IAC

Yaskawa SGMGH-55DA

SGMGH

Lifecycle & replacement

Legacy

Yaskawa defines this status as: “Legacy products can still be purchased, but are not intended for new applications.”

Successor range/series
  • SGM7GListed under “Retrofit / Upgrade Product”
    IAC note: Joined to matrix row: SGMGH; successor column: Retrofit / Upgrade Product
  • Applies to Yaskawa America (the Americas)
  • Yaskawa support matrix: replacement available, factory repair available, exchange not listed
Servo replacements are a system decision

On a servo axis the amplifier, motor, encoder and cables are a matched set. When a legacy component fails, the manufacturer's current generation usually does not pair with the rest of the original set, so the whole axis typically has to be upgraded together: drive, motor and cables, and often controller parameters or firmware. Replacing only the failed unit is rarely possible. Before ordering, talk to us: we can quote a like-for-like legacy spare or exchange unit to keep the existing installation running, or engineer a matched upgrade path for the axis.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Source: Yaskawa America Support By Product - Servomotors, retrieved 2026-09-01.

Technical specifications

Ratings
System Voltage400V AC
Rated Output 1 - kW (hp)5.5 (7.4)
Rated Torque 1 - N • m35
Rated Torque 1 - lb • in (kg • cm)310 (357)
Instantaneous Peak Torque * - N • m87.6
Instantaneous Peak Torque * - lb • in (kg • cm)775 (894)
Rated Current 1 - A RMS21
Instantaneous Maximum Current 1 - A RMS55
Ratings [SGMAH Sigma II]
System Voltage400V AC
Torque Constant - lb•in/A RMS (N•m/A RMS )15.6 (1.76)
Moment of Inertia - lb•in•s 2 x 10 -378.8
Moment of Inertia - kg•m 2 x 10 -489
Holding Brake (at 20°C) - Capacity - W23.5
Holding Brake (at 20°C) - Torque - N • m72.6
Holding Brake (at 20°C) - Coil Resistance - W24.5
Holding Brake (at 20°C) - Rated Current - A0.98
Holding Brake (at 20°C) - Additional Inertia - lb•in•s 2 x 10 -37.75
Rated Angular Acceleration * - rad/s 23930
Inertia Time Constant - ms1.4
Inductive Time Constant - ms14.4
Ratings [SGMGH]
System Voltage400V AC
Torque Constant15.6 (1.76)
Moment of Inertia89
Holding Brake (at 20°C) - Capacity23.5
Holding Brake (at 20°C) - Torque72.6
Holding Brake (at 20°C) - Coil Resistance24.5
Holding Brake (at 20°C) - Rated Current0.98
Holding Brake (at 20°C) - Additional Inertia7.75
Rated Angular Acceleration *3930
Inertia Time Constant1.4
Inductive Time Constant14.4

Documentation & CAD

Files hosted by Yaskawa; links open the official document or download page. 3D CAD requires a free Yaskawa login.

2D drawings

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.

Specifications compiled from official Yaskawa product documentation. Always confirm against the datasheet for your exact unit and revision.