IAC

Yaskawa URX000409

GA500 - AC Input Reactors

3% and 5% impedance reactors may be used on the input to reduce the effects of line side transients on the drive.

Lifecycle & replacement

Lifecycle status not published

Yaskawa's published discontinuation lists (checked 2026-09-01) do not assign a lifecycle status to this part number.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Checked against: Yaskawa America Support By Product - Inverter Drives; Yaskawa America Support By Product - Servo Amplifiers; Yaskawa America Support By Product - Servomotors; Yaskawa America Support By Product - Machine Controllers; Yaskawa America Support By Product - PLC Controllers; Yaskawa America Support By Product - Spindle Drives; Yaskawa America Support By Product - Spindle Motors; Yaskawa product page carrying the verbatim definition of Legacy.

Technical specifications

240V, 3-Phase Input, 3% AC Input Reactors
Nominal HP1/2
Catalog Code - Heavy DutyGA50U2004
Part Number - Open TypeURX000295
240V, 3-Phase Input, 3% AC Input Reactors [GA500 - AC Input Reactors]
Nominal HP3/4
Catalog Code - Normal DutyGA50U2004
Part Number - Open TypeURX000295
240V, 3-Phase Input, 3% AC Input Reactors [GA501 - AC Input Reactors]
Nominal HP1/2
Catalog Code - Heavy DutyGA51U2004
Part Number - Open TypeURX000295
240V, 3-Phase Input, 3% AC Input Reactors [GA501 - AC Input Reactors] (2)
Nominal HP3/4
Catalog Code - Normal DutyGA51U2004
Part Number - Open TypeURX000295
240V, 3% AC Input Reactors
Nominal HP0.75
Catalog Code - Normal DutyGA80U2004...
Catalog Code - Heavy DutyGA80U2006...
Part Number - Open TypeURX000295
240V, 3% AC Input Reactors [GA800 - AC Input Reactors]
Nominal HP1
Catalog Code - Normal DutyGA80U2004...
Catalog Code - Heavy DutyGA80U2006...
Part Number - Open TypeURX000295
240V, 3-Phase Input, 3% AC Input Reactors [HV305 - AC Input Reactors]
Nominal HP1/2
Catalog Code - Heavy DutyHV35U2004
Part Number - Open TypeURX000295
240V, 3-Phase Input, 3% AC Input Reactors [HV305 - AC Input Reactors] (2)
Nominal HP3/4
Catalog Code - Normal DutyHV35U2004
Part Number - Open TypeURX000295
iQpump1000 - Load Reactors
Nominal HP1/2
Enclosed AC Reactor - Current (A)3.4
Enclosed AC Reactor - Inductance (μH)3.200
Enclosed AC Reactor - Weight (lb)1.6
Drive Model NumberCIMR-PW4A0002

Documentation & CAD

Files hosted by Yaskawa; links open the official document or download page. 3D CAD requires a free Yaskawa login.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.

Specifications compiled from official Yaskawa product documentation. Always confirm against the datasheet for your exact unit and revision.