Yaskawa URX000207
A1000 - DC Reactors
For Nominal HP and Rated Input Voltage, see Models & Ratings.
Lifecycle & replacement
Yaskawa's published discontinuation lists (checked 2026-09-01) do not assign a lifecycle status to this part number.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Checked against: Yaskawa America Support By Product - Inverter Drives; Yaskawa America Support By Product - Servo Amplifiers; Yaskawa America Support By Product - Servomotors; Yaskawa America Support By Product - Machine Controllers; Yaskawa America Support By Product - PLC Controllers; Yaskawa America Support By Product - Spindle Drives; Yaskawa America Support By Product - Spindle Motors; Yaskawa product page carrying the verbatim definition of Legacy.
Technical specifications
200-240, 3-Phase
| Rated DC Current (A) | 4 |
| 3% Enclosed Reactor - Inductance (μH) | 5000 |
| 3% Enclosed Reactor - Weight (lb) | TBD |
| 5% Enclosed Reactor - Inductance (μH) | 4 |
| 5% Enclosed Reactor - Weight (lb) | 9 |
| Drive Model Number - Normal Duty | CIMR-AU2A0004 |
| Drive Model Number - Heavy Duty | CIMR-AU2A0004 |
| 3% Enclosed Reactor - Reactor Part Number | TBD |
200-240, 3-Phase [A1000 - DC Reactors]
| Rated DC Current (A) | 4 |
| 3% Enclosed Reactor - Inductance (μH) | 5000 |
| 3% Enclosed Reactor - Weight (lb) | TBD |
| 5% Enclosed Reactor - Inductance (μH) | 4 |
| 5% Enclosed Reactor - Weight (lb) | 9 |
| Drive Model Number - Normal Duty | CIMR-AU2A0006 |
| Drive Model Number - Heavy Duty | CIMR-AU2A0006 |
| 3% Enclosed Reactor - Reactor Part Number | TBD |
500-600, 3-Phase
| Rated DC Current (A) | 4 |
| 3% Enclosed Reactor - Inductance (μH) | 12000 |
| 3% Enclosed Reactor - Weight (lb) | 9 |
| 5% Enclosed Reactor - Inductance (μH) | 25000 |
| 5% Enclosed Reactor - Weight (lb) | 11 |
| Drive Model Number - Normal Duty | CIMR-AU5A0004 |
| Drive Model Number - Heavy Duty | CIMR-AU5A0006 |
| 5% Enclosed Reactor - Reactor Part Number | URX000216 |
240V, 3-Phase Input - 3% Bus Reactors
| Nominal HP | 1/4 |
| Catalog Code - Normal Duty | GA50U2002 |
| Catalog Code - Heavy Duty | GA50U2002 |
| Part Number - Open Type | URX000041 |
240V, 3-Phase Input - 3% Bus Reactors [GA500 - DC Reactors]
| Nominal HP | 1/2 |
| Catalog Code - Heavy Duty | GA50U2004 |
| Part Number - Open Type | URX000041 |
240V, 3-Phase Input - 3% Bus Reactors [GA500 - DC Reactors] (2)
| Nominal HP | 3/4 |
| Catalog Code - Normal Duty | GA50U2004 |
| Part Number - Open Type | URX000041 |
240V, 3-Phase Input - 5% Bus Reactors
| Nominal HP | 1/2 |
| Catalog Code - Heavy Duty | GA50U2004 |
| Part Number - Open Type | URX000041 |
240V, 3-Phase Input - 5% Bus Reactors [GA500 - DC Reactors]
| Nominal HP | 3/4 |
| Catalog Code - Normal Duty | GA50U2004 |
| Part Number - Open Type | URX000041 |
240V, 3-Phase Input - 3% Bus Reactors [GA501 - DC Reactors]
| Nominal HP | 1/4 |
