Yaskawa GA80U5125ABM

GA800 Drive

Lifecycle & replacement

Lifecycle status not published

Yaskawa's published discontinuation lists (checked 2026-09-01) do not assign a lifecycle status to this part number.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Checked against: Yaskawa America Support By Product - Inverter Drives; Yaskawa America Support By Product - Servo Amplifiers; Yaskawa America Support By Product - Servomotors; Yaskawa America Support By Product - Machine Controllers; Yaskawa America Support By Product - PLC Controllers; Yaskawa America Support By Product - Spindle Drives; Yaskawa America Support By Product - Spindle Motors; Yaskawa product page carrying the verbatim definition of Legacy.

Technical specifications

600V, 3-Phase, IP20/Protected Chassis
Normal Duty Output - HP125
Normal Duty Output - Amps125
Heavy Duty Output - HP100
Heavy Duty Output - Amps99
Dimensions (in.) 2 - H27.56
Dimensions (in.) 2 - W12.28
Dimensions (in.) 2 - D16.54
Weight (lbs.) 1156.0
Drawing (By Frame #) - 2DFr 9
Drawing (By Frame #) - 3DFr 9
600V, 3-Phase, IP20/UL Type 1 - Fuse Ready
Normal Duty Output - HP125
Normal Duty Output - Amps125
Heavy Duty Output - HP100
Heavy Duty Output - Amps99
Dimensions (in.) 2 - H47.48
Dimensions (in.) 2 - W13.7
Dimensions (in.) 2 - D16.54
Weight (lbs.) 1195.8
Drawing (By Frame #) - 2DFr 9 Fuse Ready 4
Drawing (By Frame #) - 3DFr 9 Fuse Ready 4
Specifications
Overload Capacity150% for 60 sec. (HD), 110% for 60 sec. (ND)
Output Frequency0~590 Hz
Control MethodsOpen and Closed Loop Current Vector; Open and Closed Loop V/f
Motor TypesInduction Surface Permanent Magnet Interior Permanent Magnet Synchronous Reluctance
Protective DesignIP20 (IP20/UL Type 1 kit available) Flange (IP55/UL Type 12 backside)
Protective Design and Ambient Operating TemperatureIP20/Protected Chassis(-10 to +50°C) IP20 with UL Type 1 kit (-10 to +40°C) Flange: front = IP20/Protected Chassis(-10 to +50°C); back = IP55/UL Type12 (-10 to +40°C) All types (additional +10°C with derate)
Global CertificationUL, CSA, CE, RCM, RoHS
Functional SafetySafe Torque Off, SIL3 according to IEC 62061, PLe according to ISO 13849-1 (600V models pending, consult factory)
Standard I/O(8) multi-function digital inputs (24Vdc) (3) multi-function analog inputs (0 +/- 10 VDC, 4-20 mA) (1) multi-function pulse inputs (2) Safe Torque Off inputs (1) fault relay output (form C) (3) multi-function relay outputs (form A) (2) multi-function analog output (0 +/- 10 VDC, 4-20mA) (1) multi-function pulse output
I/O Expansion(3) Analog Inputs -10 to +10V, 13 bit plus sign, 4 to 20mA (16) Digital Inputs (2) Analog Outputs (-10 to +10V, 11 bit magnitude) (8) Digital Outputs (6 transistor, 2 relay)
FeedbackIncremental Absolute (Stegmann, Heidenhain, Resolver)
Network CommunicationStandard: Modbus RTU, RS-485, 115 kbps Optional: EtherNet/IP, DeviceNet, Modbus TCP/IP, PROFINET, PROFIBUS-DP
Speed Control Range1500:1 Closed Loop Vector (IM and PM Motors) 200:1 Open Loop Vector (IM Motors) 100:1 Open Loop Vector (PM Motors)
Speed Control Accuracy≤ 0.02%: Closed Loop Vector; ≤ 0.2%; Open Loop Vector
Speed Response≥ 50 Hz: Closed Loop Vector (Induction Motors) ≥ 250 Hz: Closed Loop Vector (PM Motors) ≥ 20 Hz: Open Loop Vector (Induction Motors) ≥ 40 Hz: Open Loop Vector (PM Motors)
Function Block DiagramsUp to 200 connections, 500us program scan time

Documentation & CAD

Files hosted by Yaskawa; links open the official document or download page. 3D CAD requires a free Yaskawa login.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.

Specifications compiled from official Yaskawa product documentation. Always confirm against the datasheet for your exact unit and revision.