IAC

Yaskawa GA80U4060

GA800 - 10 Percent Dynamic Braking

Dynamic Braking Resistor, 10% Duty Cycle - are rated for 10% duty cycle over a 100 second interval. The resistors will achieve a minimum 150% peak braking power for heavy duty horsepower ratings and a minimum of 100% peak braking power for normal duty horsepower ratings. These resistors are designed for separate panel mounting.

Lifecycle & replacement

Lifecycle status not published

Yaskawa's published discontinuation lists (checked 2026-09-01) do not assign a lifecycle status to this part number.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Checked against: Yaskawa America Support By Product - Inverter Drives; Yaskawa America Support By Product - Servo Amplifiers; Yaskawa America Support By Product - Servomotors; Yaskawa America Support By Product - Machine Controllers; Yaskawa America Support By Product - PLC Controllers; Yaskawa America Support By Product - Spindle Drives; Yaskawa America Support By Product - Spindle Motors; Yaskawa product page carrying the verbatim definition of Legacy.

Technical specifications

GA800 10 Percent Dynamic Braking Options
Normal Duty HP40
Heavy Duty HP30
10% Dynamic Braking Option (Max 10 Second on-time) - Transistor Module - QuantityBuilt-in
10% Dynamic Braking Option (Max 10 Second on-time) - Resistor - Quantity1
10% Dynamic Braking Option (Max 10 Second on-time) - Resistor Specifications - Resistance18.5
10% Dynamic Braking Option (Max 10 Second on-time) - Resistor Specifications - Watts2984
10% Dynamic Braking Option (Max 10 Second on-time) - Resistor Specifications - EnclosureGCE8
10% Dynamic Braking Option (Max 10 Second on-time) - Transistor Module - Part NumberBuilt-in
10% Dynamic Braking Option (Max 10 Second on-time) - Resistor - Part NumberURS000377
480V, 3% AC Input Reactors
Nominal HP30
Part Number - Open TypeURX000327
Part Number - Enclosed TypeURX000425
480V, 3% AC Input Reactors [GA800 - AC Input Reactors]
Nominal HP40
Catalog Code - Heavy DutyGA80U4075...
Part Number - Open TypeURX000330
Part Number - Enclosed TypeURX000553
480V, 5% AC Input Reactors
Nominal HP30
Part Number - Open TypeNot Required
Part Number - Enclosed TypeNot Required
480V, 5% AC Input Reactors [GA800 - AC Input Reactors]
Nominal HP40
Catalog Code - Heavy DutyGA80U4075...
Part Number - Open TypeNot Required
Part Number - Enclosed TypeNot Required
460V, 3% AC Output Reactors
Nominal HP30
Catalog Code - Normal DutyGA80U4044...
Part Number - Open Type05P00620-0049
Part Number - Enclosed Type05P00620-0051
460V, 3% AC Output Reactors [GA800 - AC Output Reactors]
Nominal HP40
Catalog Code - Heavy DutyGA80U4075...
Part Number - Open Type05P00620-0142
Part Number - Enclosed Type05P00620-0055
GA800 R1000 Options
Motor Power - HP30
Current Suppression Reactor05P00620-0049
Power Coordination Reactor05P00620-0049
Fuses (Qty: 3)FU-000783
Fuse Holder - Part #FU-002082
Fuse Holder - Qty3
Catalog Code - Normal DutyGA80U4044...
R1000 Part Number CIMR-RU 1 24A0020FAA
GA800 R1000 Options [GA800 - R1000 Options]
Motor Power - HP40
Current Suppression Reactor05P00620-0142
Power Coordination Reactor05P00620-0142
Fuses (Qty: 3)UFU000480
Fuse Holder - Part #FU-002082
Fuse Holder - Qty3
Catalog Code - Heavy DutyGA80U4075...
R1000 Part Number CIMR-RU 1 24A0028FAA

Documentation & CAD

Files hosted by Yaskawa; links open the official document or download page. 3D CAD requires a free Yaskawa login.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.

Specifications compiled from official Yaskawa product documentation. Always confirm against the datasheet for your exact unit and revision.