IAC

B&R X20DMF320

16 digital inputs Sink circuit 2 counter inputs with 40 kHz counter frequency ABR incremental encoder Period duration / gate time measurement 16 mixed channels optionally as input or output Source circuit Integrated output protection 3 PWM outputs All channels with 1-wire connections The module is equipped with 16 inputs and 16 mixed channels, optionally as input or output in 1-wire technology. The outputs are designed for a source output circuit, and the inputs are designed for a sink circuit.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
I/O module16 digital inputs 24 VDC for 1-wire connections 16 mixed channels, 24 VDC input or output for 1-wire connections
Interfaces1x X2X Link
General information
Diagnostics / Module run/errorYes, using LED status indicator and software
Diagnostics / OutputsYes, using LED status indicator and software (output state)
Power consumption / Bus0.04 W
Power consumption / Internal I/O2.7 W
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ULcULus E115267 Industrial control equipment
B&R ID code0x2E86
Status indicatorsI/O function per channel, operating state, module status
Additional power dissipation caused by actuators (resistive) [W]0.312 W
Digital inputs
Input filter / HardwareHigh-speed inputs: ≤7 μs Standard inputs and mixed channels: ≤100 μs
Input filter / SoftwareDefault 0 ms, configurable between 0 and 25 ms in 0.1 ms intervals
Switching threshold / Low<5 VDC
Switching threshold / High>15 VDC
Quantity6 high-speed inputs, 10 standard inputs 16 mixed channels, configuration as input or output using software
Nominal voltage24 VDC
Input characteristics per EN 61131-2Type 1
Input voltage24 VDC -15% / +20%
Input current at 24 VDCChannels 1 to 6, high-speed inputs: Typ. 3.2 mA Channels 7 to 16, standard inputs: Typ. 2.4 mA Channels 17 to 32, mixed channel: Typ. 2.4 mA
Input circuitSink
Connection type1-wire connections
Input resistanceChannels 1 to 6, high-speed inputs: 7.5 kΩ Channels 7 to 16, standard inputs: 10 kΩ Channels 17 to 32, mixed channels: 10 kΩ
Additional functionsChannels 1 to 6, high-speed digital inputs: 2x 40 kHz event counting, 2x ABR incremental encoder, 2x period measurement, 2x gate time measurement, 2x counter latch function
Insulation voltage between channel and bus1210 VDC
ABR incremental encoder
Quantity2
Encoder inputs24 V, asymmetrical
Counter size16-bit
Input frequency40 kHz
Evaluation4x
Event counters
Quantity2
Signal formSquare wave pulse
EvaluationRising edge, falling edge or both edges The counter is cyclical.
Input frequency40 kHz
Counter size16-bit
Edge detection / Time measurement
Counter frequency / Internal48 MHz, 24 MHz, 12 MHz, 6 MHz, 3 MHz, 1.5 MHz, 750 kHz, 375 kHz, 187.5 kHz
Possible measurementsPeriod measurement, gate time measurement
Signal formSquare wave pulse
EvaluationPositive edge - Negative edge
Counter size16-bit
Length of pause between pulses≥100 μs
Pulse length≥20 μs
Digital outputs
Pulse width modulation / Period duration1 to 65 ms
Pulse width modulation / Pulse duration0 to 100%
Pulse width modulation / Resolution for pulse duration0.1%
Switching delay / 0 → 1≤300 μs
Switching delay / 1 → 0≤300 μs
Switching frequency / Resistive loadStandard outputs: Max. 500 Hz High-speed outputs: Max. 1 kHz
Quantity13 standard outputs, 3 high-speed outputs All outputs designed as mixed channels, configurable as inputs or outputs using software
VariantCurrent-sourcing FET
Nominal voltage24 VDC
Switching voltage24 VDC -15% / +20%
Nominal output current0.5 A per channel DO 22 and DO 30: Optional 0.5 or 2 A starting with Rev. B1
Total nominal current8 A
Connection type1-wire connections
Output circuitSource
Output protectionThermal shutdown in the event of overcurrent or short circuit (see value "Short-circuit peak current")
Diagnostic statusOutput monitoring with 25 ms delay
Leakage current when the output is switched off3 µA
RDS(on)78 mΩ
Peak short-circuit current6.95 A
Switch-on in the event of overload shutdown or short-circuit shutdownApprox. 3 ms (depends on the module temperature)
Braking voltage when switching off inductive loadsTyp. 53 VDC
Insulation voltage between channel and bus1210 VDC
Electrical properties
Electrical isolationChannel isolated from bus Channel not isolated from channel
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.6°C per 100 m
Installation elevation above sea level / Maximum4000 m
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation-25 to 60°C
Temperature / Operation / Vertical mounting orientation-25 to 45°C
Temperature / DeratingSee section "Derating".
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Relative humidity / Operation5 to 95%, non-condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
Dimensions / Width (pitch)27.5⁺⁰.² mm
Dimensions / Height124 mm
Dimensions / Depth92 mm
NoteOrder terminal blocks separately (see section "Order data").

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.