B&R X20DO6325
6 digital outputs Source connection 2-wire connections GND for signal supply Integrated output protection 1-wire connection type with 6-pin terminal block Diagnostic functions (open line, short circuit and overload/overtemperature) OSP mode The module is equipped with six outputs for 1 or 2-wire connections with diagnostic functions. The X20 6-pin terminal block can be used for universal 1-line wiring. Two-line wiring can be implemented using the 12-pin terminal block. The outputs on the module are designed for source connections.
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Short description
| I/O module | 6 digital outputs 24 VDC for 1- or 2-wire connections with diagnostic function |
General information
| Diagnostics / Module run/error | Yes, using LED status indicator and software |
| Diagnostics / Status outputs | Yes, using LED status indicator and software |
| Diagnostics / Diagnostic outputs | Yes, using LED status indicator and software |
| Power consumption / Bus | 0.15 W |
| Power consumption / Internal I/O | 0.4 W |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| Certifications / ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X |
| Certifications / UL | cULus E115267 Industrial control equipment |
| Certifications / HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| Certifications / DNV | Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck) |
| Certifications / CCS | Yes |
| Certifications / LR | ENV1 |
| Certifications / KR | Yes |
| Certifications / ABS | Yes |
| Certifications / BV | EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck |
| B&R ID code | 0xE284 |
| Status indicators | I/O function per channel, diagnostics per channel, operating state, module status |
| Additional power dissipation caused by actuators (resistive) [W] | 0.225 |
Digital outputs
| Diagnostic status / Open circuit | At <1 mA (typ.), detected if output OFF, delay approx. 10 ms |
| Diagnostic status / Short circuit to 24 VDC | Detected if output OFF, delay approx. 10 ms |
| Diagnostic status / Short circuit to GND | Detected if output ON, delay approx. 10 ms |
| Diagnostic status / Overload/Overtemperature | Detected if output ON, delay approx. 10 ms |
| Switching delay / 0 → 1 | <100 μs |
| Switching delay / 1 → 0 | <300 μs |
| Switching frequency / Resistive load | Max. 2000 Hz |
| Switching frequency / Inductive load | See section "Switching inductive loads". |
| Variant | Current-sourcing FET |
| Nominal voltage | 24 VDC |
| Switching voltage | 24 VDC -15% / +20% |
| Nominal output current | 0.5 A |
| Total nominal current | 3 A |
| Connection type | 1- or 2-wire connections |
| Output circuit | Source |
| Output protection | Thermal shutdown in the event of overcurrent or short circuit (see value "Short-circuit peak current") Internal freewheeling diode for switching inductive loads (see section "Switching inductive loads") |
| Leakage current when the output is switched off | <160 μA |
| RDS(on) | 150 mΩ |
| Peak short-circuit current | <40 A |
| Switch-on in the event of overload shutdown or short-circuit shutdown | Depends on the module temperature |
| Braking voltage when switching off inductive loads | 45 to 52 VDC |
| Insulation voltage between channel and bus | 510 Veff |
Electrical properties
| Electrical isolation | Channel isolated from bus Channel not isolated from channel and I/O power supply |
Operating conditions
| Mounting orientation / Horizontal | Yes |
| Mounting orientation / Vertical | Yes |
| Installation elevation above sea level / 0 to 2000 m | No limitation |
| Installation elevation above sea level / >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation / Horizontal mounting orientation | -25 to 60°C |
| Temperature / Operation / Vertical mounting orientation | -25 to 50°C |
| Temperature / Derating | - |
| Temperature / Storage | -40 to 85°C |
| Temperature / Transport | -40 to 85°C |
| Relative humidity / Operation | 5 to 95%, non-condensing |
| Relative humidity / Storage | 5 to 95%, non-condensing |
| Relative humidity / Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Order 1x terminal block X20TB06 or X20TB12 separately. Order 1x bus module X20BM11 separately. |
| Pitch | 12.5⁺⁰.² mm |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Manuals
ECAD / EPLAN
Certificates
- 2226379 CSA Certificate of Compliance X20 X67
- 64331_A1 BV Certificate of Compliance X20
- 64331_A1 BV Certificate of Compliance X20(de)
- ABS Certificate of Product Design Assessment - X20 IO Series
- CCS Type Approval Certificate - X20
- E115267 UL Certificate of Compliance X20
- EU Data Act - X20 IO - Connected Product Information Notice
- EU Declaration ATEX X20
- EU Declaration of conformity PLC X20
- FTZU 09 ATEX 0083X
- KR Type Approval Certificate MIL39390-AC003 (X20 System)
- Lloyds Register (X20 only)
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.