| Catalog Code - Normal Duty | GA51U2002 |
| Catalog Code - Heavy Duty | GA51U2002 |
| Part Number - Open Type | URX000041 |
240V, 3-Phase Input - 3% Bus Reactors [GA501 - DC Reactors] (2)
| Nominal HP | 1/2 |
| Catalog Code - Heavy Duty | GA51U2004 |
| Part Number - Open Type | URX000041 |
240V, 3-Phase Input - 3% Bus Reactors [GA501 - DC Reactors] (3)
| Nominal HP | 3/4 |
| Catalog Code - Normal Duty | GA51U2004 |
| Part Number - Open Type | URX000041 |
240V, 3-Phase Input - 5% Bus Reactors [GA501 - DC Reactors]
| Nominal HP | 1/2 |
| Catalog Code - Heavy Duty | GA51U2004 |
| Part Number - Open Type | URX000041 |
240V, 3-Phase Input - 5% Bus Reactors [GA501 - DC Reactors] (2)
| Nominal HP | 3/4 |
| Catalog Code - Normal Duty | GA51U2004 |
| Part Number - Open Type | URX000041 |
240V - 3% Bus Reactors
| HP | 0.5 |
| Catalog Code - Normal Duty | GA80U2004... |
| Catalog Code - Heavy Duty | GA80U2004... |
| 3% DC Bus Reactor - Open Type Part Number | URX000036 |
240V - 5% DC Bus Reactors
| HP | 0.75 |
| Catalog Code - Normal Duty | GA80U2004... |
| Catalog Code - Heavy Duty | GA80U2004... |
| 5% DC Bus Reactor - Open Type Part Number | URX000041 |
240V - 5% DC Bus Reactors [GA800 - DC Reactors]
| HP | 1 |
| Catalog Code - Normal Duty | GA80U2006... |
| Catalog Code - Heavy Duty | GA80U2006... |
| 5% DC Bus Reactor - Open Type Part Number | URX000041 |
480V - 3% DC Bus Reactors
| HP | 2 |
| Catalog Code - Normal Duty | GA80U4004... |
| Catalog Code - Heavy Duty | GA80U4005... |
| 3% DC Bus Reactor - Open Type Part Number | URX000041 |
240V, 3-Phase Input - 3% Bus Reactors [HV305 - DC Reactors]
| Nominal HP | 1/4 |
| Catalog Code - Normal Duty | HV35U2002 |
| Catalog Code - Heavy Duty | HV35U2002 |
| Part Number - Open Type | URX000041 |
240V, 3-Phase Input - 3% Bus Reactors [HV305 - DC Reactors] (2)
| Nominal HP | 1/2 |
| Catalog Code - Heavy Duty | HV35U2004 |
| Part Number - Open Type | URX000041 |
240V, 3-Phase Input - 3% Bus Reactors [HV305 - DC Reactors] (3)
| Nominal HP | 3/4 |
| Catalog Code - Normal Duty | HV35U2004 |
| Part Number - Open Type | URX000041 |
240V, 3-Phase Input - 5% Bus Reactors [HV305 - DC Reactors]
| Nominal HP | 1/2 |
| Catalog Code - Heavy Duty | HV35U2004 |
| Part Number - Open Type | URX000041 |
240V, 3-Phase Input - 5% Bus Reactors [HV305 - DC Reactors] (2)
| Nominal HP | 3/4 |
| Catalog Code - Normal Duty | HV35U2004 |
| Part Number - Open Type | URX000041 |
iQpump1000 - DC Reactors
| Nominal HP | 3/4 |
| Rated DC Current (A) | 4 |
| 5% Enclosed Reactor - Inductance (μH) | 12000 |
| 5% Enclosed Reactor - Weight (lb) | 9 |
| Drive Model Number | CIMR-PW2A0004 |
iQpump1000 - DC Reactors [iQpump1000 - DC Reactors]
| Nominal HP | 1 |
| Rated DC Current (A) | 4 |
| 5% Enclosed Reactor - Inductance (μH) | 12000 |
| 5% Enclosed Reactor - Weight (lb) | 9 |
| Drive Model Number | CIMR-PW2A0006 |
