B&R X20cPS9600
Supply for Compact-S CPU, X2X Link and internal I/O power supply Galvanic isolation of supply and CPU / X2X Link power supply Redundancy of the CPU / X2X Link power supply possible through parallel operation of multiple power supply modules RS232 configurable as an online interface CAN bus The power supply module is used together with an X20 Compact-S PLC. It has a feed for the Compact-S PLC, X2X Link and the internal I/O power supply.
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Short description
| Power supply module | 24 VDC power supply module for Compact-S CPU, X2X Link power supply and I/O |
| Interfaces | 1x RS232, 1x CAN bus |
General information
| Diagnostics / Module run/error | Yes, using LED status indicator and software |
| Diagnostics / CAN bus data transfer | Yes, using LED status indicator |
| Diagnostics / RS232 data transfer | Yes, using LED status indicator |
| Diagnostics / Overload | Yes, using LED status indicator and software |
| Power consumption / Internal I/O | 0.6 W |
| Certifications / CE | Yes |
| Certifications / ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X |
| Certifications / UL | cULus E115267 Industrial control equipment |
| Certifications / DNV | Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck) |
| Certifications / LR | ENV1 |
| Certifications / KR | Yes |
| Certifications / ABS | Yes |
| B&R ID code | 0xFC38 |
| Status indicators | Overload, operating state, module status, RS232, CAN bus |
| Power consumption for X2X Link power supply | 1.42 W |
| Additional power dissipation caused by actuators (resistive) [W] | - |
CPU / X2X Link power supply input
| Input voltage | 24 VDC -15% / +20% |
| Input current | Max. 0.7 A |
| Fuse | Integrated, cannot be replaced |
| Reverse polarity protection | Yes |
CPU / X2X Link power supply output
| Nominal output power | 7 W |
| Parallel connection | Yes |
| Redundant operation | Yes |
| Overload characteristics | Short-circuit proof, temporary overload |
Input I/O power supply
| Input voltage | 24 VDC -15% / +20% |
| Fuse | Required line fuse: Max. 10 A, slow-blow |
| Reverse polarity protection | No |
Output I/O power supply
| Nominal output voltage | 24 VDC |
| Behavior on short circuit | Required line fuse |
| Permissible contact load | 10 A |
Interfaces
| Interface IF1 / Signal | RS232 |
| Interface IF1 / Variant | Connection made using 12-pin terminal block X20TB12 |
| Interface IF1 / Transfer rate | Max. 115.2 kbit/s |
| Interface IF3 / Signal | CAN bus |
| Interface IF3 / Variant | Connection made using 12-pin terminal block X20TB12 |
| Interface IF3 / Transfer rate | Max. 1 Mbit/s |
Electrical properties
| Electrical isolation | CPU/X2X Link supply isolated from CPU/X2X Link power supply I/O supply not isolated from I/O power supply |
Operating conditions
| Mounting orientation / Horizontal | Yes |
| Mounting orientation / Vertical | Yes |
| Installation elevation above sea level / 0 to 2000 m | No limitation |
| Installation elevation above sea level / >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation / Horizontal mounting orientation | -25 to 60°C |
| Temperature / Operation / Vertical mounting orientation | -25 to 50°C |
| Temperature / Derating | See section "Derating". |
| Temperature / Storage | -40 to 85°C |
| Temperature / Transport | -40 to 85°C |
| Relative humidity / Operation | Up to 100%, condensing |
| Relative humidity / Storage | 5 to 95%, non-condensing |
| Relative humidity / Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Order 1x terminal block X20TB12 separately. Order 1x Compact-S CPU base X20cBB5x separately. |
| Pitch | 12.5⁺⁰.² mm |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Manuals
ECAD / EPLAN
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.