IAC

B&R X20cBC00E3

Fieldbus: PROFINET IO I/O configuration via the fieldbus Conformance Class B (RT) Minimum cycle time 1 ms Integrated switch for cabling multiple slaves 100 Mbit/s full duplex mode Up to 1440 bytes of input data and up to 1440 bytes of output data are possible Integrated website PROFINET diagnostics and module diagnostics during runtime from within the master environment Module and switch diagnostics during runtime using the website or SNMP PROFINET (Process Field Network) is an Industrial Ethernet protocol. It uses TCP/IP and is real-time capable. X20 modules or other modules that are based on X2X Link can be connected to the bus controller. Modular system configurations are optimally supported by PROFINET IO. Using the device description file (GSDML format), it is very easy to handle project configuration in the respective engineering tool from the manufacturer of the master device.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
Bus controllerPROFINET IO slave
General information
Diagnostics / Module statusYes, using LED status indicator and software
Diagnostics / Bus functionYes, using LED status indicator and software
Power consumption / Bus2.5 W
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X
Certifications / ULcULus E115267 Industrial control equipment
Certifications / HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
B&R ID code0xE4E0
Status indicatorsModule status, bus function
Additional power dissipation caused by actuators (resistive) [W]-
Interfaces
PROFINET attributes / Conformance classB
PROFINET attributes / Performance classRT
Transfer / Physical layer100BASE-TX
Transfer / Half-duplexYes
Transfer / Full-duplexYes
Transfer / AutonegotiationYes
Transfer / Auto-MDI/MDIXYes
Min. cycle time / Fieldbus1 ms
Min. cycle time / X2X Link250 μs
FieldbusPROFINET IO slave
Variant2x shielded RJ45 (switch)
Line lengthMax. 100 m between 2 stations (segment length)
Transfer rate100 Mbit/s
Synchronization between bus systems possibleYes
Electrical properties
Electrical isolationPROFINET isolated from bus and I/O
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation-25 to 60°C
Temperature / Operation / Vertical mounting orientation-25 to 50°C
Temperature / Derating-
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Relative humidity / OperationUp to 100%, condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
NoteOrder 1x terminal block X20TB12 separately. Order 1x power supply module X20cPS9400 separately. Order 1x bus base X20cBB80 separately.