Yaskawa URX000259
A1000 - DC Reactors
For Nominal HP and Rated Input Voltage, see Models & Ratings.
Lifecycle & replacement
Yaskawa's published discontinuation lists (checked 2026-09-01) do not assign a lifecycle status to this part number.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Checked against: Yaskawa America Support By Product - Inverter Drives; Yaskawa America Support By Product - Servo Amplifiers; Yaskawa America Support By Product - Servomotors; Yaskawa America Support By Product - Machine Controllers; Yaskawa America Support By Product - PLC Controllers; Yaskawa America Support By Product - Spindle Drives; Yaskawa America Support By Product - Spindle Motors; Yaskawa product page carrying the verbatim definition of Legacy.
Technical specifications
200-240, 3-Phase
| Rated DC Current (A) | 18 |
| 3% Enclosed Reactor - Inductance (μH) | 1375 |
| 3% Enclosed Reactor - Weight (lb) | 11 |
| 5% Enclosed Reactor - Inductance (μH) | 18 |
| 5% Enclosed Reactor - Weight (lb) | 14 |
| Drive Model Number - Normal Duty | CIMR-AU2A0018 |
| Drive Model Number - Heavy Duty | CIMR-AU2A0021 |
| 5% Enclosed Reactor - Reactor Part Number | URX000210 |
240V, 3-Phase Input - 3% Bus Reactors
| Nominal HP | 5 |
| Catalog Code - Normal Duty | GA50U2018 |
| Catalog Code - Heavy Duty | GA50U2021 |
| Part Number - Open Type | 05P00620-0115 |
240V, 3-Phase Input - 3% Bus Reactors [GA501 - DC Reactors]
| Nominal HP | 5 |
| Catalog Code - Heavy Duty | GA51U2021 |
| Part Number - Open Type | 05P00620-0115 |
240V - 3% Bus Reactors
| HP | 4 |
| Catalog Code - Normal Duty | GA80U2012... |
| Catalog Code - Heavy Duty | GA80U2018... |
| 3% DC Bus Reactor - Open Type Part Number | 05P00620-0115 |
240V - 3% Bus Reactors [GA800 - DC Reactors]
| HP | 5 |
| Catalog Code - Normal Duty | GA80U2018... |
| Catalog Code - Heavy Duty | GA80U2021... |
| 3% DC Bus Reactor - Open Type Part Number | 05P00620-0115 |
240V, 3-Phase Input - 3% Bus Reactors [HV305 - DC Reactors]
| Nominal HP | 5 |
| Catalog Code - Normal Duty | HV35U2018 |
| Catalog Code - Heavy Duty | HV35U2021 |
| Part Number - Open Type | 05P00620-0115 |
iQpump1000 - DC Reactors
| Nominal HP | 5 |
| Rated DC Current (A) | 18 |
| 3% Enclosed Reactor - Inductance (μH) | 1375 |
| 3% Enclosed Reactor - Weight (lb) | 11 |
| Drive Model Number | CIMR-PW2A0018 |
iQpump1000 - DC Reactors [iQpump1000 - DC Reactors]
| Nominal HP | 2 |
| Enclosed DC Bus Reactor - Current (A) | 18 |
| Enclosed DC Bus Reactor - Inductance (μH) | 1.375 |
| Drive Model Number | CIMR-PW2A0012 |
iQpump1000 - DC Reactors [iQpump1000 - DC Reactors] (2)
| Nominal HP | 5 |
| Enclosed DC Bus Reactor - Current (A) | 18 |
| Enclosed DC Bus Reactor - Inductance (μH) | 2.750 |
| Drive Model Number | CIMR-PW2A0017 |
P1000 DC Reactors
| Nominal HP | 5 |
| Rated DC Current (A) | 18 |
| 3% Enclosed Reactor - Inductance (μH) | 1375 |
| 3% Enclosed Reactor - Weight (lb) | 11 |
| 5% Enclosed Reactor - Inductance (μH) | 2750 |
| 5% Enclosed Reactor - Weight (lb) | 14 |
| Drive Model Number | CIMR-PU2A0018 |
| 5% Enclosed Reactor - Reactor Part Number | URX000210 |
Documentation & CAD
Files hosted by Yaskawa; links open the official document or download page. 3D CAD requires a free Yaskawa login.
Datasheets & catalogs
Manuals
- Tech Manual
- Arc Flash and PPE Manual Supplement
- Product Transition Guide A1000 to GA800
- Back-up Capacitor Unit for Momentary Power Loss - Option Installation Manual
- GA500 Finless-Type Installation & Primary Operation
- GA500 Finless-Type Installation & Primary Operation (TOEPYAISUP23)
- GA500 Versatile Compact AC Drive Installation & Primary Operation
- GA500 Versatile Compact AC Drive Installation & Primary Operation (EZZ024333)
- GA500 Versatile Compact AC Drive Installation & Primary Operation (TOEPYAISUP12)
- GA500 Versatile Compact AC Drive Technical Reference
- GA500 Versatile Compact AC Drive Technical Reference (TOEPYAISUP23)
- GA500 Versatile Compact AC Drive Technical Reference (TOEPYAISUP12)
- + 73 more on the official site
2D drawings
ECAD / configuration files
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.
Specifications compiled from official Yaskawa product documentation. Always confirm against the datasheet for your exact unit and revision.