IAC

Yaskawa CIMR-PU5A0004

P1000 DC Reactors

1 "Large" P1000 chassis have a built-in DC link reactor equivalent to 3% line reactance. 240 VAC ratings are shown with 3% added AC reactance for 6% total.

Lifecycle & replacement

Lifecycle status not published

Yaskawa's published discontinuation lists (checked 2026-09-01) do not assign a lifecycle status to this part number.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Checked against: Yaskawa America Support By Product - Inverter Drives; Yaskawa America Support By Product - Servo Amplifiers; Yaskawa America Support By Product - Servomotors; Yaskawa America Support By Product - Machine Controllers; Yaskawa America Support By Product - PLC Controllers; Yaskawa America Support By Product - Spindle Drives; Yaskawa America Support By Product - Spindle Motors; Yaskawa product page carrying the verbatim definition of Legacy.

Technical specifications

P1000 DC Reactors
Nominal HP3
Rated DC Current (A)4
3% Enclosed Reactor - Inductance (μH)12000
3% Enclosed Reactor - Weight (lb)9
5% Enclosed Reactor - Inductance (μH)25000
5% Enclosed Reactor - Weight (lb)11
3% Enclosed Reactor - Reactor Part NumberURX000207
5% Enclosed Reactor - Reactor Part NumberURX000216
P1000 Load Reactors
Nominal HP3
Nominal 3% Impedance - Reactor Rated Current (A)4
Nominal 3% Impedance - Inductance (μH)9000
Nominal 3% Impedance - Weight (lb)12
Nominal 3% Impedance - Enclosed Part Number05P00620-0022
P1000 Load Reactors [P1000 Load Reactors]
Nominal HP3
Nominal 5% Impedance - Reactor Rated Current (A)4
Nominal 5% Impedance - Inductance (μH)12000
Nominal 5% Impedance - Weight (lb)13
Nominal 5% Impedance - Enclosed Part Number05P00620-0023

Documentation & CAD

Files hosted by Yaskawa; links open the official document or download page. 3D CAD requires a free Yaskawa login.

Certificates

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.

Specifications compiled from official Yaskawa product documentation. Always confirm against the datasheet for your exact unit and revision.