IAC

B&R X20DS438A

4 IO-Link devices 4 digital channels, can be configured as input or output 24 VDC and GND for sensor/actuator supply NetTime timestamps: IO-Link data The module is an IO-Link master that allows intelligent sensors and actuators to be connected to the X20 system in accordance with the IO-Link standard. The module can be used to operate up to 4 IO-Link devices. All IO-Link channels can be used either as standard digital inputs or outputs.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
I/O moduleIO-Link master with 4 IO-Link interfaces
General information
Diagnostics / Module run/errorYes, using LED status indicator and software
Diagnostics / IO-Link operating stateYes, using LED status indicator and software
Diagnostics / C/Q statusYes, using LED status indicator and software
Cable specification / Cable type3-pin standard sensor cable, unshielded
Cable specification / Cable lengthMax. 20 m
Cable specification / Line capacitanceMax. 3 nF
Cable specification / Loop resistanceMax. 6 Ω
Power consumption / Bus0.01 W
Power consumption / Internal I/O0.71 W
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X
Certifications / ULcULus E115267 Industrial control equipment
Certifications / HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
Certifications / DNVTemperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)
Certifications / CCSYes
Certifications / LRENV1
Certifications / KRYes
Certifications / ABSYes
Certifications / BVEC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck
B&R ID code0xCAC0
Status indicatorsIO-Link, operating state, module status
Additional power dissipation caused by actuators (resistive) [W]-
Sensor/Actuator power supply
Overload protection / Switch-off delayConfigurable using software
Overload protection / Switch-off durationConfigurable using software
VoltageI/O power supply minus voltage drop for short-circuit protection
Voltage drop for short-circuit protection at 0.5 AMax. 0.3 V
Power consumptionMax. 12 W per IO-Link interface
Short-circuit proofYes
IO-Link in master mode
Transfer rates / COM14.8 kbaud
Transfer rates / COM238.4 kbaud
Transfer rates / COM3230.4 kbaud
Limit values for COM3 / Max. connection capacity22 nF (cable + IO-Link device)
Limit values for COM3 / Max. load96 Ω / 250 mA
Data format1 start bit, 8 data bits, 1 parity bit (even), 1 stop bit
Bus level24 VDC (active), 0 VDC (resting voltage)
IO-Link in master mode or in SIO mode "digital output"
Switching delay / 0 → 1<10 µs
Switching delay / 1 → 0<10 µs
VariantBipolar, positive and negative switching
Peak short-circuit current<1.3 A
Residual voltage<0.7 VDC at nominal current 0.25 A
Switching voltageI/O power supply minus voltage drop for short-circuit protection and semiconductor switch
Voltage drop on semiconductor switchMax. 0.5 VDC at 0.25 A
Switching frequencyTyp. 25 kHz 300 kHz in IO-Link master mode
Switch-on in the event of overload shutdown or short-circuit shutdownConfigurable with software
Insulation voltage between IO-Link and bus500 Veff
IO-Link in SIO mode "Digital output"
Nominal voltage24 VDC
Nominal output current0.25 A
Total nominal currentMax. 1 A
Output circuitSink or source
Switching frequency (resistive load)Max. 500 Hz
Output protectionThermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads
IO-Link in SIO mode "digital input"
Input filter / Hardware300 ns
Input filter / Software-
Switching threshold / Low<5 VDC
Switching threshold / High>15 VDC
Nominal voltage24 VDC
Input characteristics per EN 61131-2Type 1
Input circuitSink
Input voltage24 VDC -15% / +20%
Input current at 24 VDCTyp. 4 mA
Input resistanceTyp. 6 kΩ
Insulation voltage between IO-Link and bus500 Veff
Electrical properties
Electrical isolationBus isolated from IO-Link IO-Link not isolated from IO-Link
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation-25 to 60°C
Temperature / Operation / Vertical mounting orientation-25 to 50°C
Temperature / Derating-
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Relative humidity / Operation5 to 95%, non-condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
NoteOrder 1x terminal block X20TB12 separately. Order 1x bus module X20BM11 separately.