IAC

B&R X20cIF1082-2

POWERLINK for real-time Ethernet communication Integrated hub for efficient cabling Configurable ring redundancy Poll response chaining Dynamic Node Allocation (DNA) The interface module is used for application-specific expansion of the X20 controllers. It is equipped with a POWERLINK interface. The interface has two RJ45 sockets. Both connections lead to an integrated hub. This makes it easy to create daisy-chain connections using POWERLINK.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
Communication module1x POWERLINK (V1/V2) managing or controlled node
General information
Diagnostics / Module statusYes, using LED status indicator and software
Diagnostics / Bus functionYes, using LED status indicator and software
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X
Certifications / ULcULus E115267 Industrial control equipment
Certifications / HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
Certifications / DNVTemperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)
Certifications / LRENV1
Certifications / KRYes
Certifications / ABSYes
Certifications / BVEC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck
B&R ID code0xE236
Status indicatorsModule status, bus function
Power consumption2 W
Additional power dissipation caused by actuators (resistive) [W]-
Interfaces
Transfer / Physical layer100BASE-TX
Transfer / Half-duplexYes
Transfer / Full-duplexNo
Transfer / AutonegotiationYes
Transfer / Auto-MDI/MDIXYes
FieldbusPOWERLINK (V1/V2) managing or controlled node
TypeType 4
Variant2x shielded RJ45 (hub)
Line lengthMax. 100 m between 2 stations (segment length)
Transfer rate100 Mbit/s
Hub propagation delay0.96 to 1 µs
ControllerPOWERLINK MAC
Electrical properties
Electrical isolationPLC isolated from POWERLINK (X1 and X2)
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation-25 to 60°C
Temperature / Operation / Vertical mounting orientation-25 to 50°C
Temperature / Derating-
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Relative humidity / OperationUp to 100%, condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
SlotIn the X20c PLC

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.