IAC

B&R X20AI2438

2 analog current measurement inputs Integrated HART protocol Supports HART variables Electrically isolated analog channels Electrically isolated sensor supplies 16-bit digital converter resolution NetTime timestamp: Moment of measurement, HART image The module is equipped with 2 current measurement inputs with 16-bit digital converter resolution. It supports the HART communication standard for data transfer, parameter configuration and diagnostics. Each current measurement input has its own sensor supply. The two channels with their respective sensor supplies are electrically isolated from each other. The user can select between the two measurement ranges 4 to 20 mA and 0 to 25 mA.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
I/O module2 analog inputs 4 to 20 mA or 0 to 25 mA
General information
Diagnostics / Module run/errorYes, using LED status indicator and software
Diagnostics / InputsYes, using LED status indicator and software
Diagnostics / Sensor power supplyYes, using LED status indicator and software
Diagnostics / HART linkYes, using LED status indicator and software
Diagnostics / HART errorYes, using LED status indicator and software
Power consumption / Bus0.05 W
Power consumption / Internal I/O1.15 W
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X
Certifications / ULcULus E115267 Industrial control equipment
Certifications / HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
Certifications / DNVTemperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)
Certifications / CCSYes
Certifications / LRENV1
Certifications / KRYes
Certifications / ABSYes
Certifications / BVEC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck
Certifications / KCYes
B&R ID code0xB3A9
Status indicatorsI/O function per channel, operating state, module status, sensor power supply per channel, HART
Additional power dissipation caused by actuators (resistive) [W]-
Analog inputs
Data output rate / With HART4.7 to 10 samples per second, configurable using software
Data output rate / Analog4.7 to 100 samples per second, configurable using software
Output format / 4 to 20 mAINT 0x0000 - 0x7FFF / 1 LSB = 0x0001 = 488.281 nA
Output format / 0 to 25 mAINT 0x0000 - 0x7FFF / 1 LSB = 0x0001 = 762.939 nA
Output format / 0 to 25000 µAINT 0x0000 - 0x61A8 / 1 LSB = 0x0001 = 1000 nA
Max. error / Gain / 0 to 25 mA<0.046%
Max. error / Gain / 4 to 20 mA<0.046%
Max. error / Offset / 0 to 25 mA<0.004%
Max. error / Offset / 4 to 20 mA<0.013%
Common-mode rejection / DC80 dB
Common-mode rejection / 50 HzDepends on the sampling rate: e.g. >130 dB for 50 samples per second
Input filter / HardwareFirst-order low-pass filter / cutoff frequency 100 Hz
Input filter / SoftwareSinc⁴ filter
Max. gain drift / 0 to 25 mA0.003 %/°C
Max. gain drift / 4 to 20 mA0.003 %/°C
Max. offset drift / 0 to 25 mA0.0002 %/°C
Max. offset drift / 4 to 20 mA0.0007 %/°C
Test voltage / Channel - Channel1000 VAC
Test voltage / Channel - Bus1000 VAC
Test voltage / Channel - Ground1000 VAC
Input4 to 20 mA or 0 to 25 mA configurable using software
Input typeDifferential input
Digital converter resolution16-bit
Output formatINT
LoadI_IN ≥ 0.1 mA: R < 8000 Ω I_IN ≥ 1 mA: R < 1100 Ω I_IN ≥ 4 mA: R < 510 Ω
Input protectionUp to 30 VDC, reverse polarity protection (max. 0.1 A)
Open-circuit detectionYes, using software
Permissible input signal0 to 25 mA
Output of digital value during overloadConfigurable
Conversion procedureSigma-delta
Common-mode range0 to 7 V
Nonlinearity<0.003%
Sensor power supply
Max. voltage ripple / Up to 100 kHz≤2.2 mV
Max. voltage ripple / Up to 1 MHz≤22 mV
Max. voltage ripple / Higher≤100 mV
Short-circuit current / Typical<50 mA
Short-circuit current / Maximum60 mA
Power consumption0.75 W per channel
Nominal voltage25 V ±2%
Nominal output currentMax. 30 mA
Short-circuit proofYes, continuous
Behavior on short circuitCurrent limiting
HART
Multi-drop operation / PossibleYes
Multi-drop operation / Stations5 nodes (when using HART slaves with a nominal current of 4 mA) Up to 15 (taking into account the maximum permissible input signal of 25 mA)
Transmission amplitude / Minimum400 mVpp
Transmission amplitude / Typical500 mVpp
Transmission amplitude / Maximum600 mVpp
Receiving amplitude / Minimum120 mVpp
Receiving amplitude / Maximum800 mVpp
Transfer rate1200 bit/s
Operating frequencies1200 Hz / 2200 Hz
Burst operation possibleYes
Electrical properties
Electrical isolationChannel isolated from channel and bus Sensor power supply isolated from sensor power supply Sensor power supply not isolated from channel
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation-25 to 60°C
Temperature / Operation / Vertical mounting orientation-25 to 50°C
Temperature / Derating-
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Relative humidity / Operation5 to 95%, non-condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
NoteOrder 1x terminal block X20TB12 separately. Order 1x bus module X20BM11 separately.
Pitch12.5⁺⁰.² mm

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.