IAC

B&R X20BT9400

X2X Link bus transmitter For seamless expansion of the system Up to 100 m segment length Supply for internal I/O power supply Integrated X2X Link power supply of the X67 system Operation only on the rightmost slot To connect an X20 system to an X67 system, a bus transmitter is simply connected to the end of the X20 block so that the X2X Link cable can be clamped. The bus transmitter also provides the X2X Link supply voltage of the X67 system. The X67 system power supply module that was previously always necessary can be omitted. The bus transmitter module is only permitted to be operated with a bus module where the internal I/O power supply is connected through (e.g. X20BM11). If the supply is used for the internal I/O power supply, this potential group is not permitted to be supplied by any other module. An I/O module with bus module X20BM01 must be used to isolate the potential group.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
Bus transmitterX2X Link bus transmitter with supply for I/O and integrated X67 system power supply
General information
Diagnostics / Module run/errorYes, using LED status indicator and software
Diagnostics / X2X bus functionYes, using LED status indicator
Power consumption / Internal I/O / As bus transmitter0.1 W
Power consumption / Internal I/O / Additionally as supply module0.6 W
Power consumption / Bus0.5 W
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X
Certifications / ULcULus E115267 Industrial control equipment
Certifications / HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
Certifications / KCYes
B&R ID code0xA238
Status indicatorsX2X bus function, operating state, module status
Power consumption for X2X Link power supply1.38 W
Additional power dissipation caused by actuators (resistive) [W]-
X67 X2X Link power supply input
Input voltage24 VDC -15% / +20%
Input currentMax. 0.5 A
FuseIntegrated, cannot be replaced
Reverse polarity protectionYes
X67 X2X Link power supply output
X67 modules supplied by BT9400 / Horizontal mounting orientationMax. 8 (nominal output power: 6 W)
X67 modules supplied by BT9400 / Vertical mounting orientationMax. 6 (nominal output power: 4.5 W)
Parallel connection with X67PS1300Yes
Overload characteristicsTemporarily short-circuit and overload-proof Observe the corresponding status message (LED "I") or evaluate the software status.
Input I/O power supply
Input voltage24 VDC -15% / +20%
FuseRequired line fuse: Max. 10 A, slow-blow
Reverse polarity protectionNo
Output I/O power supply
Nominal output voltage24 VDC
Behavior on short circuitRequired line fuse
Permissible contact load10 A
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation-25 to 60°C
Temperature / Operation / Vertical mounting orientation-25 to 50°C
Temperature / Derating-
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Relative humidity / Operation5 to 95%, non-condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
NoteOrder 1x terminal block X20TB12 separately. Order 1x bus module X20BM11 or 1x bus module X20BM15 separately.
Pitch12.5⁺⁰.² mm

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.