B&R X20AI8039
±10 V 0 to 20 mA / 4 to 20 mA 2- or 3-wire Pt100/Pt1000 resistance temperature measurement ICTD measurement This module is equipped with 8 configurable inputs. The measurement type of each input can be set individually.
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Short description
| I/O module | 8 configurable inputs: ±10 V, 0 to 20 mA, 4 to 20 mA, Pt100 / Pt1000 resistance temperature measurement or ICTD measurement |
| Interfaces | 1x X2X Link |
General information
| Diagnostics / Module run/error | Yes, using LED status indicator and software |
| Diagnostics / Inputs | Yes, using LED status indicator and software |
| Power consumption / Bus | 0.6 W |
| Power consumption / Internal I/O | 1.3 W |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| Certifications / UL | cULus E115267 Industrial control equipment |
| B&R ID code | 0x32A4 |
| Status indicators | I/O function per channel, operating state, module status |
| Additional power dissipation caused by actuators (resistive) [W] | - |
Analog inputs
| Digital converter resolution / Voltage | ±15-bit |
| Digital converter resolution / Current | 15-bit |
| Output format / Data type | INT |
| Output format / Voltage | INT 0x8001 - 0x7FFF / 1 LSB = 0x0001 = 305.176 µV |
| Output format / Current | INT 0x0000 - 0x7FFF / 1 LSB = 0x0001 = 610.352 nA |
| Input impedance in signal range / Voltage | Typ. 20 GΩ |
| Input impedance in signal range / Current | - |
| Load / Voltage | - |
| Load / Current | <350 Ω |
| Permissible input signal / Voltage | Max. ±32 V |
| Permissible input signal / Current | Max. ±50 mA |
| Output of digital value during overload / Undershoot / Voltage | 0x8001 |
| Output of digital value during overload / Undershoot / Current | 0x0000 |
| Output of digital value during overload / Overshoot / Voltage | 0x7FFF |
| Output of digital value during overload / Overshoot / Current | 0x7FFF |
| Max. error / Voltage / Gain | ±0.05% |
| Max. error / Voltage / Offset | ±0.005% |
| Max. error / Current / Gain | ±0.05% |
| Max. error / Current / Offset | ±0.01% |
| Max. gain drift / Voltage | ±0.005%/°C |
| Max. gain drift / Current | ±0.005%/°C |
| Max. offset drift / Voltage | ±0.0001%/°C |
| Max. offset drift / Current | ±0.0002%/°C |
| Common-mode rejection / DC | -96 dB |
| Common-mode rejection / 50 Hz | -96 dB |
| Nonlinearity / Voltage | <0.005% |
| Nonlinearity / Current | <0.005% |
| Input filter / Hardware | Third-order low-pass filter / Cutoff frequency 10 kHz |
| Input filter / Software | Configurable: Sinc 1 to 4 filter or FIR |
| Input | ±10 V, 0 to 20 mA, 4 to 20 mA |
| Input type | Differential input |
| Conversion time | Configurable for each channel |
| Input protection | Protection against wiring with supply voltage |
| Conversion procedure | Sigma-delta |
| Common-mode range | ±12 V |
| Crosstalk between channels | <-88 dB |
| Insulation voltage between channel and bus | 1210 VDC |
Resistance measurement temperature inputs
| Sensor / Sensor type | Configurable per channel |
| Sensor / Pt100 | -200 to 850°C |
| Sensor / Pt1000 | -200 to 850°C |
| Max. error at 25°C / Gain | Pt100 and 600 Ω: ±0.15% / Pt1000 and 4800 Ω: ±0.15% |
| Max. error at 25°C / Offset | Pt100 and 600 Ω: ±0.04% / Pt1000 and 4800 Ω: ±0.015% |
| Temperature sensor resolution / Pt100 | 1 LSB = 0.1 or 0.01°C |
| Temperature sensor resolution / Pt1000 | 1 LSB = 0.1 or 0.01°C |
| Input filter / Hardware | Third-order low-pass filter / Cutoff frequency 10 kHz |
| Input filter / Software | Configurable: Sinc 1 to 4 filter or FIR |
| Common-mode rejection / 50 Hz | >96 dB |
| Common-mode rejection / DC | >96 dB |
| Temperature sensor normalization / Pt100 | INT: -200.0 to 850.0°C DINT: -200.00 to 850.00°C |
| Temperature sensor normalization / Pt1000 | INT: -200.0 to 850.0°C DINT: -200.00 to 850.00°C |
| Temperature measurement monitoring / Range undershoot | 0x8001 |
| Temperature measurement monitoring / Range overshoot | 0x7FFF |
