B&R X20AP3122

Calculates RMS values from currents and voltages Calculates active, reactive and apparent power Phasing detection Measures individual phases and calculates cumulative values Optional measurement of current through the neutral conductor Calculates frequency and harmonics with high precision NetTime timestamp: Moment when measured value groups are read Power monitoring These modules measure active, reactive and apparent power individually for each of the 3 phases as well as all of them collectively. The power consumption of each phase is also recorded individually and in total. In addition, the modules provide the RMS values for voltage and current on the 3 phases. When measuring the current, the value of the current through the neutral conductor can also be detected and monitored. Measurement of the mains frequency and the phase angle of the 3 phases (current and voltage) complete the power measurement data. Energy management The integrated functions on the modules map the immediate power requirements of the machine in detail as well as record its total power consumption. For the user, all relevant data is prepared and made available in the process image. The ability to measure currents and voltages up to the 31st harmonic enables higher precision recording of RMS values than is generally possible. This allows the modules to easily cope with irregular sine curves and makes them well-suited to renewable energy applications. In these types of applications, for example, being able to accurately measure the frequency at a resolution of 0.01 Hz between 45 and 65 Hz is a great advantage. In general, the modules are suitable for use with 1-phase, 2-phase or 3-phase networks. NetTime timestamp of readout moments For many applications, not only the measured value is important, but also the exact moment when a group of measured values is read out. The module is equipped with a NetTime timestamp function for this that supplies a timestamp for the recorded position and trigger time with microsecond accuracy. The timestamp function is based on synchronized timers. If a timestamp event occurs, the module immediately saves the current NetTime. After the respective data is transferred to the CPU, including this precise moment, the CPU can then evaluate the data using its own NetTime (or system time), if necessary.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
I/O module3-phase power and energy metering module for current transformers, groundable on one side
General information
Diagnostics / Module run/errorYes, using LED status indicator and software
Diagnostics / InputsYes, using LED status indicator and software
Power consumption / Bus0.85 W (Rev. <C0) 0.50 W (Rev. =C0) 0.45 W (Rev. >C0)
Power consumption / Internal I/O-
Insulation voltages / Voltage inputs - Current inputsTested at 1300 VAC, 1 min
Insulation voltages / Inputs - Bus / I/O power supplyTested at 5500 VDC, 1 min
Insulation voltages / Inputs - GroundTested at 5500 VDC, 1 min
Insulation voltages / Bus / I/O power supply - GroundTested at 510 VAC, 1 min
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X
Certifications / ULcULus E115267 Industrial control equipment
B&R ID code0xE7BF
Status indicatorsI/O function per channel, operating state, module status
Additional module power dissipation [W]2 W
Voltage inputs
Nominal voltage UN / Between phasesMax. 480 VAC
Nominal voltage UN / Phase to NMax. 277 VAC
Measurable frequency / Measurement range45 to 65 Hz
Measurable frequency / Resolution0.01 Hz
Number of phases3
Input impedance1.68 MΩ
Measurement categoryCAT II
Max. display value655 VAC
Resolution10 mV, with voltage connected directly
Rated frequency50 and 60 Hz
Current inputs
Nominal current IN / Secondary1 A
Nominal current IN / Primary65 A directly configurable, larger values through conversion in the application
Quantity4 AC inputs
Measurement categoryCAT II
Max. overload current8 x IN for 0.5 s
Max. measuring current1 A
Resolution1 mA, based on the primary current
Load250 mΩ
Measurement accuracy
Apparent energy / Per phase and arithmetic total±0.50%
Apparent energy / Vector sum±0.80%
URMS±0.65%
IRMS±0.65%
Effective, reactive and apparent power±0.80%
Frequency, power factor and phase angle±0.50%
Active energy per phase and total±0.40%
Active energy of fundamental frequency per phase and total±0.50%
Active energy of harmonics per phase and total±0.80%
Reactive energy per phase and total±0.50%
Electrical properties
Electrical isolationChannel isolated from bus Channel not isolated from channel
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mNot permitted
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation-25 to 60°C
Temperature / Operation / Vertical mounting orientation-25 to 50°C
Temperature / Derating-
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Relative humidity / Operation5 to 95%, non-condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
NoteOrder 1x terminal block X20TB32 separately. Order 1x bus module X20BM32 separately.
Pitch25⁺⁰.² mm

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.