Digital and analog channels Selectable current and voltage for AI and AO Counter functions The module is a universal mixed module. On this module, digital I/O and analog I/O are combined. A current or voltage signal can be used for the analog I/O as desired. Counter functions on two of the digital inputs expand the range of use.
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Short description
| I/O module | 4 digital inputs, 2 digital outputs, 1 analog input, 1 analog output, special functions |
General information
| Diagnostics / Module run/error | Yes, using LED status indicator and software |
| Diagnostics / Analog inputs | Yes, using LED status indicator and software |
| Diagnostics / Digital outputs | Yes, using LED status indicator and software (output error status) |
| Power consumption / Bus | 0.01 W |
| Power consumption / Internal I/O | 1.75 W |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| Certifications / ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X |
| Certifications / UL | cULus E115267 Industrial control equipment |
| Certifications / HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| Certifications / DNV | Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck) |
| Certifications / CCS | Yes |
| Certifications / LR | ENV1 |
| Certifications / KR | Yes |
| Certifications / ABS | Yes |
| Certifications / BV | EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck |
| Certifications / KC | Yes |
| B&R ID code | 0x24C3 |
| Status indicators | I/O function per channel, operating state, module status |
| Additional power dissipation caused by actuators (resistive) [W] | - |
Digital inputs
| Input filter / Hardware | ≤2 µs |
| Input filter / Software | Default 1 ms, configurable between 0 and 25 ms in 0.2 ms increments |
| Switching threshold / Low | <5 VDC |
| Switching threshold / High | >15 VDC |
| Quantity | 4 |
| Nominal voltage | 24 VDC |
| Input characteristics per EN 61131-2 | Type 1 |
| Input voltage | 24 VDC -15% / +20% |
| Input current at 24 VDC | Typ. 3.3 mA |
| Input circuit | Sink |
| Connection type | 1-wire connections |
| Input resistance | Typ. 7.18 kΩ |
| Additional functions | 20 kHz event counting, gate measurement |
| Insulation voltage between channel and bus | 500 Veff |
Event counters
| Quantity | 2 |
| Signal form | Square wave pulse |
| Evaluation | Each negative edge, cyclic counter |
| Input frequency | Max. 20 kHz |
| Counter 1 | Input 1 |
| Counter 2 | Input 3 |
| Counter frequency | Max. 20 kHz |
| Counter size | 16-bit |
Gate time measurement
| Counter frequency / Internal | 48 MHz, 24 MHz, 12 MHz, 6 MHz, 3 MHz, 1.5 MHz, 750 kHz, 375 kHz, 187.5 kHz |
| Quantity | 1 |
| Signal form | Square wave pulse |
| Evaluation | Positive edge - Negative edge |
| Counter size | 16-bit |
| Length of pause between pulses | ≥100 µs |
| Pulse length | ≥20 µs |
| Supported inputs | Input 4 |
Analog inputs
| Digital converter resolution / Voltage | ±12-bit |
| Digital converter resolution / Current | 12-bit |
| Output format / Voltage | INT 0x8001 - 0x7FFF / 1 LSB = 0x0008 = 2.441 mV |
| Output format / Current | INT 0x0000 - 0x7FFF / 1 LSB = 0x0008 = 4.883 µA |
| Input impedance in signal range / Voltage | >1 MΩ |
| Input impedance in signal range / Current | - |
| Load / Voltage | - |
| Load / Current | <300 Ω |
| Permissible input signal / Voltage | Max. ±15 V |
| Permissible input signal / Current | Max. ±50 mA |
| Output of digital value during overload / Undershoot / Voltage | 0x8001 |
| Output of digital value during overload / Undershoot / Current | 0x0000 |
| Output of digital value during overload / Overshoot / Voltage | 0x7FFF |
| Output of digital value during overload / Overshoot / Current | 0x7FFF |
| Max. error / Voltage / Gain | 0.08% |
| Max. error / Voltage / Offset | 0.02% |
| Max. error / Current / Gain | 0 to 20 mA = 0.08% / 4 to 20 mA = 0.1% |
| Max. error / Current / Offset | 0 to 20 mA = 0.03% / 4 to 20 mA = 0.16% |
| Max. gain drift / Voltage | 0.01%/°C |
| Max. gain drift / Current | 0 to 20 mA = 0.009 %/°C 4 to 20 mA = 0.0113 %/°C |
| Max. offset drift / Voltage | 0.002%/°C |
| Max. offset drift / Current | 0 to 20 mA = 0.004 %/°C 4 to 20 mA = 0.005 %/°C |
| Nonlinearity / Voltage | <0.02% |
| Nonlinearity / Current | <0.02% |
| Quantity | 1 |
| Input | ±10 V or 0 to 20 mA / 4 to 20 mA, via different terminal connections |
