Yaskawa URX000428
FP605 - AC Input Reactors
3% and 5% impedance reactors may be used on the input to reduce the effects of line side transients on the drive.
Lifecycle & replacement
Yaskawa's published discontinuation lists (checked 2026-09-01) do not assign a lifecycle status to this part number.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Checked against: Yaskawa America Support By Product - Inverter Drives; Yaskawa America Support By Product - Servo Amplifiers; Yaskawa America Support By Product - Servomotors; Yaskawa America Support By Product - Machine Controllers; Yaskawa America Support By Product - PLC Controllers; Yaskawa America Support By Product - Spindle Drives; Yaskawa America Support By Product - Spindle Motors; Yaskawa product page carrying the verbatim definition of Legacy.
Technical specifications
240V, 3-Phase Input, 1.5% AC Input Reactors
| Nominal HP | 15 |
| Catalog Code | FP65U2046 |
| Part Number - Open Type | URX000338 |
240V, 3-Phase Input, 3% AC Input Reactors
| Nominal HP | 30 |
| Catalog Code | FP65U2088 |
| Part Number - Open Type | URX000338 |
240V, 3% AC Input Reactors
| Nominal HP | 30 |
| Catalog Code - Normal Duty | GA80U2082... |
| Part Number - Open Type | URX000338 |
240V, 3% AC Input Reactors [GA800 - AC Input Reactors]
| Nominal HP | 30 |
| Catalog Code - Heavy Duty | GA80U2110… |
| Part Number - Open Type | URX000338 |
240V, 3% AC Input Reactors [GA800 - AC Input Reactors] (2)
| Nominal HP | 40 |
| Catalog Code - Normal Duty | GA80U2110... |
| Catalog Code - Heavy Duty | GA80U2138... |
| Part Number - Open Type | URX000338 |
iQpump1000 - Load Reactors
| Nominal HP | 25 |
| Enclosed AC Reactor - Current (A) | 104 |
| Enclosed AC Reactor - Inductance (μH) | 0.120 |
| Enclosed AC Reactor - Weight (lb) | 22 |
| Drive Model Number | CIMR-PW5A0077 |
iQpump1000 - Load Reactors [iQpump1000 - Load Reactors]
| Nominal HP | 25 |
| Enclosed AC Reactor - Current (A) | 104 |
| Enclosed AC Reactor - Inductance (μH) | 0.120 |
| Enclosed AC Reactor - Weight (lb) | 22 |
| Drive Model Number | CIMR-PW5A0099 |
240V, 3-Phase Input, 1.5% AC Input Reactors [iQpump605 - AC Input Reactors]
| Nominal HP | 15 |
| Catalog Code | WM65W2046 |
| Part Number - Open Type | URX000338 |
240V, 3-Phase Input, 3% AC Input Reactors [iQpump605 - AC Input Reactors]
| Nominal HP | 30 |
| Catalog Code | WM65W2088 |
| Part Number - Open Type | URX000338 |
Documentation & CAD
Files hosted by Yaskawa; links open the official document or download page. 3D CAD requires a free Yaskawa login.
Datasheets & catalogs
Manuals
- FP605 Installation & Primary Operation
- FP605 Installation & Primary Operation (TOEPYAISUP22)
- FP605 Installation & Primary Operation (EZZ024329)
- FP605 Drive AC Drive for Industrial Fan and Pump Applications Technical Reference
- FP605 Drive AC Drive for Industrial Fan and Pump Applications Technical Reference (TOEPYAISUP22)
- FP605 Drive AC Drive for Industrial Fan and Pump Applications Technical Reference (EZZ024352)
- FP605 with Main Switch Installation & Primary Operation
- FP605 Programming Manual
- FP605 Maintenance & Troubleshooting Manual
- FP605 Drive IP55/UL Type 12 Heatsink External Mounting Installation Manual
- FP605 Quick Setup Procedure for IP55/UL Type 12 External Heatsink Models FP65U2211 to 2396 and 4180 to 4720
- FP605 Quick Setup Procedure for IP55/UL Type 12 w/Main Switch Models FP65U2011 to 2114 and 4005 to 4096
- + 80 more on the official site
2D drawings
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.
Specifications compiled from official Yaskawa product documentation. Always confirm against the datasheet for your exact unit and revision.