IAC

Yaskawa USR000022

G7 Braking Options

Dynamic Braking Resistor, 10% Duty Cycle - are rated for 10% duty cycle over a 100 second interval. These resistors are designed for separate panel mounting. Braking transistors are built-in on all GA500 models.

Lifecycle & replacement

Lifecycle status not published

Yaskawa's published discontinuation lists (checked 2026-09-01) do not assign a lifecycle status to this part number.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Checked against: Yaskawa America Support By Product - Inverter Drives; Yaskawa America Support By Product - Servo Amplifiers; Yaskawa America Support By Product - Servomotors; Yaskawa America Support By Product - Machine Controllers; Yaskawa America Support By Product - PLC Controllers; Yaskawa America Support By Product - Spindle Drives; Yaskawa America Support By Product - Spindle Motors; Yaskawa product page carrying the verbatim definition of Legacy.

Technical specifications

G7 Dynamic Braking Resistor 10 Percent
Nominal HP 13/4
Transistor Module(s) - QtyIncluded
Resistor(s) - Qty1
Resistor(s) - Configuration 2Single (4)
Drive Model Number CIMR-G7U20P71
Transistor Module(s) - Part Number CDBR-Included
G7 Dynamic Braking Resistor 10 Percent [G7 Braking Options]
Nominal HP 11
Transistor Module(s) - QtyIncluded
Resistor(s) - Qty1
Resistor(s) - Configuration 2Single (4)
Drive Model Number CIMR-G7U20P71
Transistor Module(s) - Part Number CDBR-Included
G7 Dynamic Braking Resistor 10 Percent [G7 Braking Options] (2)
Nominal HP 13/4
Transistor Module(s) - QtyIncluded
Resistor(s) - Qty1
Resistor(s) - Configuration 2Single (4)
Drive Model Number CIMR-G7U20P41
Transistor Module(s) - Part Number CDBR-Included
GA500 - 10 Percent Dynamic Braking
Normal Duty HP3/4
Heavy Duty HP1/2
10% Dynamic Braking Option (Max 10 Second on-time) - Resistor - Quantity1
10% Dynamic Braking Option (Max 10 Second on-time) - Resistor Specifications - Resistance200
10% Dynamic Braking Option (Max 10 Second on-time) - Resistor Specifications - Watts250
10% Dynamic Braking Option (Max 10 Second on-time) - Resistor Specifications - EnclosureGCE1
Catalog CodeGA50UB004...
GA500 - 10 Percent Dynamic Braking [GA500 - 10 Percent Dynamic Braking]
Normal Duty HP3/4
Heavy Duty HP1/2
10% Dynamic Braking Option (Max 10 Second on-time) - Resistor - Quantity1
10% Dynamic Braking Option (Max 10 Second on-time) - Resistor Specifications - Resistance200
10% Dynamic Braking Option (Max 10 Second on-time) - Resistor Specifications - Watts250
10% Dynamic Braking Option (Max 10 Second on-time) - Resistor Specifications - EnclosureGCE1
Catalog CodeGA50U2004...
GA501 - 10 Percent Dynamic Braking
Normal Duty HP3/4
Heavy Duty HP1/2
10% Dynamic Braking Option (Max 10 Second on-time) - Resistor - Quantity1
10% Dynamic Braking Option (Max 10 Second on-time) - Resistor Specifications - Resistance200
10% Dynamic Braking Option (Max 10 Second on-time) - Resistor Specifications - Watts250
10% Dynamic Braking Option (Max 10 Second on-time) - Resistor Specifications - EnclosureGCE1
Catalog CodeGA51UB004...
GA501 - 10 Percent Dynamic Braking [GA501 - 10 Percent Dynamic Braking]
Normal Duty HP3/4
Heavy Duty HP1/2
10% Dynamic Braking Option (Max 10 Second on-time) - Resistor - Quantity1
10% Dynamic Braking Option (Max 10 Second on-time) - Resistor Specifications - Resistance200
10% Dynamic Braking Option (Max 10 Second on-time) - Resistor Specifications - Watts250
10% Dynamic Braking Option (Max 10 Second on-time) - Resistor Specifications - EnclosureGCE1
Catalog CodeGA51U2004...
Rated Input Voltage: 200-240V Single Phase
10% DB Resistor - Quantity Required1
10% DB Resistor - Resistance (Ohms) (Each)200
10% DB Resistor - Power (Watts) (Each)250
10% DB Resistor - Approximate Peak Braking Torque (%) - ND120
10% DB Resistor - Approximate Peak Braking Torque (%) - HD150
10% DB Resistor - Dimensions (Inches) - Length12
10% DB Resistor - Dimensions (Inches) - Width5
10% DB Resistor - Dimensions (Inches) - Height5
Drive Model NumberCIMR-JUBA0003BAA
Rated Input Voltage: 200-240V Three Phase
10% DB Resistor - Quantity Required1
10% DB Resistor - Resistance (Ohms) (Each)200
10% DB Resistor - Power (Watts) (Each)250
10% DB Resistor - Approximate Peak Braking Torque (%) - ND120
10% DB Resistor - Approximate Peak Braking Torque (%) - HD150
10% DB Resistor - Dimensions (Inches) - Length12
10% DB Resistor - Dimensions (Inches) - Width5
10% DB Resistor - Dimensions (Inches) - Height5
Drive Model NumberCIMR-JU2A0004BAA
V1000 Dynamic Braking Resistor 10 Percent
10% DB Resistor - Quantity Required1
10% DB Resistor - Resistance (Ohms) (Each)200
10% DB Resistor - Power (Watts) (Each)250
10% DB Resistor - Approximate Peak Braking Torque (%) - ND120
10% DB Resistor - Approximate Peak Braking Torque (%) - HD150
10% DB Resistor - Dimensions (Inches) - Length12
10% DB Resistor - Dimensions (Inches) - Width5
10% DB Resistor - Dimensions (Inches) - Height5
Drive Model NumberCIMR-VUBA0003FAA
V1000 Dynamic Braking Resistor 10 Percent [V1000 - Dynamic Braking Resistor 10 Percent]
10% DB Resistor - Quantity Required1
10% DB Resistor - Resistance (Ohms) (Each)200
10% DB Resistor - Power (Watts) (Each)250
10% DB Resistor - Approximate Peak Braking Torque (%) - ND120
10% DB Resistor - Approximate Peak Braking Torque (%) - HD150
10% DB Resistor - Dimensions (Inches) - Length12
10% DB Resistor - Dimensions (Inches) - Width5
10% DB Resistor - Dimensions (Inches) - Height5
Drive Model NumberCIMR-VU2A0004FAA

Documentation & CAD

Files hosted by Yaskawa; links open the official document or download page. 3D CAD requires a free Yaskawa login.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs Yaskawa parts — new, refurbished, or exchange units with warranty.

Specifications compiled from official Yaskawa product documentation. Always confirm against the datasheet for your exact unit and revision.