IAC

B&R X20cAT4222

4 inputs for resistance temperature measurement For PT100 and PT1000 Configurable sensor type per channel Direct resistance measurement Configurable 2- or 3- wire connections per module Configurable filter time The module is equipped with 4 inputs for PT100/PT1000 resistance temperature measurement.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
I/O module4 inputs for Pt100 or Pt1000 resistance temperature measurement
General information
Diagnostics / Module run/errorYes, using LED status indicator and software
Diagnostics / InputsYes, using LED status indicator and software
Power consumption / Bus0.01 W
Power consumption / Internal I/O1.1 W
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X
Certifications / ULcULus E115267 Industrial control equipment
Certifications / HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
Certifications / DNVTemperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)
Certifications / LRENV1
Certifications / KRYes
Certifications / ABSYes
Certifications / BVEC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck
B&R ID code0xE215
Status indicatorsI/O function per channel, operating state, module status
Additional power dissipation caused by actuators (resistive) [W]-
Resistance measurement temperature inputs
Conversion time / 1 channel20 ms with 50 Hz filter
Conversion time / 2 - 4 channels40 ms per channel with 50 Hz filter
Sensor / Sensor typeConfigurable per channel
Sensor / Pt100-200 to 850°C
Sensor / Pt1000-200 to 850°C
Max. error at 25°C / Gain±0.037%
Max. error at 25°C / Offset±0.0015%
Temperature sensor resolution / Pt1001 LSB = 0.1°C
Temperature sensor resolution / Pt10001 LSB = 0.1°C
Resistance measurement resolution / G = 10.1 Ω
Resistance measurement resolution / G = 20.05 Ω
Common-mode rejection / 50 Hz>80 dB
Common-mode rejection / DC>95 dB
Standardized range of values for resistance measurement / G = 10.1 to 4500 Ω
Standardized range of values for resistance measurement / G = 20.05 to 2250 Ω
Temperature sensor normalization / Pt100-200.0 to 850.0°C
Temperature sensor normalization / Pt1000-200.0 to 850.0°C
Temperature measurement monitoring / Range undershoot0x8001
Temperature measurement monitoring / Range overshoot0x7FFF
Temperature measurement monitoring / Open circuit0x7FFF
Temperature measurement monitoring / General fault0x8000
Temperature measurement monitoring / Open inputs0x7FFF
Resistance measurement monitoring / Range overshoot0xFFFF
Resistance measurement monitoring / Open circuit0xFFFF
Resistance measurement monitoring / General fault0xFFFF
Resistance measurement monitoring / Open inputs0xFFFF
InputResistance measurement with constant current supply for 2- or 3-wire connections
Digital converter resolution16-bit
Filter timeConfigurable between 1 ms and 66.7 ms
Conversion procedureSigma-delta
Output formatINT or UINT for resistance measurement
Resistance measurement range0.1 to 4500 Ω / 0.05 to 2250 Ω
Input filterFirst-order low-pass filter / cutoff frequency 500 Hz
Sensor standardEN 60751
Common-mode range>0.7 V
Insulation voltage between channel and bus500 Veff
Linearization methodInternal
Measuring current250 µA ±1.25%
Reference4530 Ω ±0.1%
Permissible input signalShort-term max. ±30 V
Max. gain drift±0.004%/°C
Max. offset drift±0.00015%/°C
Nonlinearity<0.001%
Crosstalk between channels<-93 dB
Electrical properties
Electrical isolationChannel isolated from bus Channel not isolated from channel
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation-25 to 60°C
Temperature / Operation / Vertical mounting orientation-25 to 50°C
Temperature / Derating-
Temperature / Starting temperatureYes, -40°C
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Relative humidity / OperationUp to 100%, condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
NoteOrder 1x terminal block X20TB12 separately. Order 1x bus module X20cBM11 separately.