| Temperature measurement monitoring / Open circuit | 0x7FFF |
| Temperature measurement monitoring / General fault | 0x8000 |
| Temperature measurement monitoring / Open inputs | 0x7FFF |
| Resistance measurement monitoring / Range overshoot | 0xFFFF |
| Resistance measurement monitoring / Open circuit | 0xFFFF |
| Resistance measurement monitoring / General fault | 0xFFFF |
| Resistance measurement monitoring / Open inputs | 0xFFFF |
| Input | Resistance measurement with constant current supply for 2- or 3-wire connections |
| Input protection | Protection against wiring with supply voltage |
| Digital converter resolution | 16- or 18-bit |
| Conversion time | Configurable for each channel |
| Conversion procedure | Sigma-delta |
| Output format | INT/DINT for temperature measurement UINT for resistance measurement |
| Resistance measurement range | 0.01 to 600 Ω / 0.1 to 4800 Ω |
| Resistance measurement resolution | 600 Ω: 0.01 Ω / 4800 Ω: 0.1 Ω |
| Sensor standard | EN 60751 |
| Insulation voltage between channel and bus | 1210 VDC |
| Linearization method | Internal |
| Measuring current | 250 µA with Pt100 or 600 Ω 100 µA with Pt1000 or 4800 Ω |
| Reference | 5000 Ω ±0.1% |
| Permissible input signal | Max. ±32 V |
| Max. gain drift | Pt100 and 600 Ω: ±0.015 %/°C Pt1000 and 4800 Ω: ±0.015 %/°C |
| Max. offset drift | Pt100 and 600 Ω: ±0.005 %/°C Pt1000 and 4800 Ω: ±0.0015 %/°C |
| Nonlinearity | <0.005% |
| Standardized range of values for resistance measurement | 600 Ω: 0.01 to 600.00 Ω / 4800 Ω: 0.1 to 4800.0 Ω |
| Crosstalk between channels | <-88 dB |
ICTD measurement
| Output format / Data type | INT |
| Output format / Temperature sensor | 1 LSB = 0x0001 = 100 nA |
| Input filter / Hardware | Third-order low-pass filter / Cutoff frequency 10 kHz |
| Input filter / Software | Configurable: Sinc 1 to 4 filter or FIR |
| Max. error at 25°C / Gain | ±0.15% |
| Max. error at 25°C / Offset | ±0.5% |
| Common-mode rejection / DC | -96 dB |
| Common-mode rejection / 50 Hz | -96 dB |
| Input | ICTD measurement |
| Type of output | 5 V power supply output for the ICTD sensor |
| Sensor | ICTD measuring probe |
| Digital converter resolution | 16-bit |
| Conversion time | Configurable for each channel |
| Conversion procedure | Sigma-delta |
| Current measurement range | 233 to 373 µA |
| Temperature sensor normalization | -40.0 to 100.0°C |
| Input protection | Protection against wiring with supply voltage Exception: Terminal "ICTD x +: 5 V" - see section "Pinout". |
| Max. gain drift | ±0.005%/°C |
| Max. offset drift | ±0.025%/°C |
| Crosstalk between channels | <-88 dB |
| Nonlinearity | <0.005% |
| Insulation voltage between channel and bus | 1210 VDC |
Electrical properties
| Electrical isolation | Channel isolated from bus Channel not isolated from channel |
Operating conditions
| Mounting orientation / Horizontal | Yes |
| Mounting orientation / Vertical | Yes |
| Installation elevation above sea level / 0 to 2000 m | No limitation |
| Installation elevation above sea level / >2000 m | Reduction of ambient temperature by 0.6°C per 100 m |
| Installation elevation above sea level / Maximum | 4000 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation / Horizontal mounting orientation | -25 to 60°C |
| Temperature / Operation / Vertical mounting orientation | -25 to 50°C |
| Temperature / Derating | - |
| Temperature / Storage | -40 to 85°C |
| Temperature / Transport | -40 to 85°C |
| Relative humidity / Operation | 5 to 95%, non-condensing |
| Relative humidity / Storage | 5 to 95%, non-condensing |
| Relative humidity / Transport | 5 to 95%, non-condensing |
Mechanical properties
| Dimensions / Width (pitch) | 27.5⁺⁰.² mm |
| Dimensions / Height | 124 mm |
| Dimensions / Depth | 92 mm |
| Note | Order terminal blocks separately (see section "Order data"). |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Manuals
3D CAD models
ECAD / EPLAN
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.