B&R X20cAP3121
Calculates RMS values from currents and voltages Calculates active, reactive and apparent power Phasing detection Measures individual phases and calculates cumulative values Optional measurement of current through the neutral conductor Calculates frequency and harmonics with high precision NetTime timestamp: Moment when measured value groups are read Power monitoring These modules measure active, reactive and apparent power individually for each of the 3 phases as well as all of them collectively. The power consumption of each phase is also recorded individually and in total. In addition, the modules provide the RMS values for voltage and current on the 3 phases. When measuring the current, the value of the current through the neutral conductor can also be detected and monitored. Measurement of the mains frequency and the phase angle of the 3 phases (current and voltage) complete the power measurement data. Energy management The integrated functions on the modules map the immediate power requirements of the machine in detail as well as record its total power consumption. For the user, all relevant data is prepared and made available in the process image. The ability to measure currents and voltages up to the 31st harmonic enables higher precision recording of RMS values than is generally possible. This allows the modules to easily cope with irregular sine curves and makes them well-suited to renewable energy applications. In these types of applications, for example, being able to accurately measure the frequency at a resolution of 0.01 Hz between 45 and 65 Hz is a great advantage. In general, the modules are suitable for use with 1-phase, 2-phase or 3-phase networks. NetTime timestamp of readout moments For many applications, not only the measured value is important, but also the exact moment when a group of measured values is read out. The module is equipped with a NetTime timestamp function for this that supplies a timestamp for the recorded position and trigger time with microsecond accuracy. The timestamp function is based on synchronized timers. If a timestamp event occurs, the module immediately saves the current NetTime. After the respective data is transferred to the CPU, including this precise moment, the CPU can then evaluate the data using its own NetTime (or system time), if necessary.
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Short description
| I/O module | 3-phase power and energy metering module for current transformers |
General information
| Diagnostics / Module run/error | Yes, using LED status indicator and software |
| Diagnostics / Inputs | Yes, using LED status indicator and software |
| Power consumption / Bus | 0.85 W (Rev. <C0) 0.50 W (Rev. =C0) 0.45 W (Rev. >C0) |
| Power consumption / Internal I/O | - |
| Insulation voltages / Inputs - Bus / I/O power supply | Tested at 5500 VDC, 1 min |
| Insulation voltages / Inputs - Ground | Tested at 5500 VDC, 1 min |
| Insulation voltages / Bus / I/O power supply - Ground | Tested at 510 VAC, 1 min |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| Certifications / ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X |
| Certifications / UL | cULus E115267 Industrial control equipment |
| Certifications / DNV | Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck) |
| Certifications / LR | ENV1 |
| Certifications / KR | Yes |
| Certifications / ABS | Yes |
| Certifications / BV | EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck |
| B&R ID code | 0xE214 |
| Status indicators | I/O function per channel, operating state, module status |
| Additional module power dissipation [W] | 2 W |
Voltage inputs
| Nominal voltage UN / Between phases | Max. 480 VAC |
| Nominal voltage UN / Phase to N | Max. 277 VAC |
| Measurable frequency / Measurement range | 45 to 65 Hz |
| Measurable frequency / Resolution | 0.01 Hz |
| Number of phases | 3 |
| Input impedance | 1.68 MΩ |
| Max. display value | 655 VAC |
| Resolution | 10 mV, with voltage connected directly |
| Rated frequency | 50 and 60 Hz |
Current inputs
| Nominal current IN / Secondary | 1 A |
| Nominal current IN / Primary | 65 A directly configurable, larger values through conversion in the application |
| Quantity | 4 AC inputs |
| Max. overload current | 8 x IN for 0.5 s |
| Max. measuring current | 1 A |
| Resolution | 1 mA, based on the primary current |
| Load | 500 mΩ |
Measurement accuracy
| Apparent energy / Per phase and arithmetic total | ±0.50% |
| Apparent energy / Vector sum | ±0.80% |
| URMS | ±0.65% |
| IRMS | ±0.65% |
| Effective, reactive and apparent power | ±0.80% |
| Frequency, power factor and phase angle | ±0.50% |
| Active energy per phase and total | ±0.40% |
| Active energy of fundamental frequency per phase and total | ±0.50% |
| Active energy of harmonics per phase and total | ±0.80% |
| Reactive energy per phase and total | ±0.50% |
Electrical properties
| Electrical isolation | Channel isolated from bus Channel not isolated from channel |
Operating conditions
| Mounting orientation / Horizontal | Yes |
| Mounting orientation / Vertical | Yes |
| Installation elevation above sea level / 0 to 2000 m | No limitation |
| Installation elevation above sea level / >2000 m | Not permitted |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation / Horizontal mounting orientation | -25 to 60°C |
| Temperature / Operation / Vertical mounting orientation | -25 to 50°C |
| Temperature / Derating | See section "Derating". |
| Temperature / Storage | -40 to 85°C |
| Temperature / Transport | -40 to 85°C |
| Relative humidity / Operation | Up to 100%, condensing |
| Relative humidity / Storage | 5 to 95%, non-condensing |
| Relative humidity / Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Order 1x terminal block X20TB32 separately. Order 1x bus module X20cBM32 separately. |
| Pitch | 25⁺⁰.² mm |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Manuals
3D CAD models
ECAD / EPLAN
Certificates
- 2226379 CSA Certificate of Compliance X20 X67
- ABS Certificate of Product Design Assessment - X20 IO Series
- E115267 UL Certificate of Compliance X20
- EU Data Act - X20 IO - Connected Product Information Notice
- EU Declaration ATEX X20
- EU Declaration of conformity PLC X20
- FTZU 09 ATEX 0083X
- KR Type Approval Certificate MIL39390-AC003 (X20 System)
- Lloyds Register (X20 only)
- RINA Type Approval Certificate - X20 / Power Panel T30
- TAA00000BJ DNV Type Approval Certificate X20
- UK Declaration ACOPOSmicro
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.