IAC

B&R X20CMR011

Measurement and evaluation of the ambient conditions in the control cabinet Recording ambient conditions Recording operating hours and power-on cycles Saving user data directly on the module Supports blackout mode 2 inputs for PT1000 temperature sensors 2 digital inputs 24 VDC 1 digital output 24 VDC The module is designed for measuring ambient conditions in the control cabinet as well as recording operating hours and power-on cycles. In addition, the module offers the option of storing user data directly on the module, is equipped with inputs/outputs and supports blackout mode. Measuring and evaluating ambient conditions The ambient conditions are continuously evaluated by the module. The duration in which individual parameters are within certain ranges is stored internally. This makes it possible, for example, to determine how long the system remained in a certain temperature range. The histograms recorded by the module can be read out by the user. Internal module memory for user data With 512 kB nonvolatile user memory (flash), data from the application can be saved directly on the module and also read back from the module. The data is therefore retained after the module or CPU is restarted and remains with the module in the event that the module is connected to another machine or system, for example. Data retention is maintenance-free – without batteries. Inputs/Outputs The module is equipped with 2 inputs for Pt1000 temperature sensors, 2 digital inputs (24 VDC) and 1 digital output (24 VDC). Blackout mode The integrated blackout mode ensures that module functionality is maintained even in the event of network failure.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
I/O moduleMeasurement of ambient conditions: Temperature in the module, relative humidity, vibration, shock, position, operating hours, power-on cycles 2 digital inputs, 1 digital output, 2 PT1000 temperature inputs
General information
Diagnostics / Module run/errorYes, using LED status indicator and software
Diagnostics / OutputYes, using LED status indicator and software (output error status)
Blackout mode / ScopeModule
Blackout mode / FunctionModule functionality
Blackout mode / Standalone modeNo
Power consumption / Bus0.4 W
Power consumption / Internal I/O0.1 W
Application memory / Type512 kB flash memory
Application memory / Sectors8 sectors, 64 kB each
Application memory / Data retention20 years at 55°C
Application memory / Guaranteed erase/write cycles100,000 per sector
Application memory / Error-correcting code (ECC)No
Application memory / Write protectionNo
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / DNVTemperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)
Certifications / CCSYes
Certifications / LRENV1
Certifications / KRYes
Certifications / ABSYes
Certifications / BVEC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck
B&R ID code0x28B4
Status indicatorsI/O function by channel, overload, memory access, operating state, module status
Additional power dissipation caused by actuators (resistive) [W]+0.075
Digital inputs
Input filter / Hardware≤100 μs
Input filter / SoftwareDefault 1 ms, configurable between 0 and 25 ms in 0.2 ms increments
Switching threshold / Low<5 VDC
Switching threshold / High>15 VDC
Quantity2
Nominal voltage24 VDC
Input voltage24 VDC -15% / +20%
Input current at 24 VDCTyp. 3.75 mA
Input circuitSink
Connection type1-wire connections
Input resistanceTyp. 6.4 kΩ
Insulation voltage between channel and bus500 Veff
Resistance measurement temperature inputs
Sensor / Pt1000-40 to 125°C
Temperature sensor resolution / Pt10001 LSB = 0.1°C
Temperature measurement monitoring / Range undershoot0x8001
Temperature measurement monitoring / Range overshoot0x7FFF
Temperature measurement monitoring / Open circuit0x7FFF
Temperature measurement monitoring / General fault0x8000
Temperature measurement monitoring / Open inputs0x7FFF
Quantity2
InputResistance measurement for 2-wire connections
Digital converter resolution12-bit
Filter timeConfigurable
Conversion time1 ms for all inputs
Output formatINT
Input filterAveraging with clipping function
Linearization methodInternal
Permissible input signalShort-term ±15 V
Max. gain drift0.0003 %/°C
Max. offset drift0.06 %/°C
Nonlinearity<0.010%
Temperature and humidity sensor
Temperature measurement / Measurement range-25 to 125°C
Temperature measurement / Resolution0.1°C/LSB
Temperature measurement / Max. error±0.3°C
Humidity measurement / Measurement range5 to 95%
Humidity measurement / Resolution1%/LSB
Humidity measurement / Max. error±2% at 10 to 80% relative humidity ±3% at <10 and >80% relative humidity
Sensor positionModule-internal
Sampling rate1 s
Acceleration and angle sensor
Acceleration measurement / Measurement range±16 g
Acceleration measurement / Resolution0.488 mg/LSB
Acceleration measurement / Linearity over temperature±1% at -40 to 85°C
Acceleration measurement / Offset calibration error±40 mg
Angular velocity measurement / Measurement range±2000 dps
Angular velocity measurement / Resolution±70 mdps per LSB
Angular velocity measurement / Linearity over temperature±1.5% at -40 to 85°C
Angular velocity measurement / Offset calibration error±10 dps
Sensor positionModule-internal
Sampling rateTyp. 10 ms
Digital outputs
Switching delay / 0 → 1<300 µs
Switching delay / 1 → 0<300 µs
Switching frequency / Resistive loadMax. 100 Hz
Switching frequency / Inductive loadSee section "Switching inductive loads".
Protective measures / Short-circuit proofYes
Protective measures / Overload-proofTemporary overload
Quantity1
VariantCurrent-sourcing FET
Nominal voltage24 VDC
Switching voltage24 VDC -15% / +20%
Nominal output current0.5 A
Connection type1- or 2-wire connections
Output circuitSource
Diagnostic statusOutput monitoring with 10 ms delay
Leakage current when the output is switched off120 µA
RDS(on)300 mΩ
Insulation voltage between channel and bus500 Veff
Electrical properties
Electrical isolationAnalog channel not isolated from bus Digital channel isolated from bus Digital channel not isolated from digital channel
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation-25 to 60°C
Temperature / Operation / Vertical mounting orientation-25 to 50°C
Temperature / Derating-
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Relative humidity / Operation5 to 95%, non-condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
NoteOrder 1x terminal block X20TB12 separately. Order 1x bus module X20BM11 separately.
Pitch12.5⁺⁰.² mm

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.