IAC

B&R X20CS1012

Power supply for up to 64 slaves on the M-Bus Decentralized use of the communication interface The M-Bus master is designed as a single-width module and can be connected anywhere within the X20 I/O system. It can therefore be used decentrally for distributed topologies. The M-Bus master supports transfer rates of 300, 2400 and 9600 bit/s; up to 64 slaves supplied via M-Bus can be connected. M-Bus (Meter-Bus) is a relatively simple fieldbus for recording consumption data, such as from electricity or heat meters. It is based on a reverse polarity protected two-wire line and works according to the master-slave principle.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
Communication module1 M-Bus master for controlling up to 64 slaves
General information
Diagnostics / Module run/errorYes, using LED status indicator and software
Diagnostics / Data transferYes, using LED status indicator
Diagnostics / M-Bus power supplyYes, using LED status indicator and software
Power consumption / Bus0.2 W
Power consumption / Internal I/O0.35 W + (Number of slaves * 0.08 W)
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X
Certifications / ULcULus E115267 Industrial control equipment
Certifications / HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
B&R ID code0xCABF
Status indicatorsData transfer, M-Bus power supply, operating state, module status
Module power dissipation0.55 W + (Number of slaves * 0.006 W)
Additional power dissipation caused by actuators (resistive) [W]-
Insulation voltage between M-Bus and X2X Link500 VDC, 1 min
Interfaces
Interface / TypeM-Bus master
Interface / VariantConnection via 12-pin terminal block X20TB12
Interface / Max. distanceSee section "M-Bus".
Interface / Transfer rate300, 2400 or 9600 bit/s
Interface / Number of slavesMax. 64
Interface / Internal resistance of masterMax. 6 Ω
Interface / Bus voltage mark at 0 mAI/O supply voltage + (11.5 to 13.5) V
Interface / Bus voltage drop with space12 to 13.5 V
Interface / Overload shutdown250 mA ±10%
Interface / Bit threshold6 to 9 mA
Interface / Collision threshold24 to 36 mA
Interface / Received readjustment timeMax. 10 s
Interface / Bus cableShielded or unshielded
Electrical properties
Electrical isolationM-Bus isolated from bus M-Bus not isolated from I/O power supply
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation-25 to 60°C
Temperature / Operation / Vertical mounting orientation-25 to 50°C
Temperature / Derating-
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Relative humidity / Operation5 to 95%, non-condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
NoteOrder 1x terminal block X20TB12 separately. Order 1x bus module X20BM11 separately.
Pitch12.5⁺⁰.² mm