RS485/RS422 interface for serial, remote connection of complex devices to the X20 system Integrated terminating resistor In addition to the standard I/O, complex devices often need to be connected. The X20CS communication modules are intended precisely for cases like this. As normal X20 electronics modules, they can be placed anywhere on the remote backplane.

View on our store →

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
Communication module1x RS485/RS422
General information
Diagnostics / Module run/errorYes, using LED status indicator and software
Diagnostics / Data transferYes, using LED status indicator
Diagnostics / Terminating resistorYes, using LED status indicator
Power consumption / Bus0.01 W
Power consumption / Internal I/O1.44 W
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X
Certifications / ULcULus E115267 Industrial control equipment
Certifications / HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
Certifications / DNVTemperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)
Certifications / CCSYes
Certifications / LRENV1
Certifications / KRYes
Certifications / ABSYes
Certifications / BVEC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck
Certifications / KCYes
B&R ID code0x1FD0
Status indicatorsData transfer, terminating resistor, operating state, module status
Additional power dissipation caused by actuators (resistive) [W]-
Interfaces
Interface IF1 / SignalRS485/RS422
Interface IF1 / VariantConnection made using 12-pin terminal block X20TB12
Interface IF1 / Number of stationsRS485: Maximum 32 stations RS422: Maximum 10 stations (receivers)
Interface IF1 / Max. distance1200 m
Interface IF1 / Transfer rateMax. 115.2 kbit/s
Interface IF1 / FIFO buffer1 kB
Interface IF1 / Terminating resistorIntegrated in module
Interface IF1 / ControllerUART type 16C550 compatible
Electrical properties
Electrical isolationRS485/RS422 (IF1) isolated from bus and I/O power supply
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation-25 to 60°C
Temperature / Operation / Vertical mounting orientation-25 to 50°C
Temperature / DeratingSee section "Derating".
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Relative humidity / Operation5 to 95%, non-condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
NoteOrder 1x terminal block X20TB06 or X20TB12 separately. Order 1x bus module X20BM11 separately.
Pitch12.5⁺⁰.² mm