IAC

Yaskawa HV60U4008CVA

HV600 Drive

Lifecycle & replacement

Lifecycle status not published

Yaskawa's published discontinuation lists (checked 2026-09-01) do not assign a lifecycle status to this part number.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Checked against: Yaskawa America Support By Product - Inverter Drives; Yaskawa America Support By Product - Servo Amplifiers; Yaskawa America Support By Product - Servomotors; Yaskawa America Support By Product - Machine Controllers; Yaskawa America Support By Product - PLC Controllers; Yaskawa America Support By Product - Spindle Drives; Yaskawa America Support By Product - Spindle Motors; Yaskawa product page carrying the verbatim definition of Legacy.

Technical specifications

480V, 3-Phase, IP55/UL Type 12
Nominal HP 15
Rated Output Current (Amps)7.6
Dimensions (in.) - H14.1
Dimensions (in.) - W4.9
Dimensions (in.) - D9
Weight (lbs.) 216.5
Drawing (By Frame #) - 2DFr 1
Drawing (By Frame #) - 3DFr 1B
Specifications
Input VoltageThree-phase 200 to 240 VAC, 380 to 480 VAC, +10%/-15%, 50/60 Hz +/-5%
Ambient Operating Temperature-10°C to +50°C (14°F to 122°F), up to 60°C (140°F) with derating
Ambient Storage Temperature-20°C to +70°C (-4°F to 158°F)
Overload Capacity110% for 60 seconds, 140% for 2 seconds, 175% instantaneous
Environmental1,000 meters altitude, up to 4,000 meters with derating Class 3C2 and 3S2 operation for IP20/UL Type 1, Class 3C2 and 3S3 for IP55/UL Type 12 95% humidity, non-condensing IP20/UL Type 1 and IP55/Type 12 plenum rated
EMC and HarmonicsEMC filter built in; complies with IEC 61800-3 restricted distribution for first environment 5% split choke built in both positive and negative DC bus leg as standard
Control MethodsOpen Loop V/f Open Loop Vector for PM Motors Only
Motor TypesInduction Permanent Magnet Synchronous Reluctance
Protective Design TypesIP20/UL Type 1 IP55/UL Type 12 IP20/Protected Chassis IP55/UL Type 12 with Integrated Disconnect Switch
InterfaceLCD keypad with Hand-Off-Auto and Status Ring
Global CertificationsUL, cUL, CE,RoHS 2, WEEE, TUV SUD
Seismic CertificationCBC, IBC, ASCE7, ICC-ES 156 HCAI (Special Seismic Certification Preapproval OSP-0687)
Functional SafetySafe Torque Off, SIL3 according to IEC 62061, PLe according to ISO 1384
Standard I/O(7) programmable multi-function digital inputs (24 VDC) (2) programmable multi-function analog inputs (0 to +10 VDC, 0-20 mA, 4-20 mA) (2) Functional Safety inputs (1) fault relay output (Form C) (3) programmable multi-function relay outputs (Form A) (2) programmable multi-function analog output (0 to +10 VDC, 0-20 mA, 4-20 mA)
24 VDC powerExternal supply input to maintain communications without main power 150 mA output for customer use
Network CommunicationsBuilt-in: BACnet MSTP, Siemens APOGEE FLN P1, Johnson Controls Metasys N2, and Modbus RTU Optional: LonWorks, EtherNet/IP, and Modbus TCP/IP
Software Support ToolsDriveWizard® HVAC DriveWizard Mobile Programming Simulator Energy Savings Predictor Harmonics Estimator DriveWorksEZ

Documentation & CAD

Files hosted by Yaskawa; links open the official document or download page. 3D CAD requires a free Yaskawa login.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.

Specifications compiled from official Yaskawa product documentation. Always confirm against the datasheet for your exact unit and revision.