| Input type | Single-ended |
| Conversion time | 400 µs, conversion runs asynchronous to the X2X Link cycle |
| Output format | INT |
| Input protection | Protection against wiring with supply voltage |
| Conversion procedure | Successive approximation |
| Input filter | Second-order low-pass filter / Cutoff frequency 1 kHz |
| Insulation voltage between channel and bus | 500 Veff |
Digital outputs
| Switching delay / 0 → 1 | <250 µs |
| Switching delay / 1 → 0 | <270 µs |
| Switching frequency / Resistive load | Max. 100 Hz |
| Switching frequency / Inductive load | See section "Switching inductive loads". |
| Quantity | 2 |
| Execution | Current-sourcing FET |
| Nominal voltage | 24 VDC |
| Switching voltage | 24 VDC -15% / +20% |
| Nominal output current | 0.5 A |
| Total nominal current | 1 A |
| Connection type | 1-wire connections |
| Output circuit | Source |
| Output protection | Thermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads, reverse polarity protection |
| Diagnostic status | Output monitoring with 10 ms delay |
| Leakage current when the output is switched off | 5 µA |
| RDS(on) | 105 mΩ |
| Peak short-circuit current | <14 A |
| Switch-on in the event of overload shutdown or short-circuit shutdown | Approx. 10 ms (depends on the module temperature) |
| Braking voltage when switching off inductive loads | Typ. 50 VDC |
| Insulation voltage between channel and bus | 500 Veff |
Analog outputs
| Max. error / Voltage / Gain | 0.04% |
| Max. error / Voltage / Offset | 0.0225% |
| Max. error / Current / Gain | 0.05% |
| Max. error / Current / Offset | 0.125% |
| Output format / Voltage | INT 0x8001 - 0x7FFF / 1 LSB = 0x0010 = 4.882 mV |
| Output format / Current | INT 0x0000 - 0x7FFF / 1 LSB = 0x0010 = 9.766 µA |
| Load per channel / Voltage | Max. ±10 mA, load ≥ 1 kΩ |
| Load per channel / Current | Max. load is 400 Ω |
| Max. gain drift / Voltage | 0.012%/°C |
| Max. gain drift / Current | 0.014 %/°C |
| Max. offset drift / Voltage | 0.0075% / °C |
| Max. offset drift / Current | 0.03 %/°C |
| Error caused by load change / Voltage | Max. 0.02%, from 10 MΩ → 1 kΩ, resistive |
| Error caused by load change / Current | Max. 0.5%, from 1 Ω → 400 Ω, resistive |
| Quantity | 1 |
| Output | ±10 V or 0 to 20 mA, via different terminal connections |
| Digital converter resolution | 12-bit |
| Conversion time | 300 µs, conversion runs asynchronous to the X2X Link cycle |
| Settling time on output change over entire range | 1 ms |
| Switch on/off behavior | Internal enable relay for startup and errors |
| Output protection | Short-circuit proof |
| Nonlinearity | <0.1% |
| Insulation voltage between channel and bus | 500 Veff |
Electrical properties
| Electrical isolation | Channel isolated from bus Channel not isolated from channel |
Operating conditions
| Mounting orientation / Horizontal | Yes |
| Mounting orientation / Vertical | Yes |
| Installation elevation above sea level / 0 to 2000 m | No limitation |
| Installation elevation above sea level / >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation / Horizontal mounting orientation | -25 to 60°C |
| Temperature / Operation / Vertical mounting orientation | -25 to 50°C |
| Temperature / Derating | See section "Derating". |
| Temperature / Storage | -40 to 85°C |
| Temperature / Transport | -40 to 85°C |
| Relative humidity / Operation | 5 to 95%, non-condensing |
| Relative humidity / Storage | 5 to 95%, non-condensing |
| Relative humidity / Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Order 1x terminal block X20TB12 separately. Order 1x bus module X20BM11 separately. |
| Pitch | 12.5⁺⁰.² mm |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Manuals
ECAD / EPLAN
Certificates
- 2226379 CSA Certificate of Compliance X20 X67
- 64331_A1 BV Certificate of Compliance X20
- 64331_A1 BV Certificate of Compliance X20(de)
- ABS Certificate of Product Design Assessment - X20 IO Series
- CCS Type Approval Certificate - X20
- Compass Safe Distance Certificate - X20
- E115267 UL Certificate of Compliance X20
- EU Data Act - X20 IO - Connected Product Information Notice
- EU Declaration ATEX X20
- EU Declaration of conformity PLC X20
- FTZU 09 ATEX 0083X
- KR Type Approval Certificate MIL39390-AC003 (X20 System)
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.