IAC

B&R X20cSO2530

2 safe relay outputs Output type "Relay" Relay module for 230 VAC / 24 VDC Switching current 6 A Normally open contact Single-channel isolated outputs This module is equipped with 2 safe relay outputs. The module can be used for controlling floating actuators in safety-related applications up to PL e or SIL 3. Safety relays are installed in the module. The positively driven feedback contacts are evaluated internally by the module. Safe digital output channels provide protection against automatic restart when network errors occur. This module is designed for X20 12-pin terminal blocks.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
I/O module2 relays with 1 normally open contact each, 230 VAC / 6 A, 24 VDC / 6 A
General information
Diagnostics / Module run/errorYes, using LED status indicator and software
Diagnostics / OutputsYes, using LED status indicator and software
Blackout mode / ScopeModule
Blackout mode / FunctionModule functionality
Blackout mode / Standalone modeNo
Power consumption / Bus0.26 W
Power consumption / Internal I/O1.15 W
Electrical isolation / Channel - BusYes
Electrical isolation / Channel - ChannelYes
Certifications / Relays / EN 50155Yes
Certifications / Relays / EN 61810-3Yes
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / Functional safetycULus FSPC E361559 Energy and industrial systems Certified for functional safety ANSI UL 1998:2013
Certifications / Functional safety #2IEC 61508:2010, SIL 3 EN 62061:2005/A2:2015, SIL 3 EN ISO 13849-1:2015, Cat. 4 / PL e IEC 61511:2004, SIL 3
Certifications / Functional safety #3EN 50156-1:2004
Certifications / ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X
Certifications / ULcULus E115267 Industrial control equipment
Certifications / HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
B&R ID code0xDD86
Status indicatorsI/O function per channel, operating state, module status
Additional power dissipation caused by actuators (resistive) [W]1.44
Safety characteristics
NoteSee section "Safety characteristics".
I/O power supply
Nominal voltage24 VDC
Voltage range24 VDC -15% / +20%
Integrated protective functionReverse polarity protection
Relay outputs
Switching delay / 0 → 1<50 ms
Switching delay / 1 → 0<50 ms
Max. switching capacity / UL 508B300 / R300
Quantity2
VariantRelay / Normally open contact, internal high-side and low-side control
Nominal output current5 mA to 6 A
Diagnostic statusContact position determined by positively driven contacts
Max. switching frequencySee section "Inrush current behavior for output channels".
Insulation voltage between channel and busSafe disconnection of 300 VAC per EN 50178
Insulation voltage between channel and channelTested at 1350 VAC
Contact resistance (without terminal block)20 mΩ
Contact service lifeSee "Contact service life".
Short-circuit/Overload protectionExternal 6 A gL/gG fuse (melting fuse), LS automat C characteristic 1.6 A
Switching voltage range5 to 24 VDC, 5 to 230 VAC
Coil voltage24 VDC -15% / +20%
Short-circuit proofYes, 1000 A (with specified short-circuit/overload protection)
Max. inrush current30 A for 20 ms
Overvoltage category per EN 60664-1II
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level0 to 2000 m, no limitation
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation-25 to 60°C
Temperature / Operation / Vertical mounting orientation-25 to 50°C
Temperature / DeratingSee section "Derating".
Temperature / Starting temperatureYes, -25°C
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Relative humidity / OperationUp to 100%, condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
NoteOrder 1x safety-keyed terminal block separately. Order 1x safety-keyed bus module separately.
Pitch25⁺⁰.² mm

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.