Yaskawa URX000243
A1000 - Load Reactors
3% and 5% impedance reactors may be used on the output to reduce the effects of load side transients on the motor.
Lifecycle & replacement
Yaskawa's published discontinuation lists (checked 2026-09-01) do not assign a lifecycle status to this part number.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Checked against: Yaskawa America Support By Product - Inverter Drives; Yaskawa America Support By Product - Servo Amplifiers; Yaskawa America Support By Product - Servomotors; Yaskawa America Support By Product - Machine Controllers; Yaskawa America Support By Product - PLC Controllers; Yaskawa America Support By Product - Spindle Drives; Yaskawa America Support By Product - Spindle Motors; Yaskawa product page carrying the verbatim definition of Legacy.
Technical specifications
200-240V, 3% Line/Load Reactors
| Rated Input Voltage | 200-240V, 3-Phase |
| Nominal HP | 1/2 |
| Nominal 3% Impedance - Reactor Rated Current (A) | 2 |
| Nominal 3% Impedance - Inductance (μH) | 6000 |
| Nominal 3% Impedance - Weight (lb) | 10 |
| Drive Model Number - Normal Duty | CIMR-AU2A0004 |
| Drive Model Number - Heavy Duty | CIMR-AU2A0004 |
240V, 1-Phase Input, 3% AC Output Reactors
| Nominal HP | 1/6 |
| Catalog Code - Normal Duty | GA50UB001 |
| Catalog Code - Heavy Duty | GA50UB001 |
| Part Number - Open Type | URX000080 |
240V, 1-Phase Input, 3% AC Output Reactors [GA500 - AC Output Reactors]
| Nominal HP | 1/4 |
| Catalog Code - Normal Duty | GA50UB002 |
| Catalog Code - Heavy Duty | GA50UB002 |
| Part Number - Open Type | URX000080 |
240V, 3-Phase Input, 3% AC Output Reactors
| Nominal HP | 1/6 |
| Catalog Code - Normal Duty | GA50U2001 |
| Catalog Code - Heavy Duty | GA50U2001 |
| Part Number - Open Type | URX000080 |
240V, 3-Phase Input, 3% AC Output Reactors [GA500 - AC Output Reactors]
| Nominal HP | 1/4 |
| Catalog Code - Normal Duty | GA50U2002 |
| Catalog Code - Heavy Duty | GA50U2002 |
| Part Number - Open Type | URX000080 |
240V, 1-Phase Input, 3% AC Output Reactors [GA501 - AC Output Reactors]
| Nominal HP | 1/6 |
| Catalog Code - Normal Duty | GA51UB001 |
| Catalog Code - Heavy Duty | GA51UB001 |
| Part Number - Open Type | URX000080 |
240V, 1-Phase Input, 3% AC Output Reactors [GA501 - AC Output Reactors] (2)
| Nominal HP | 1/4 |
| Catalog Code - Normal Duty | GA51UB002 |
| Catalog Code - Heavy Duty | GA51UB002 |
| Part Number - Open Type | URX000080 |
240V, 3-Phase Input, 3% AC Output Reactors [GA501 - AC Output Reactors]
| Nominal HP | 1/6 |
| Catalog Code - Normal Duty | GA51U2001 |
| Catalog Code - Heavy Duty | GA51U2001 |
| Part Number - Open Type | URX000080 |
240V, 3-Phase Input, 3% AC Output Reactors [GA501 - AC Output Reactors] (2)
| Nominal HP | 1/4 |
| Catalog Code - Normal Duty | GA51U2002 |
| Catalog Code - Heavy Duty | GA51U2002 |
| Part Number - Open Type | URX000080 |
240V, 1-Phase Input, 3% AC Output Reactors [HV305 - AC Output Reactors]
| Nominal HP | 1/6 |
| Catalog Code - Normal Duty | HV35UB001 |
| Catalog Code - Heavy Duty | HV35UB001 |
| Part Number - Open Type | URX000080 |
240V, 1-Phase Input, 3% AC Output Reactors [HV305 - AC Output Reactors] (2)
| Nominal HP | 1/4 |
| Catalog Code - Normal Duty | HV35UB002 |
| Catalog Code - Heavy Duty | HV35UB002 |
| Part Number - Open Type | URX000080 |
240V, 3-Phase Input, 3% AC Output Reactors [HV305 - AC Output Reactors]
| Nominal HP | 1/6 |
| Catalog Code - Normal Duty | HV35U2001 |
| Catalog Code - Heavy Duty | HV35U2001 |
| Part Number - Open Type | URX000080 |
240V, 3-Phase Input, 3% AC Output Reactors [HV305 - AC Output Reactors] (2)
| Nominal HP | 1/4 |
| Catalog Code - Normal Duty | HV35U2002 |
| Catalog Code - Heavy Duty | HV35U2002 |
| Part Number - Open Type | URX000080 |
iQpump1000 - Load Reactors
| Nominal HP | 1/2 |
| Nominal 3% Impedance - Reactor Rated Current (A) | 2 |
| Nominal 3% Impedance - Inductance (μH) | 6000 |
| Nominal 3% Impedance - Weight (lb) | 10 |
| Drive Model Number | CIMR-PW2A0004 |
P1000 Load Reactors
| Nominal HP | 1/2 |
| Nominal 3% Impedance - Reactor Rated Current (A) | 2 |
| Nominal 3% Impedance - Inductance (μH) | 6000 |
| Nominal 3% Impedance - Weight (lb) | 10 |
| Drive Model Number | CIMR-PU2A0004 |
Documentation & CAD
Files hosted by Yaskawa; links open the official document or download page. 3D CAD requires a free Yaskawa login.
Datasheets & catalogs
Manuals
- Tech Manual
- Arc Flash and PPE Manual Supplement
- Product Transition Guide A1000 to GA800
- Back-up Capacitor Unit for Momentary Power Loss - Option Installation Manual
- GA500 Finless-Type Installation & Primary Operation
- GA500 Finless-Type Installation & Primary Operation (TOEPYAISUP23)
- GA500 Versatile Compact AC Drive Installation & Primary Operation
- GA500 Versatile Compact AC Drive Installation & Primary Operation (EZZ024333)
- GA500 Versatile Compact AC Drive Installation & Primary Operation (TOEPYAISUP12)
- GA500 Versatile Compact AC Drive Technical Reference
- GA500 Versatile Compact AC Drive Technical Reference (TOEPYAISUP23)
- GA500 Versatile Compact AC Drive Technical Reference (TOEPYAISUP12)
- + 37 more on the official site
2D drawings
ECAD / configuration files
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.