Yaskawa CIMR-PW4A0004
iQpump1000 - DC Reactors
EMC Filters - may be used on the input of the drive to attenuate possible drive-generated noise. Filters should always be mounted as close to the drive as possible.
Lifecycle & replacement
Yaskawa's published discontinuation lists (checked 2026-09-01) do not assign a lifecycle status to this part number.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Checked against: Yaskawa America Support By Product - Inverter Drives; Yaskawa America Support By Product - Servo Amplifiers; Yaskawa America Support By Product - Servomotors; Yaskawa America Support By Product - Machine Controllers; Yaskawa America Support By Product - PLC Controllers; Yaskawa America Support By Product - Spindle Drives; Yaskawa America Support By Product - Spindle Motors; Yaskawa product page carrying the verbatim definition of Legacy.
Technical specifications
iQpump1000 - DC Reactors
| Nominal HP | 1.5 |
| Rated DC Current (A) | 9 |
| 3% Enclosed Reactor - Inductance (μH) | 15000 |
| 3% Enclosed Reactor - Weight (lb) | 9 |
| 3% Enclosed Reactor - Reactor Part Number | URX000217 |
iQpump1000 - DC Reactors [iQpump1000 - DC Reactors]
| Nominal HP | 2 |
| Rated DC Current (A) | 9 |
| 3% Enclosed Reactor - Inductance (μH) | 15000 |
| 3% Enclosed Reactor - Weight (lb) | 9 |
| 3% Enclosed Reactor - Reactor Part Number | URX000217 |
iQpump1000 - DC Reactors [iQpump1000 - DC Reactors] (2)
| Nominal HP | 1.5 |
| Rated DC Current (A) | 9 |
| 5% Enclosed Reactor - Inductance (μH) | 25000 |
| 5% Enclosed Reactor - Weight (lb) | 11 |
| 5% Enclosed Reactor - Reactor Part Number | URX000216 |
iQpump1000 - DC Reactors [iQpump1000 - DC Reactors] (3)
| Nominal HP | 2 |
| Rated DC Current (A) | 9 |
| 5% Enclosed Reactor - Inductance (μH) | 25000 |
| 5% Enclosed Reactor - Weight (lb) | 11 |
| 5% Enclosed Reactor - Reactor Part Number | URX000216 |
iQpump1000 - EMC Filters
| Nominal HP | 2 |
| Schaffner Filters - Qty Required | 1 |
| Schaffner Filters - Rated Current (A) | 10 |
| EPCOS Filters 1 - Qty Required | 1 |
| EPCOS Filters 1 - Rated Current (A) | 16 |
| Schaffner Filters - Schaffner Filter Part Number | FS5972-10-07 |
| EPCOS Filters 1 - EPCOS Filter Part Number | UFI000178 |
iQpump1000 - Load Reactors
| Nominal HP | 1.5 |
| Nominal 3% Impedance - Reactor Rated Current (A) | 4 |
| Nominal 3% Impedance - Inductance (μH) | 6500 |
| Nominal 3% Impedance - Weight (lb) | 11 |
| Nominal 3% Impedance - Enclosed Part Number | 05P00620-0021 |
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors]
| Nominal HP | 2 |
| Nominal 3% Impedance - Reactor Rated Current (A) | 4 |
| Nominal 3% Impedance - Inductance (μH) | 6500 |
| Nominal 3% Impedance - Weight (lb) | 11 |
| Nominal 3% Impedance - Enclosed Part Number | 05P00620-0021 |
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors] (2)
| Nominal HP | 1.5 |
| Nominal 5% Impedance - Reactor Rated Current (A) | 4 |
| Nominal 5% Impedance - Inductance (μH) | 12000 |
| Nominal 5% Impedance - Weight (lb) | 13 |
| Nominal 5% Impedance - Enclosed Part Number | 05P00620-0023 |
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors] (3)
| Nominal HP | 2 |
| Nominal 5% Impedance - Reactor Rated Current (A) | 4 |
| Nominal 5% Impedance - Inductance (μH) | 12000 |
| Nominal 5% Impedance - Weight (lb) | 13 |
| Nominal 5% Impedance - Enclosed Part Number | 05P00620-0023 |
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors] (4)
| Nominal HP | 1 |
| Enclosed AC Reactor - Current (A) | 4.8 |
| Enclosed AC Reactor - Inductance (μH) | 2.300 |
| Enclosed AC Reactor - Weight (lb) | 1.7 |
| Enclosed AC Reactor - Part Number | URX000410 |
Documentation & CAD
Files hosted by Yaskawa; links open the official document or download page. 3D CAD requires a free Yaskawa login.
Datasheets & catalogs
Certificates
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.
Specifications compiled from official Yaskawa product documentation. Always confirm against the datasheet for your exact unit and revision.