Yaskawa CIMR-AU2A0012FAA
A1000 - Dynamic Braking Resistor 3 Percent
Rated for 3% duty cycle over a 100-second interval. Approximate braking torque for each rating is listed. These resistors are designed in NEMA 1 enclosures for separate panel mounting. 200-400V, 3-Phase | 380-480V, 3-Phase 200-240V, 3-Phase Dynamic Braking Resistor, 3% Duty Cycle
Lifecycle & replacement
Yaskawa's published discontinuation lists (checked 2026-09-01) do not assign a lifecycle status to this part number.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Checked against: Yaskawa America Support By Product - Inverter Drives; Yaskawa America Support By Product - Servo Amplifiers; Yaskawa America Support By Product - Servomotors; Yaskawa America Support By Product - Machine Controllers; Yaskawa America Support By Product - PLC Controllers; Yaskawa America Support By Product - Spindle Drives; Yaskawa America Support By Product - Spindle Motors; Yaskawa product page carrying the verbatim definition of Legacy.
Part number breakdown
Decoded from YASKAWA AC Drive-A1000 High Performance Vector Control Drive Technical Manual (SIEP C710616 41H) (SIEPC71061641), 1.3 Model Number and Nameplate Check, p.35, 36. Codes the document does not list are shown as not documented.
- SeriesADrive A1000 SeriesSource: SIEPC71061641 p.35, 36
- Region codeUUSASource: SIEPC71061641 p.35, 36
- Voltage class23-phase, 200-240 VacSource: SIEPC71061641 p.35, 36
- Customized specificationsAStandard modelSource: SIEPC71061641 p.35, 36
- Drive model (rated output current code)2A00122A0012: max. motor capacity 2.2 kW (3 HP), rated output current 11 A, heavy duty ratingratedOutputKw: 2.2ratedOutputHp: 3ratedCurrentA: 11duty: heavySource: SIEPC71061641 p.36, 37, 38, 39, 40, 529, 530, 531, 532, 533, 534, 535, 536, 537
- Enclosure typeFIP20/NEMA 1, UL Type 1Source: SIEPC71061641 p.35, 36
- Environmental specificationAStandardSource: SIEPC71061641 p.35, 36
Technical specifications
A1000 Dynamic Braking Resistor 3 Percent
| Heavy Duty - Rated Current (A) | 11 |
| Heavy Duty - Nominal HP | 3 |
| 3% DB Resistor 3 - Qty Required | 1 |
| 3% DB Resistor 3 - Resistance (Ohms) (Each) | 70 |
| 3% DB Resistor 3 - Power (Watts) (Each) | 150 |
| 3% DB Resistor 3 - Approx. Braking Torque (%) | 120 |
| 3% DB Resistor 3 - Dynamic Braking Resistor Part Number | R7503 |
A1000 Dynamic Braking Resistor 3 Percent [A1000 - Dynamic Braking Resistor 3 Percent]
| Normal Duty - Rated Current (A) | 12 |
| Normal Duty - Nominal HP | 3 |
| 3% DB Resistor 3 - Qty Required | 1 |
| 3% DB Resistor 3 - Resistance (Ohms) (Each) | 62 |
| 3% DB Resistor 3 - Power (Watts) (Each) | 150 |
| 3% DB Resistor 3 - Approx. Braking Torque (%) | 100 |
| 3% DB Resistor 3 - Dynamic Braking Resistor Part Number | R7510 |
A1000 Dynamic Braking Resistor 10 Percent
| Normal Duty - Nominal HP | 3 |
| Braking Unit - Qty | Built-in |
| 10% DB Resistor - Qty Required | 1 |
| 10% DB Resistor - Resistance (Ohms) (Each) | 38 |
| 10% DB Resistor - Approx. Braking Torque (%) | 100 |
| Minimum Resistance (Ohms) 2 | 16 |
| Con figuration 3 | Single |
| Braking Unit - Part Number CDBR- | Built-in |
| 10% DB Resistor - Dynamic Braking Resistor Part Number | URS000267 |
A1000 Dynamic Braking Resistor 10 Percent [A1000 - Dynamic Braking]
| Heavy Duty - Nominal HP | 3 |
| Braking Unit - Qty | Built-in |
| 10% DB Resistor - Qty Required | 1 |
| 10% DB Resistor - Resistance (Ohms) (Each) | 42 |
| 10% DB Resistor - Approx. Braking Torque (%) | 150 |
| Minimum Resistance (Ohms) 2 | 16 |
| Con figuration 3 | Single |
| Braking Unit - Part Number CDBR- | Built-in |
| 10% DB Resistor - Dynamic Braking Resistor Part Number | URS000279 |
Documentation & CAD
Files hosted by Yaskawa; links open the official document or download page. 3D CAD requires a free Yaskawa login.
Manuals
2D drawings
Certificates
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.
Specifications compiled from official Yaskawa product documentation. Always confirm against the datasheet for your exact unit and revision.