IAC

Yaskawa URX000251

A1000 - Load Reactors

1 "Large" P1000 chassis have a built-in DC link reactor equivalent to 3% line reactance. 240 VAC ratings are shown with 3% added AC reactance for 6% total.

Lifecycle & replacement

Lifecycle status not published

Yaskawa's published discontinuation lists (checked 2026-09-01) do not assign a lifecycle status to this part number.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Checked against: Yaskawa America Support By Product - Inverter Drives; Yaskawa America Support By Product - Servo Amplifiers; Yaskawa America Support By Product - Servomotors; Yaskawa America Support By Product - Machine Controllers; Yaskawa America Support By Product - PLC Controllers; Yaskawa America Support By Product - Spindle Drives; Yaskawa America Support By Product - Spindle Motors; Yaskawa product page carrying the verbatim definition of Legacy.

Technical specifications

200-240V, 3% Line/Load Reactors
Rated Input Voltage200-240V, 3-Phase
Nominal HP175
Nominal 3% Impedance - Reactor Rated Current (A)500
Nominal 3% Impedance - Inductance (μH)25
Nominal 3% Impedance - Weight (lb)111
Drive Model Number - Normal DutyCIMR-AU2A0415 1
Drive Model Number - Heavy DutyCIMR-AU2A0415 1
200-240V, 5% Line/Load Reactors
Rated Input Voltage200-240V, 3-Phase
Nominal HP175
Nominal 5% Impedance - Reactor Rated Current (A)500
Nominal 5% Impedance - Inductance (μH)25
Nominal 5% Impedance - Weight (lb)111
Drive Model Number - Normal DutyCIMR-AU2A0415 1
Drive Model Number - Heavy DutyCIMR-AU2A0312 1
380-480V, 3% Line/Load Reactors
Rated Input Voltage380-480V, 3-Phase
Nominal HP350
Nominal 3% Impedance - Reactor Rated Current (A)500
Nominal 3% Impedance - Inductance (μH)25
Nominal 3% Impedance - Weight (lb)120
Drive Model Number - Normal DutyCIMR-AU4A0414 1
Drive Model Number - Heavy DutyCIMR-AU4A0515 1
380-480V, 3% Line/Load Reactors [A1000 - Load Reactors]
Rated Input Voltage380-480V, 3-Phase
Nominal HP400
Nominal 3% Impedance - Reactor Rated Current (A)500
Nominal 3% Impedance - Inductance (μH)25
Nominal 3% Impedance - Weight (lb)120
Drive Model Number - Normal DutyCIMR-AU4A0515 1
Drive Model Number - Heavy DutyCIMR-AU4A0675 1
iQpump1000 - Load Reactors
Nominal HP175
Nominal 3% Impedance - Reactor Rated Current (A)500
Nominal 3% Impedance - Inductance (μH)25
Nominal 3% Impedance - Weight (lb)111
Drive Model NumberCIMR-PW2A0415 1
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors]
Nominal HP175
Nominal 5% Impedance - Reactor Rated Current (A)500
Nominal 5% Impedance - Inductance (μH)25
Nominal 5% Impedance - Weight (lb)111
Drive Model NumberCIMR-PW2A0415 1
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors] (2)
Nominal HP350
Nominal 3% Impedance - Reactor Rated Current (A)500
Nominal 3% Impedance - Inductance (μH)25
Nominal 3% Impedance - Weight (lb)120
Drive Model NumberCIMR-PW4A0414 1
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors] (3)
Nominal HP400
Nominal 3% Impedance - Reactor Rated Current (A)500
Nominal 3% Impedance - Inductance (μH)25
Nominal 3% Impedance - Weight (lb)120
Drive Model NumberCIMR-PW4A0515 1
P1000 Load Reactors
Nominal HP175
Nominal 3% Impedance - Reactor Rated Current (A)500
Nominal 3% Impedance - Inductance (μH)25
Nominal 3% Impedance - Weight (lb)111
Drive Model NumberCIMR-PU2A0415
P1000 Load Reactors [P1000 Load Reactors]
Nominal HP175
Nominal 5% Impedance - Reactor Rated Current (A)500
Nominal 5% Impedance - Inductance (μH)25
Nominal 5% Impedance - Weight (lb)111
Drive Model NumberCIMR-PU2A0415
P1000 Load Reactors [P1000 Load Reactors] (2)
Nominal HP350
Nominal 3% Impedance - Reactor Rated Current (A)500
Nominal 3% Impedance - Inductance (μH)25
Nominal 3% Impedance - Weight (lb)120
Drive Model NumberCIMR-PU4A0414
P1000 Load Reactors [P1000 Load Reactors] (3)
Nominal HP400
Nominal 3% Impedance - Reactor Rated Current (A)500
Nominal 3% Impedance - Inductance (μH)25
Nominal 3% Impedance - Weight (lb)120
Drive Model NumberCIMR-PU4A0515

Documentation & CAD

Files hosted by Yaskawa; links open the official document or download page. 3D CAD requires a free Yaskawa login.

Datasheets & catalogs

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.

Specifications compiled from official Yaskawa product documentation. Always confirm against the datasheet for your exact unit and revision.