IAC

Yaskawa CIMR-PW5A0003

iQpump1000 - DC Reactors

Lifecycle & replacement

Lifecycle status not published

Yaskawa's published discontinuation lists (checked 2026-09-01) do not assign a lifecycle status to this part number.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Checked against: Yaskawa America Support By Product - Inverter Drives; Yaskawa America Support By Product - Servo Amplifiers; Yaskawa America Support By Product - Servomotors; Yaskawa America Support By Product - Machine Controllers; Yaskawa America Support By Product - PLC Controllers; Yaskawa America Support By Product - Spindle Drives; Yaskawa America Support By Product - Spindle Motors; Yaskawa product page carrying the verbatim definition of Legacy.

Technical specifications

iQpump1000 - DC Reactors
Nominal HP1/2
Rated DC Current (A)1
3% Enclosed Reactor - Inductance (μH)60000
3% Enclosed Reactor - Weight (lb)TBD
3% Enclosed Reactor - Reactor Part NumberTBD
iQpump1000 - DC Reactors [iQpump1000 - DC Reactors]
Nominal HP3/4
Rated DC Current (A)2
3% Enclosed Reactor - Inductance (μH)50000
3% Enclosed Reactor - Weight (lb)9
3% Enclosed Reactor - Reactor Part NumberURX000215
iQpump1000 - DC Reactors [iQpump1000 - DC Reactors] (2)
Nominal HP1
Rated DC Current (A)2
3% Enclosed Reactor - Inductance (μH)20000
3% Enclosed Reactor - Weight (lb)TBD
3% Enclosed Reactor - Reactor Part NumberTBD
iQpump1000 - DC Reactors [iQpump1000 - DC Reactors] (3)
Nominal HP1.5
Rated DC Current (A)4
3% Enclosed Reactor - Inductance (μH)15000
3% Enclosed Reactor - Weight (lb)9
3% Enclosed Reactor - Reactor Part NumberURX000217
iQpump1000 - DC Reactors [iQpump1000 - DC Reactors] (4)
Nominal HP2
Rated DC Current (A)4
3% Enclosed Reactor - Inductance (μH)15000
3% Enclosed Reactor - Weight (lb)9
3% Enclosed Reactor - Reactor Part NumberURX000217
iQpump1000 - DC Reactors [iQpump1000 - DC Reactors] (5)
Nominal HP1/2
Rated DC Current (A)1
5% Enclosed Reactor - Inductance (μH)80000
5% Enclosed Reactor - Weight (lb)TBD
5% Enclosed Reactor - Reactor Part NumberTBD
iQpump1000 - DC Reactors [iQpump1000 - DC Reactors] (6)
Nominal HP3/4
Rated DC Current (A)2
5% Enclosed Reactor - Inductance (μH)50000
5% Enclosed Reactor - Weight (lb)9
5% Enclosed Reactor - Reactor Part NumberURX000215
iQpump1000 - DC Reactors [iQpump1000 - DC Reactors] (7)
Nominal HP1
Rated DC Current (A)2
5% Enclosed Reactor - Inductance (μH)50000
5% Enclosed Reactor - Weight (lb)9
5% Enclosed Reactor - Reactor Part NumberURX000215
iQpump1000 - DC Reactors [iQpump1000 - DC Reactors] (8)
Nominal HP1.5
Rated DC Current (A)4
5% Enclosed Reactor - Inductance (μH)25000
5% Enclosed Reactor - Weight (lb)11
5% Enclosed Reactor - Reactor Part NumberURX000216
iQpump1000 - DC Reactors [iQpump1000 - DC Reactors] (9)
Nominal HP2
Rated DC Current (A)4
5% Enclosed Reactor - Inductance (μH)25000
5% Enclosed Reactor - Weight (lb)11
5% Enclosed Reactor - Reactor Part NumberURX000216
iQpump1000 - Load Reactors
Nominal HP1/2
Nominal 3% Impedance - Reactor Rated Current (A)1
Nominal 3% Impedance - Inductance (μH)36000
Nominal 3% Impedance - Weight (lb)11
Nominal 3% Impedance - Enclosed Part NumberURX000241
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors]
Nominal HP3/4
Nominal 3% Impedance - Reactor Rated Current (A)2
Nominal 3% Impedance - Inductance (μH)20000
Nominal 3% Impedance - Weight (lb)11
Nominal 3% Impedance - Enclosed Part Number05P00620-0016
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors] (2)
Nominal HP1
Nominal 3% Impedance - Reactor Rated Current (A)2
Nominal 3% Impedance - Inductance (μH)20000
Nominal 3% Impedance - Weight (lb)11
Nominal 3% Impedance - Enclosed Part Number05P00620-0016
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors] (3)
Nominal HP1.5
Nominal 3% Impedance - Reactor Rated Current (A)2
Nominal 3% Impedance - Inductance (μH)20000
Nominal 3% Impedance - Weight (lb)11
Nominal 3% Impedance - Enclosed Part Number05P00620-0016
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors] (4)
Nominal HP2
Nominal 3% Impedance - Reactor Rated Current (A)4
Nominal 3% Impedance - Inductance (μH)9000
Nominal 3% Impedance - Weight (lb)12
Nominal 3% Impedance - Enclosed Part Number05P00620-0022
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors] (5)
Nominal HP1/2
Nominal 5% Impedance - Reactor Rated Current (A)1
Nominal 5% Impedance - Inductance (μH)18000
Nominal 5% Impedance - Weight (lb)11
Nominal 5% Impedance - Enclosed Part NumberURX000242
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors] (6)
Nominal HP3/4
Nominal 5% Impedance - Reactor Rated Current (A)2
Nominal 5% Impedance - Inductance (μH)32000
Nominal 5% Impedance - Weight (lb)11
Nominal 5% Impedance - Enclosed Part NumberURX000227
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors] (7)
Nominal HP1
Nominal 5% Impedance - Reactor Rated Current (A)2
Nominal 5% Impedance - Inductance (μH)32000
Nominal 5% Impedance - Weight (lb)11
Nominal 5% Impedance - Enclosed Part NumberURX000227
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors] (8)
Nominal HP1.5
Nominal 5% Impedance - Reactor Rated Current (A)2
Nominal 5% Impedance - Inductance (μH)32000
Nominal 5% Impedance - Weight (lb)11
Nominal 5% Impedance - Enclosed Part NumberURX000227
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors] (9)
Nominal HP2
Nominal 5% Impedance - Reactor Rated Current (A)4
Nominal 5% Impedance - Inductance (μH)12000
Nominal 5% Impedance - Weight (lb)13
Nominal 5% Impedance - Enclosed Part Number05P00620-0023
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors] (10)
Nominal HP1.5
Enclosed AC Reactor - Current (A)6
Enclosed AC Reactor - Inductance (μH)1.500
Enclosed AC Reactor - Weight (lb)1.8
Enclosed AC Reactor - Part NumberURX000411

Documentation & CAD

Files hosted by Yaskawa; links open the official document or download page. 3D CAD requires a free Yaskawa login.

Datasheets & catalogs

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.

Specifications compiled from official Yaskawa product documentation. Always confirm against the datasheet for your exact unit and revision.