IAC

Yaskawa GA50U2008

GA500 - 3 Percent Dynamic Braking Resistors

3% Duty cycle resistors are rated for a 3% duty cycle at 100 second intervals.

Lifecycle & replacement

Lifecycle status not published

Yaskawa's published discontinuation lists (checked 2026-09-01) do not assign a lifecycle status to this part number.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Checked against: Yaskawa America Support By Product - Inverter Drives; Yaskawa America Support By Product - Servo Amplifiers; Yaskawa America Support By Product - Servomotors; Yaskawa America Support By Product - Machine Controllers; Yaskawa America Support By Product - PLC Controllers; Yaskawa America Support By Product - Spindle Drives; Yaskawa America Support By Product - Spindle Motors; Yaskawa product page carrying the verbatim definition of Legacy.

Technical specifications

GA500 - 3 Percent Dynamic Braking Resistors
Normal Duty (HP)2
Heavy Duty (HP)1.5
Quantity1
ohm (each)100
Watts (each)150
Resistor Part NumberR7504
240V, 3-Phase Input, 3% AC Input Reactors
Nominal HP1.5
Catalog Code - Normal DutyGA50U2006
Part Number - Open TypeURX000299
Part Number - Enclosed TypeURX000410
240V, 3-Phase Input, 3% AC Input Reactors [GA500 - AC Input Reactors]
Nominal HP2
Catalog Code - Heavy DutyGA50U2010
Part Number - Open TypeURX000303
Part Number - Enclosed TypeURX000411
240V, 3-Phase Input, 5% AC Input Reactors
Nominal HP1.5
Catalog Code - Normal DutyGA50U2006
Part Number - Open TypeURX000300
Part Number - Enclosed TypeURX000503
240V, 3-Phase Input, 5% AC Input Reactors [GA500 - AC Input Reactors]
Nominal HP2
Catalog Code - Heavy DutyGA50U2010
Part Number - Open TypeURX000304
Part Number - Enclosed TypeURX000504
240V, 3-Phase Input, 3% AC Output Reactors
Nominal HP1.5
Catalog Code - Normal DutyGA50U2006
Part Number - Open Type05P00620-0024
Part Number - Enclosed Type05P00620-0027
240V, 3-Phase Input, 3% AC Output Reactors [GA500 - AC Output Reactors]
Nominal HP2
Catalog Code - Heavy DutyGA50U2010
Part Number - Open Type05P00620-0024
Part Number - Enclosed Type05P00620-0027
240V, 3-Phase Input - 3% Bus Reactors
Nominal HP1.5
Catalog Code - Normal DutyGA50U2006
Part Number - Open Type05P00620-0111
Part Number - Enclosed TypeURX000208
240V, 3-Phase Input - 3% Bus Reactors [GA500 - DC Reactors]
Nominal HP2
Catalog Code - Heavy DutyGA50U2010
Part Number - Open Type05P00620-0110
Part Number - Enclosed TypeURX000257
240V, 3-Phase Input - 5% Bus Reactors
Nominal HP1.5
Catalog Code - Normal DutyGA50U2006
Part Number - Open Type05P00620-0111
Part Number - Enclosed TypeURX000208
240V, 3-Phase Input - 5% Bus Reactors [GA500 - DC Reactors]
Nominal HP2
Catalog Code - Heavy DutyGA50U2010
Part Number - Open Type05P00620-0111
Part Number - Enclosed TypeURX000208

Documentation & CAD

Files hosted by Yaskawa; links open the official document or download page. 3D CAD requires a free Yaskawa login.

Certificates

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.

Specifications compiled from official Yaskawa product documentation. Always confirm against the datasheet for your exact unit and revision.