B&R X20AT6402
6 inputs for thermocouples For sensor types J, K, N, S, B, R Additional direct raw value measurement Integrated terminal temperature compensation Configurable filter time Configurable resolution The module is equipped with 6 inputs for J, K, N, S, B and R thermocouple sensors. The module has an integrated terminal temperature compensation.
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Short description
| I/O module | 6 inputs for thermocouples |
General information
| Diagnostics / Module run/error | Yes, using LED status indicator and software |
| Diagnostics / Inputs | Yes, using LED status indicator and software |
| Power consumption / Bus | 0.01 W |
| Power consumption / Internal I/O | 0.91 W |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| Certifications / ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X |
| Certifications / UL | cULus E115267 Industrial control equipment |
| Certifications / HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| Certifications / DNV | Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck) |
| Certifications / CCS | Yes |
| Certifications / LR | ENV1 |
| Certifications / KR | Yes |
| Certifications / ABS | Yes |
| Certifications / BV | EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck |
| Certifications / KC | Yes |
| B&R ID code | 0x1BA9 |
| Status indicators | I/O function per channel, operating state, module status |
| Additional power dissipation caused by actuators (resistive) [W] | - |
Thermocouple temperature inputs
| Conversion time / 1 channel | 80.4 ms with 50 Hz filter |
| Conversion time / N channels | (n + 1) x 40.2 ms with 50 Hz filter |
| Measurement range / Sensor temperature / Type J: Fe-CuNi | -210 to 1200°C |
| Measurement range / Sensor temperature / Type K: NiCr-Ni | -270 to 1372°C |
| Measurement range / Sensor temperature / Type N: NiCrSi-NiSi | -270 to 1300°C (Rev. ≥D0) |
| Measurement range / Sensor temperature / Type S: PtRh10-Pt | -50 to 1768°C |
| Measurement range / Sensor temperature / Type B: PtRh30-PtRh6 | 0 to 1820°C |
| Measurement range / Sensor temperature / Type R: PtRh13-Pt | -50 to 1664°C |
| Measurement range / Terminal temperature | -25 to 85°C |
| Measurement range / Raw value | ±65.534 mV |
| Resolution / Sensor temperature | 1 LSB = 0.1°C or 0.01°C |
| Resolution / Terminal temperature | 1 LSB = 0.1°C |
| Resolution / Raw value output with respect to gain | 1 LSB = 1 µV or 2 µV |
| Normalization / Type J: Fe-CuNi | -210.0 to 1200.0°C or -210.00 to 1200.00°C |
| Normalization / Type K: NiCr-Ni | -270.0 to 1372.0°C or -270.00 to 1372.00°C |
| Normalization / Type N (Rev. ≥D0) | -270.0 to 1300.0°C or -270.00 to 1300.00°C |
| Normalization / Type S: PtRh10-Pt | -50.0 to 1768.0°C or -50.00 to 1768.00°C |
| Normalization / Type B: PtRh30-PtRh6 | 0 to 1820.0°C or 0 to 1820.00°C |
| Normalization / Type R: PtRh13-Pt | -50.0 to 1664.0°C or -50.00 to 1664.00°C |
| Normalization / Terminal temperature | -25.0 to 85.0°C or -25.00 to 85.00°C |
| Monitoring / Range undershoot | 0x8001 |
| Monitoring / Range overshoot | 0x7FFF |
| Monitoring / Open circuit | 0x7FFF |
| Monitoring / Open inputs | 0x7FFF |
| Monitoring / General fault | 0x8000 |
| Max. error at 25°C / Offset / Type J: Fe-CuNi | ±0.04% |
| Max. error at 25°C / Offset / Type K: NiCr-Ni | ±0.05% |
| Max. error at 25°C / Offset / Type N (Rev. ≥D0) | ±0.05% |
| Max. error at 25°C / Offset / Type S: PtRh10-Pt | ±0.11% |
| Max. error at 25°C / Offset / Type B: PtRh30-PtRh6 | ±0.13% |
| Max. error at 25°C / Offset / Type R: PtRh13-Pt | ±0.09% |
| Max. error at 25°C / Gain | ±0.06% |
| Max. offset drift / Type J: Fe-CuNi | ±0.0019%/°C |
| Max. offset drift / Type K: NiCr-Ni | ±0.0024%/°C |
| Max. offset drift / Type N (Rev. ≥D0) | ±0.0029%/°C |
| Max. offset drift / Type S: PtRh10-Pt | ±0.0079%/°C |
| Max. offset drift / Type B: PtRh30-PtRh6 | ±0.0114%/°C |
| Max. offset drift / Type R: PtRh13-Pt | ±0.0074%/°C |
| Common-mode rejection / DC | >70 dB |
| Common-mode rejection / 50 Hz | >70 dB |
| Insulation voltage / Between channel and bus | 500 Veff |
| Terminal temperature compensation precision / With artificial convection | ±4°C after 10 min |
| Terminal temperature compensation precision / With natural convection | ±2°C after 10 min |
| Input | Thermocouple |
| Digital converter resolution | 16-bit |
| Filter time | Configurable between 1 ms and 66.7 ms |
| Output format | INT |
| Terminal temperature compensation | Internal |
| Sensor standard | EN 60584 |
| Conversion procedure | Sigma-delta |
| Linearization method | Internal |
| Permissible input signal | Max. ±5 V |
| Input filter | First-order low-pass filter / cutoff frequency 500 Hz |
| Max. gain drift | ±0.01%/°C |
| Nonlinearity | ±0.001% |
| Common-mode range | ±15 V |
| Crosstalk between channels | <-70 dB |
Electrical properties
| Electrical isolation | Channel isolated from bus Channel not isolated from channel |
Operating conditions
| Mounting orientation / Horizontal | Yes |
| Mounting orientation / Vertical | Yes |
| Installation elevation above sea level / 0 to 2000 m | No limitation |
| Installation elevation above sea level / >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation / Horizontal mounting orientation | 0 to 55°C |
| Temperature / Operation / Vertical mounting orientation | 0 to 50°C |
| Temperature / Derating | - |
| Temperature / Storage | -40 to 85°C |
| Temperature / Transport | -40 to 85°C |
| Relative humidity / Operation | 5 to 95%, non-condensing |
| Relative humidity / Storage | 5 to 95%, non-condensing |
| Relative humidity / Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Order 1x terminal block X20TB12 separately. Order 1x bus module X20BM11 separately. |
| Pitch | 12.5⁺⁰.² mm |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Manuals
ECAD / EPLAN
Certificates
- 2226379 CSA Certificate of Compliance X20 X67
- 64331_A1 BV Certificate of Compliance X20
- 64331_A1 BV Certificate of Compliance X20(de)
- ABS Certificate of Product Design Assessment - X20 IO Series
- CCS Type Approval Certificate - X20
- Compass Safe Distance Certificate - X20
- E115267 UL Certificate of Compliance X20
- EU Data Act - X20 IO - Connected Product Information Notice
- EU Declaration ATEX X20
- EU Declaration of conformity PLC X20
- FTZU 09 ATEX 0083X
- KR Type Approval Certificate MIL39390-AC003 (X20 System)
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.