B&R X20DMF320
16 digital inputs Sink circuit 2 counter inputs with 40 kHz counter frequency ABR incremental encoder Period duration / gate time measurement 16 mixed channels optionally as input or output Source circuit Integrated output protection 3 PWM outputs All channels with 1-wire connections The module is equipped with 16 inputs and 16 mixed channels, optionally as input or output in 1-wire technology. The outputs are designed for a source output circuit, and the inputs are designed for a sink circuit.
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Short description
| I/O module | 16 digital inputs 24 VDC for 1-wire connections 16 mixed channels, 24 VDC input or output for 1-wire connections |
| Interfaces | 1x X2X Link |
General information
| Diagnostics / Module run/error | Yes, using LED status indicator and software |
| Diagnostics / Outputs | Yes, using LED status indicator and software (output state) |
| Power consumption / Bus | 0.04 W |
| Power consumption / Internal I/O | 2.7 W |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| Certifications / UL | cULus E115267 Industrial control equipment |
| B&R ID code | 0x2E86 |
| Status indicators | I/O function per channel, operating state, module status |
| Additional power dissipation caused by actuators (resistive) [W] | 0.312 W |
Digital inputs
| Input filter / Hardware | High-speed inputs: ≤7 μs Standard inputs and mixed channels: ≤100 μs |
| Input filter / Software | Default 0 ms, configurable between 0 and 25 ms in 0.1 ms intervals |
| Switching threshold / Low | <5 VDC |
| Switching threshold / High | >15 VDC |
| Quantity | 6 high-speed inputs, 10 standard inputs 16 mixed channels, configuration as input or output using software |
| Nominal voltage | 24 VDC |
| Input characteristics per EN 61131-2 | Type 1 |
| Input voltage | 24 VDC -15% / +20% |
| Input current at 24 VDC | Channels 1 to 6, high-speed inputs: Typ. 3.2 mA Channels 7 to 16, standard inputs: Typ. 2.4 mA Channels 17 to 32, mixed channel: Typ. 2.4 mA |
| Input circuit | Sink |
| Connection type | 1-wire connections |
| Input resistance | Channels 1 to 6, high-speed inputs: 7.5 kΩ Channels 7 to 16, standard inputs: 10 kΩ Channels 17 to 32, mixed channels: 10 kΩ |
| Additional functions | Channels 1 to 6, high-speed digital inputs: 2x 40 kHz event counting, 2x ABR incremental encoder, 2x period measurement, 2x gate time measurement, 2x counter latch function |
| Insulation voltage between channel and bus | 1210 VDC |
ABR incremental encoder
| Quantity | 2 |
| Encoder inputs | 24 V, asymmetrical |
| Counter size | 16-bit |
| Input frequency | 40 kHz |
| Evaluation | 4x |
Event counters
| Quantity | 2 |
| Signal form | Square wave pulse |
| Evaluation | Rising edge, falling edge or both edges The counter is cyclical. |
| Input frequency | 40 kHz |
| Counter size | 16-bit |
Edge detection / Time measurement
| Counter frequency / Internal | 48 MHz, 24 MHz, 12 MHz, 6 MHz, 3 MHz, 1.5 MHz, 750 kHz, 375 kHz, 187.5 kHz |
| Possible measurements | Period measurement, gate time measurement |
| Signal form | Square wave pulse |
| Evaluation | Positive edge - Negative edge |
| Counter size | 16-bit |
| Length of pause between pulses | ≥100 μs |
| Pulse length | ≥20 μs |
Digital outputs
| Pulse width modulation / Period duration | 1 to 65 ms |
| Pulse width modulation / Pulse duration | 0 to 100% |
| Pulse width modulation / Resolution for pulse duration | 0.1% |
| Switching delay / 0 → 1 | ≤300 μs |
| Switching delay / 1 → 0 | ≤300 μs |
| Switching frequency / Resistive load | Standard outputs: Max. 500 Hz High-speed outputs: Max. 1 kHz |
| Quantity | 13 standard outputs, 3 high-speed outputs All outputs designed as mixed channels, configurable as inputs or outputs using software |
| Variant | Current-sourcing FET |
| Nominal voltage | 24 VDC |
| Switching voltage | 24 VDC -15% / +20% |
| Nominal output current | 0.5 A per channel DO 22 and DO 30: Optional 0.5 or 2 A starting with Rev. B1 |
| Total nominal current | 8 A |
| Connection type | 1-wire connections |
| Output circuit | Source |
| Output protection | Thermal shutdown in the event of overcurrent or short circuit (see value "Short-circuit peak current") |
| Diagnostic status | Output monitoring with 25 ms delay |
| Leakage current when the output is switched off | 3 µA |
| RDS(on) | 78 mΩ |
| Peak short-circuit current | 6.95 A |
| Switch-on in the event of overload shutdown or short-circuit shutdown | Approx. 3 ms (depends on the module temperature) |
| Braking voltage when switching off inductive loads | Typ. 53 VDC |
| Insulation voltage between channel and bus | 1210 VDC |
Electrical properties
| Electrical isolation | Channel isolated from bus Channel not isolated from channel |
Operating conditions
| Mounting orientation / Horizontal | Yes |
| Mounting orientation / Vertical | Yes |
| Installation elevation above sea level / 0 to 2000 m | No limitation |
| Installation elevation above sea level / >2000 m | Reduction of ambient temperature by 0.6°C per 100 m |
| Installation elevation above sea level / Maximum | 4000 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation / Horizontal mounting orientation | -25 to 60°C |
| Temperature / Operation / Vertical mounting orientation | -25 to 45°C |
| Temperature / Derating | See section "Derating". |
| Temperature / Storage | -40 to 85°C |
| Temperature / Transport | -40 to 85°C |
| Relative humidity / Operation | 5 to 95%, non-condensing |
| Relative humidity / Storage | 5 to 95%, non-condensing |
| Relative humidity / Transport | 5 to 95%, non-condensing |
Mechanical properties
| Dimensions / Width (pitch) | 27.5⁺⁰.² mm |
| Dimensions / Height | 124 mm |
| Dimensions / Depth | 92 mm |
| Note | Order terminal blocks separately (see section "Order data"). |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Manuals
3D CAD models
ECAD / EPLAN
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.