WeightApprox. 1100 g