IAC

B&R X20cHB1881

Hub expansion module 1x hub 100 BASE-FX Hot-swap-capable POWERLINK bus controllers X20BC8083 and X20BC8084 (starting with revision D0) and standalone hub X20HB8880 are equipped with a modular hub extension. 1 or 2 additional slots are available depending on the bus base. The X20HB1881 hub expansion module can be operated in these slots. It is important to note that the hardware revision of the X20BC8083 and X20HB8880 must be ≥F0. The hub expansion module is a 1x hub. The Ethernet connection is made using 62.5/125 μm or 50/125 µm fiber optic multimode cable with a duplex LC connection. The module and network status is indicated using LEDs.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
Hub1 Fast Ethernet interface for fiber optic cables for hub expansion
General information
Diagnostics / Module statusYes, using LED status indicator
Diagnostics / Bus functionYes, using LED status indicator
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X
Certifications / ULcULus E115267 Industrial control equipment
Certifications / HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
Certifications / DNVTemperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)
Certifications / LRENV1
Certifications / KRYes
Certifications / ABSYes
Certifications / BVEC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck
Status indicatorsModule status, bus function
Power consumption1.45 W
Additional power dissipation caused by actuators (resistive) [W]-
Interfaces
Transfer / Physical layer100BASE-FX
Transfer / Half-duplexYes
Transfer / Full-duplexNo
Transfer / AutonegotiationNo
Transfer / Auto-MDI/MDIXNo
Optical power budget / Glass fiber 62.5/125 µm, NA = 0.27511 dB
Optical power budget / Glass fiber 50/125 µm, NA = 0.2007.5 dB
Line length / Half-duplexMax. 175 m between 2 stations (segment length)
Line length / POWERLINKMax. 2 km between 2 stations (segment length)
TypeHub expansion module
Variant1x female duplex LC
Transfer rate100 Mbit/s
Hub propagation delay0.96 to 1 µs
Wave lengthTyp. 1300 nm Rx range: 1270 to 1380 nm Tx range: 1270 to 1380 nm
Cable fiber typeMultimode fiber with 62.5/125 µm or 50/125 µm core diameter On both sides: Male duplex LC connector
Electrical properties
Electrical isolationPower supply isolated from Ethernet
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation-25 to 60°C
Temperature / Operation / Vertical mounting orientation-25 to 50°C
Temperature / Derating-
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Relative humidity / OperationUp to 100%, condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
SlotHub expansion for X20cBC8084 and X20cHB8880

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.