IAC

B&R X20BR7300

Fieldbus: CAN bus Automatic firmware update via the fieldbus Integrated I/O access in B&R Automation Studio The bus receiver makes it possible to connect X2X Link I/O nodes to CAN I/O. CAN I/O is a transfer protocol based on standard CAN bus that is fully integrated in the B&R system. Up to 43 logical I/O modules can be connected to the bus receiver. Up to 16 of these can be analog modules.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
Bus receiverCAN I/O slave
General information
Diagnostics / Module statusYes, using LED status indicator
Diagnostics / Bus functionYes, using LED status indicator
Diagnostics / Data transferYes, using LED status indicator
Diagnostics / OverloadYes, using LED status indicator and software
Power consumption / Internal I/O1.5 W
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X
B&R ID code0xEBED
Status indicatorsModule status, bus function, data transfer, I/O power supply, bus power supply
Power consumption for X2X Link power supply1.1 W
Additional power dissipation caused by actuators (resistive) [W]-
X2X Link and I/O power supply
Input voltage24 VDC -15% / +20%
FuseRequired line fuse: Max. 10 A slow-blow for wiring Integrated fuse for module, non-replaceable
Reverse polarity protectionYes
X2X Link power supply output
Nominal output power2 W
Parallel connectionNo
Redundant operationNo
Overload characteristicsShort-circuit proof, temporary overload
Output I/O power supply
Nominal output voltage24 VDC
Behavior on short circuitRequired line fuse
Permissible contact load10 A
Interfaces
FieldbusCAN I/O slave
VariantConnection via 12-pin terminal block X20TB12
Max. distance1000 m
Transfer rateMax. 1 Mbit/s
Default transfer rateAutomatic transfer rate detection
X2X Link cycle timePermanently set to 1 ms
Synchronization between bus systems possibleNo
Electrical properties
Electrical isolationX2X Link supply not isolated from X2X Link power supply I/O supply not isolated from I/O power supply CAN I/O not isolated from I/O or X2X Link power supply
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation-25 to 60°C
Temperature / Operation / Vertical mounting orientation-25 to 50°C
Temperature / Derating-
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Relative humidity / Operation5 to 95%, non-condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
NoteOrder 1x terminal block X20TB12 separately. Order 1x power supply bus module X20BM01 separately, X20 end cover plates (left and right) X20AC0SL1/X20AC0SR1 included
Pitch12.5⁺⁰.² mm

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.