IAC

B&R X20DS838A

8 IO-Link channels (port class A) Each IO-Link channel can be configured as a digital input or output (SIO mode) Additional digital input per IO-Link connection 24 VDC and GND for sensor/actuator power supply NetTime timestamps: IO-Link data The module is an IO-Link master that allows intelligent sensors and actuators to be connected per the IO-Link standard. The module can operate up to 8 IO-Link devices. The significant increase in cyclic data with this product variant enables optimal operation of IO-Link devices. Flatstream communication is now only used in exceptional cases. All IO-Link channels can also be operated in SIO mode and thus used as digital inputs or outputs. The module is also equipped with 8 additional digital inputs that can be used independently of the configuration of the IO-Link channels.

Lifecycle & replacement

Lifecycle status not indexed

No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.

IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.

Technical specifications

Short description
I/O moduleIO-Link master with 8 IO-Link interfaces
Interfaces1x X2X Link / X2X+
General information
Diagnostics / Module run/errorYes, using LED status indicator and software
Diagnostics / IO-Link operating stateYes, using LED status indicator and software
Diagnostics / C/Q statusYes, using LED status indicator and software
Cable specification / Cable type4-pin standard sensor cable, unshielded
Cable specification / Cable lengthMax. 20 m
Cable specification / Line capacitanceMax. 3 nF
Cable specification / Loop resistanceMax. 6 Ω
Power consumption / Bus0.6 W
Power consumption / Internal I/O1 W
Certifications / CEYes
Certifications / UKCAYes
Certifications / CRA (Cyber Resilience Act)In preparation
Certifications / ULcULus E115267 Industrial control equipment
B&R ID code0x30AE
Status indicatorsIO-Link, operating state, module status
Additional power dissipation caused by actuators (resistive) [W]-
Sensor/Actuator power supply
Overload protection / Switch-off delayConfigurable using software
Overload protection / Switch-off durationConfigurable using software
VoltageI/O power supply minus voltage drop for short-circuit protection
Voltage drop for short-circuit protection at 0.5 AMax. 0.3 V
Power consumptionMax. 12 W per IO-Link interface
Short-circuit proofYes
IO-Link in master mode
Transfer rates / COM14.8 kbaud
Transfer rates / COM238.4 kbaud
Transfer rates / COM3230.4 kbaud
Limit values for COM3 / Max. connection capacity22 nF (cable + IO-Link device)
Limit values for COM3 / Max. load96 Ω / 250 mA
Data format1 start bit, 8 data bits, 1 parity bit (even), 1 stop bit
Bus level24 VDC (active), 0 VDC (resting voltage)
IO-Link in master mode or in SIO mode "digital output"
Switching delay / 0 → 1<10 µs
Switching delay / 1 → 0<10 µs
VariantBipolar, positive and negative switching
Peak short-circuit current<1.3 A
Residual voltage<0.7 VDC at nominal current 0.25 A
Switching voltageI/O power supply minus voltage drop for short-circuit protection and semiconductor switch
Voltage drop on semiconductor switchMax. 0.5 VDC at 0.25 A
Switching frequencyTyp. 25 kHz 300 kHz in IO-Link master mode
Switch-on in the event of overload shutdown or short-circuit shutdownConfigurable with software
Insulation voltage between IO-Link and bus1210 VDC
IO-Link in SIO mode "Digital output"
Nominal voltage24 VDC
Nominal output current0.25 A
Total nominal currentMax. 2 A
Output circuitSink or source
Switching frequency (resistive load)Max. 500 Hz
Output protectionThermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads
IO-Link in SIO mode "digital input"
Input filter / Hardware300 ns
Input filter / Software-
Switching threshold / Low<5 VDC
Switching threshold / High>15 VDC
Nominal voltage24 VDC
Input characteristics per EN 61131-2Type 1
Input circuitSink
Input voltage24 VDC -15% / +20%
Input current at 24 VDCTyp. 4 mA
Input resistanceTyp. 6 kΩ
Insulation voltage between IO-Link and bus1210 VDC
Electrical properties
Electrical isolationBus isolated from IO-Link IO-Link not isolated from IO-Link
Operating conditions
Mounting orientation / HorizontalYes
Mounting orientation / VerticalYes
Installation elevation above sea level / 0 to 2000 mNo limitation
Installation elevation above sea level / >2000 mReduction of ambient temperature by 0.5°C per 100 m
Installation elevation above sea level / Maximum4000 m
Degree of protection per EN 60529IP20
Ambient conditions
Temperature / Operation / Horizontal mounting orientation-25 to 60°C
Temperature / Operation / Vertical mounting orientation-25 to 50°C
Temperature / Derating-
Temperature / Storage-40 to 85°C
Temperature / Transport-40 to 85°C
Relative humidity / Operation5 to 95%, non-condensing
Relative humidity / Storage5 to 95%, non-condensing
Relative humidity / Transport5 to 95%, non-condensing
Mechanical properties
Dimensions / Width (pitch)27.5 ⁺⁰.² mm
Dimensions / Height124 mm
Dimensions / Depth92 mm
NoteOrder terminal blocks separately (see section "Order data").

Documentation & CAD

Files hosted by B&R Industrial Automation; links open the official download page.

Get a quote for a replacement

Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.

Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.