IAC

Yaskawa SGM7E-10C

SGM7E Direct Drive

Lifecycle & replacement

Lifecycle status not published

Yaskawa's published discontinuation lists (checked 2026-09-01) do not assign a lifecycle status to this part number.

Replacing or upgrading a servo component?

Servo amplifiers, motors, encoders and cables are matched sets. If this part is no longer available in its original form, the manufacturer's newer generation usually will not pair with the rest of the axis, so an upgrade normally covers the drive, motor and cables together. Send us the nameplate details and we will confirm availability of an exact spare or scope a compatible upgrade.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Checked against: Yaskawa America Support By Product - Inverter Drives; Yaskawa America Support By Product - Servo Amplifiers; Yaskawa America Support By Product - Servomotors; Yaskawa America Support By Product - Machine Controllers; Yaskawa America Support By Product - PLC Controllers; Yaskawa America Support By Product - Spindle Drives; Yaskawa America Support By Product - Spindle Motors; Yaskawa product page carrying the verbatim definition of Legacy.

Technical specifications

200V Models 02B - 14C
Rated Output 1 (W42)209
Rated Torque 1, 2 (N• m)10.0
Instantaneous Maximum Torque 1 (N• m)30.0
Stall Torque 1 (N• m)10.1
Rated Current 1 (Arms)2.2
Instantaneous Maximum Current 1 (Arms)7.0
Rated Motor Speed 1 (min -1)200
Maximum Motor Speed 1 (min -1)400
Torque Constant (N• m/Arms)5.05
Motor Moment of Inertia (x10 -4 kg• m)140
Rated Power Rate 1 (kW/s)7.14
Rated Angular Acceleration Rate 1 (rad/s 2)710

Documentation & CAD

Files hosted by Yaskawa; links open the official document or download page. 3D CAD requires a free Yaskawa login.

Datasheets & catalogs

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.

Specifications compiled from official Yaskawa product documentation. Always confirm against the datasheet for your exact unit and revision.