B&R X20CS1013

Integrated power supply Up to 64 operating devices (individual addresses) Up to 16 groups (group addresses) Up to 16 scenes (scene lighting values) The module is a DALI control device with an integrated power supply. Up to 64 operating devices can be connected. DALI stands for Digital Addressable Lighting Interface and enables easy and safe control of light fixtures using a standardized digital operating device interface. The DALI bus conforms with EN 62386 series of standards and is now supported by many electronic ballast manufacturers.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
Communication moduleDALI master
General information
Diagnostics / Module statusYes, using LED status indicator and software
Diagnostics / Bus statusYes, using LED status indicator and software
Power consumption / Bus0.2 W
Power consumption / Internal I/O0.4 W
Insulation voltages / Channel - Bus510 VAC / 1 minute
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X
Certifications / ULcULus E115267 Industrial control equipment
Certifications / HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
B&R ID code0xDE85
Additional power dissipation caused by actuators (resistive) [W]4
DALI bus
Signal voltage / Low-6.5 V to 6.5 V (typically 0 V)
Signal voltage / High11.5 V to 20.5 V (typically 16 V)
Signal current / Low≤250 mA (internally limited)
Signal current / High≤130 mA at voltage ≥11.5 V
Data signal slew rate (Manchester bi-phase) / Falling edge10 μs ≤ tfall ≤ 100 μs
Data signal slew rate (Manchester bi-phase) / Rising edge10 μs ≤ trise ≤ 100 μs
Insulation systemBasic insulation
Open-circuit voltage16.5 V ±5%
Short-circuit proofYes (current limiting)
Transfer rate1200 baud
Maximum number of slaves64
Electrical properties
Electrical isolationChannel isolated from bus
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation-25 to 60°C
Temperature / Operation / Vertical mounting orientation-25 to 50°C
Temperature / Derating-
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Relative humidity / Operation5 to 95%, non-condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
NoteOrder 1x terminal block X20TB06 or X20TB12 separately. Order 1x bus module X20BM11 separately.
Pitch12.5⁺⁰.² mm

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.