IAC

B&R X20cAT6402

6 inputs for thermocouples For sensor types J, K, N, S, B, R Additional direct raw value measurement Integrated terminal temperature compensation Configurable filter time The module is equipped with 6 inputs for J, K, N, S, B and R thermocouple sensors. The module has an integrated terminal temperature compensation.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
I/O module6 inputs for thermocouples
General information
Diagnostics / Module run/errorYes, using LED status indicator and software
Diagnostics / InputsYes, using LED status indicator and software
Power consumption / Bus0.01 W
Power consumption / Internal I/O0.91 W
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X
Certifications / ULcULus E115267 Industrial control equipment
Certifications / HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
Certifications / DNVTemperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)
Certifications / LRENV1
Certifications / KRYes
Certifications / ABSYes
Certifications / BVEC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck
B&R ID code0xDD57
Status indicatorsI/O function per channel, operating state, module status
Additional power dissipation caused by actuators (resistive) [W]-
Thermocouple temperature inputs
Conversion time / 1 channel80.4 ms with 50 Hz filter
Conversion time / N channels(n + 1) x 40.2 ms with 50 Hz filter
Measurement range / Sensor temperature / Type J: Fe-CuNi-210 to 1200°C
Measurement range / Sensor temperature / Type K: NiCr-Ni-270 to 1372°C
Measurement range / Sensor temperature / Type N: NiCrSi-NiSi-270 to 1300°C (Rev. ≥D0)
Measurement range / Sensor temperature / Type S: PtRh10-Pt-50 to 1768°C
Measurement range / Sensor temperature / Type B: PtRh30-PtRh60 to 1820°C
Measurement range / Sensor temperature / Type R: PtRh13-Pt-50 to 1664°C
Measurement range / Terminal temperature-25 to 85°C
Measurement range / Raw value±65.534 mV
Resolution / Sensor temperature1 LSB = 0.1°C or 0.01°C
Resolution / Terminal temperature1 LSB = 0.1°C
Resolution / Raw value output with respect to gain1 LSB = 1 µV or 2 µV
Normalization / Type J: Fe-CuNi-210.0 to 1200.0°C or -210.00 to 1200.00°C
Normalization / Type K: NiCr-Ni-270.0 to 1372.0°C or -270.00 to 1372.00°C
Normalization / Type N (Rev. ≥D0)-270.0 to 1300.0°C or -270.00 to 1300.00°C
Normalization / Type S: PtRh10-Pt-50.0 to 1768.0°C or -50.00 to 1768.00°C
Normalization / Type B: PtRh30-PtRh60 to 1820.0°C or 0 to 1820.00°C
Normalization / Type R: PtRh13-Pt-50.0 to 1664.0°C or -50.00 to 1664.00°C
Normalization / Terminal temperature-25.0 to 85.0°C or -25.00 to 85.00°C
Monitoring / Range undershoot0x8001
Monitoring / Range overshoot0x7FFF
Monitoring / Open circuit0x7FFF
Monitoring / Open inputs0x7FFF
Monitoring / General fault0x8000
Max. error at 25°C / Offset / Type J: Fe-CuNi±0.04%
Max. error at 25°C / Offset / Type K: NiCr-Ni±0.05%
Max. error at 25°C / Offset / Type N (Rev. ≥D0)±0.05%
Max. error at 25°C / Offset / Type S: PtRh10-Pt±0.11%
Max. error at 25°C / Offset / Type B: PtRh30-PtRh6±0.13%
Max. error at 25°C / Offset / Type R: PtRh13-Pt±0.09%
Max. error at 25°C / Gain±0.06%
Max. offset drift / Type J: Fe-CuNi±0.0019%/°C
Max. offset drift / Type K: NiCr-Ni±0.0024%/°C
Max. offset drift / Type N (Rev. ≥D0)±0.0029%/°C
Max. offset drift / Type S: PtRh10-Pt±0.0079%/°C
Max. offset drift / Type B: PtRh30-PtRh6±0.0114%/°C
Max. offset drift / Type R: PtRh13-Pt±0.0074%/°C
Common-mode rejection / DC>70 dB
Common-mode rejection / 50 Hz>70 dB
Insulation voltage / Between channel and bus500 Veff
Terminal temperature compensation precision / With artificial convection±4°C after 10 min
Terminal temperature compensation precision / With natural convection±2°C after 10 min
InputThermocouple
Digital converter resolution16-bit
Filter timeConfigurable between 1 ms and 66.7 ms
Output formatINT
Terminal temperature compensationInternal
Sensor standardEN 60584
Conversion procedureSigma-delta
Linearization methodInternal
Permissible input signalMax. ±5 V
Input filterFirst-order low-pass filter / cutoff frequency 500 Hz
Max. gain drift±0.01%/°C
Nonlinearity±0.001%
Common-mode range±15 V
Crosstalk between channels<-70 dB
Electrical properties
Electrical isolationChannel isolated from bus Channel not isolated from channel
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation-25 to 60°C
Temperature / Operation / Vertical mounting orientation-25 to 50°C
Temperature / Derating-
Temperature / Starting temperatureYes, -40°C
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Relative humidity / OperationUp to 100%, condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
NoteOrder 1x terminal block X20TB12 separately. Order 1x bus module X20cBM11 separately.
Pitch12.5⁺⁰.² mm

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.