iQpump1000 - DC Reactors [iQpump1000 - DC Reactors] (2)
| Nominal HP | 1/2 |
| Enclosed DC Bus Reactor - Current (A) | 4 |
| Enclosed DC Bus Reactor - Inductance (μH) | 12.000 |
| Drive Model Number | CIMR-PW2A0002 |
iQpump1000 - DC Reactors [iQpump1000 - DC Reactors] (3)
| Nominal HP | 1 |
| Enclosed DC Bus Reactor - Current (A) | 4 |
| Enclosed DC Bus Reactor - Inductance (μH) | 12.000 |
| Drive Model Number | CIMR-PW2A0004 |
iQpump1000 - DC Reactors [iQpump1000 - DC Reactors] (4)
| Nominal HP | 3 |
| Rated DC Current (A) | 4 |
| 3% Enclosed Reactor - Inductance (μH) | 12000 |
| 3% Enclosed Reactor - Weight (lb) | 9 |
| Drive Model Number | CIMR-PW5A0004 |
P1000 DC Reactors
| Nominal HP | 3/4 |
| Rated DC Current (A) | 4 |
| 3% Enclosed Reactor - Inductance (μH) | 5000 |
| 3% Enclosed Reactor - Weight (lb) | TBD |
| 5% Enclosed Reactor - Inductance (μH) | 12000 |
| 5% Enclosed Reactor - Weight (lb) | 9 |
| Drive Model Number | CIMR-PU2A0004 |
| 3% Enclosed Reactor - Reactor Part Number | TBD |
P1000 DC Reactors [P1000 DC Reactors]
| Nominal HP | 1 |
| Rated DC Current (A) | 4 |
| 3% Enclosed Reactor - Inductance (μH) | 5000 |
| 3% Enclosed Reactor - Weight (lb) | TBD |
| 5% Enclosed Reactor - Inductance (μH) | 12000 |
| 5% Enclosed Reactor - Weight (lb) | 9 |
| Drive Model Number | CIMR-PU2A0006 |
| 3% Enclosed Reactor - Reactor Part Number | TBD |
P1000 DC Reactors [P1000 DC Reactors] (2)
| Nominal HP | 3 |
| Rated DC Current (A) | 4 |
| 3% Enclosed Reactor - Inductance (μH) | 12000 |
| 3% Enclosed Reactor - Weight (lb) | 9 |
| 5% Enclosed Reactor - Inductance (μH) | 25000 |
| 5% Enclosed Reactor - Weight (lb) | 11 |
| Drive Model Number | CIMR-PU5A0004 |
| 5% Enclosed Reactor - Reactor Part Number | URX000216 |
Documentation & CAD
Files hosted by Yaskawa; links open the official document or download page. 3D CAD requires a free Yaskawa login.
Datasheets & catalogs
Manuals
- Tech Manual
- Arc Flash and PPE Manual Supplement
- Product Transition Guide A1000 to GA800
- Back-up Capacitor Unit for Momentary Power Loss - Option Installation Manual
- GA500 Finless-Type Installation & Primary Operation
- GA500 Finless-Type Installation & Primary Operation (TOEPYAISUP23)
- GA500 Versatile Compact AC Drive Installation & Primary Operation
- GA500 Versatile Compact AC Drive Installation & Primary Operation (EZZ024333)
- GA500 Versatile Compact AC Drive Installation & Primary Operation (TOEPYAISUP12)
- GA500 Versatile Compact AC Drive Technical Reference
- GA500 Versatile Compact AC Drive Technical Reference (TOEPYAISUP23)
- GA500 Versatile Compact AC Drive Technical Reference (TOEPYAISUP12)
- + 73 more on the official site
2D drawings
ECAD / configuration files
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.
Specifications compiled from official Yaskawa product documentation. Always confirm against the datasheet for your exact unit and revision.