B&R X20CP1483
Intel x86-based, 100 MHz-compatible CPU with integrated I/O processor Onboard Ethernet, POWERLINK and USB 1 slot for modular interface expansion CompactFlash as removable application memory Fanless The Intel x86-based, 100 MHz-compatible X20CP1483 represents the entry-level X20 controllers. With an optimum price/performance ratio, it has the same basic features as all of the larger controllers. Onboard Ethernet and USB are standard. In addition, the controller has a POWERLINK connection for hard real-time communication. Another slot is available for an additional interface module to increase flexibility. The only difference between the two variants X20CP1483 and X20CP1483-1 is the size of the SDRAM.
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Short description
| Interfaces | 1x RS232, 1x Ethernet, 1x POWERLINK (V1/V2), 2x USB, 1x X2X Link |
| System module | Controller |
General information
| Diagnostics / Battery | Yes, using LED status indicator and software |
| Diagnostics / CPU function | Yes, using LED status indicator |
| Diagnostics / CompactFlash | Yes, using LED status indicator |
| Diagnostics / Ethernet | Yes, using LED status indicator |
| Diagnostics / POWERLINK | Yes, using LED status indicator |
| Diagnostics / Temperature | Yes, using software register |
| Support / ACOPOS support | Yes |
| Support / Visual Components support | Yes |
| Power consumption / Internal I/O | 0.6 W |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | Non-compliant |
| Certifications / ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X |
| Certifications / UL | cULus E115267 Industrial control equipment |
| Certifications / HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| Certifications / DNV | Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck) |
| Certifications / CCS | Yes |
| Certifications / LR | ENV1 |
| Certifications / KR | Yes |
| Certifications / ABS | Yes |
| Certifications / BV | EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck |
| Certifications / KC | Yes |
| B&R ID code | 0xA239 |
| Cooling | Fanless |
| Status indicators | CPU function, Ethernet, POWERLINK, CompactFlash, battery |
| Power consumption without memory card, interface module and USB | 6 W |
| Power consumption for X2X Link power supply | 1.42 W |
| Additional power dissipation caused by actuators (resistive) [W] | - |
CPU and X2X Link power supply
| Input voltage | 24 VDC -15% / +20% |
| Input current | Max. 2.2 A |
| Fuse | Integrated, cannot be replaced |
| Reverse polarity protection | Yes |
X2X Link power supply output
| Nominal output power | 7 W |
| Parallel connection | Yes |
| Redundant operation | Yes |
Input I/O power supply
| Input voltage | 24 VDC -15% / +20% |
| Fuse | Required line fuse: Max. 10 A, slow-blow |
Output I/O power supply
| Nominal output voltage | 24 VDC |
| Permissible contact load | 10 A |
Power supply - General information
| Diagnostics / RS232 data transfer | Yes, using LED status indicator |
| Diagnostics / Module run/error | Yes, using LED status indicator and software |
| Diagnostics / Overload | Yes, using LED status indicator and software |
| Electrical isolation / I/O supply - I/O power supply | No |
| Electrical isolation / CPU/X2X Link supply - CPU/X2X Link power supply | Yes |
| Status indicators | Overload, operating status, module status, RS232 data transfer |
Controller
| Processor / Type | x86 100 (compatible) |
| Processor / Clock frequency | 100 MHz |
| Processor / L2 cache | - |
| Processor / L1 cache for data and program code | 16 kB |
| Data buffering / Battery monitoring | Yes |
| Data buffering / Lithium battery | At least 3 years |
| Standard memory / RAM | 32 MB SDRAM |
| Standard memory / User RAM | 128 kB SRAM |
| CompactFlash slot | 1 |
| Real-time clock | Nonvolatile, resolution 1 s, -10 to 10 ppm accuracy at 25°C |
| Floating point unit (FPU) | Yes |
| Integrated I/O processor | Processes I/O data points in the background |
| Modular interface slots | 1 |
| Remanent variables | Max. 32 kB |
| Shortest task class cycle time | 1 ms |
| Typical instruction cycle time | 0.09 μs |
Interfaces
| Interface IF1 / Signal | RS232 |
| Interface IF1 / Variant | Connection via 12-pin terminal block X20TB12 |
| Interface IF1 / Max. distance | 900 m |
| Interface IF1 / Transfer rate | Max. 115.2 kbit/s |
| Interface IF2 / Transfer / Physical layer | 10BASE-T/100BASE-TX |
| Interface IF2 / Transfer / Half-duplex | Yes |
| Interface IF2 / Transfer / Full-duplex | Yes |
| Interface IF2 / Transfer / Autonegotiation | Yes |
| Interface IF2 / Transfer / Auto-MDI/MDIX | Yes |
| Interface IF2 / Signal | Ethernet |
| Interface IF2 / Variant | 1x RJ45 shielded |
| Interface IF2 / Line length | Max. 100 m between 2 stations (segment length) |
| Interface IF2 / Transfer rate | 10/100 Mbit/s |
| Interface IF3 / Transfer / Physical layer | 100BASE-TX |
| Interface IF3 / Transfer / Half-duplex | Yes |
| Interface IF3 / Transfer / Full-duplex | POWERLINK mode: No / Ethernet mode: Yes |
| Interface IF3 / Transfer / Autonegotiation | Yes |
| Interface IF3 / Transfer / Auto-MDI/MDIX | Yes |
| Interface IF3 / Fieldbus | POWERLINK (V1/V2) managing or controlled node |
| Interface IF3 / Type | Type 4 |
| Interface IF3 / Variant | 1x RJ45 shielded |
| Interface IF3 / Line length | Max. 100 m between 2 stations (segment length) |
| Interface IF3 / Transfer rate | 100 Mbit/s |
| Interface IF4 / Type | USB 1.1 |
| Interface IF4 / Variant | Type A |
| Interface IF4 / Max. output current | 0.5 A |
| Interface IF5 / Type | USB 1.1 |
| Interface IF5 / Variant | Type A |
| Interface IF5 / Max. output current | 0.5 A |
| Interface IF6 / Fieldbus | X2X Link master |
Electrical properties
| Electrical isolation | Ethernet (IF2), POWERLINK (IF3) and X2X (IF6) isolated from each other, from other interfaces and from PLC |
Operating conditions
| Mounting orientation / Horizontal | Yes |
| Mounting orientation / Vertical | Yes |
| Installation elevation above sea level / 0 to 2000 m | No limitation |
| Installation elevation above sea level / >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation / Horizontal mounting orientation | -25 to 60°C |
| Temperature / Operation / Vertical mounting orientation | -25 to 50°C |
| Temperature / Derating | See section "Derating". |
| Temperature / Storage | -40 to 85°C |
| Temperature / Transport | -40 to 85°C |
| Relative humidity / Operation | 5 to 95%, non-condensing |
| Relative humidity / Storage | 5 to 95%, non-condensing |
| Relative humidity / Transport | 5 to 95%, non-condensing |
Mechanical properties
| Dimensions / Width | 150 mm |
| Dimensions / Height | 99 mm |
| Dimensions / Depth | 85 mm |
| Note | Order application memory (CompactFlash) separately Backup battery included in delivery X20 end cover plate (right) included in delivery 12-pin X20 terminal block included in delivery Interface module slot covers included in delivery |
| Weight | 300 g |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Manuals
3D CAD models
ECAD / EPLAN
Certificates
- 2226379 CSA Certificate of Compliance X20 X67
- 64331_A1 BV Certificate of Compliance X20
- 64331_A1 BV Certificate of Compliance X20(de)
- ABS Certificate of Product Design Assessment - X20 IO Series
- CCS Type Approval Certificate - X20
- E115267 UL Certificate of Compliance X20
- EU Data Act - X20 PLC - Connected Product Information Notice
- FTZU 09 ATEX 0083X
- KR Type Approval Certificate MIL39390-AC003 (X20 System)
- Lloyds Register (X20 only)
- RINA Type Approval Certificate - X20 / Power Panel T30
- TAA00000BJ DNV Type Approval Certificate X20
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.