B&R X20DS838A
8 IO-Link channels (port class A) Each IO-Link channel can be configured as a digital input or output (SIO mode) Additional digital input per IO-Link connection 24 VDC and GND for sensor/actuator power supply NetTime timestamps: IO-Link data The module is an IO-Link master that allows intelligent sensors and actuators to be connected per the IO-Link standard. The module can operate up to 8 IO-Link devices. The significant increase in cyclic data with this product variant enables optimal operation of IO-Link devices. Flatstream communication is now only used in exceptional cases. All IO-Link channels can also be operated in SIO mode and thus used as digital inputs or outputs. The module is also equipped with 8 additional digital inputs that can be used independently of the configuration of the IO-Link channels.
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Short description
| I/O module | IO-Link master with 8 IO-Link interfaces |
| Interfaces | 1x X2X Link / X2X+ |
General information
| Diagnostics / Module run/error | Yes, using LED status indicator and software |
| Diagnostics / IO-Link operating state | Yes, using LED status indicator and software |
| Diagnostics / C/Q status | Yes, using LED status indicator and software |
| Cable specification / Cable type | 4-pin standard sensor cable, unshielded |
| Cable specification / Cable length | Max. 20 m |
| Cable specification / Line capacitance | Max. 3 nF |
| Cable specification / Loop resistance | Max. 6 Ω |
| Power consumption / Bus | 0.6 W |
| Power consumption / Internal I/O | 1 W |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| Certifications / UL | cULus E115267 Industrial control equipment |
| B&R ID code | 0x30AE |
| Status indicators | IO-Link, operating state, module status |
| Additional power dissipation caused by actuators (resistive) [W] | - |
Sensor/Actuator power supply
| Overload protection / Switch-off delay | Configurable using software |
| Overload protection / Switch-off duration | Configurable using software |
| Voltage | I/O power supply minus voltage drop for short-circuit protection |
| Voltage drop for short-circuit protection at 0.5 A | Max. 0.3 V |
| Power consumption | Max. 12 W per IO-Link interface |
| Short-circuit proof | Yes |
IO-Link in master mode
| Transfer rates / COM1 | 4.8 kbaud |
| Transfer rates / COM2 | 38.4 kbaud |
| Transfer rates / COM3 | 230.4 kbaud |
| Limit values for COM3 / Max. connection capacity | 22 nF (cable + IO-Link device) |
| Limit values for COM3 / Max. load | 96 Ω / 250 mA |
| Data format | 1 start bit, 8 data bits, 1 parity bit (even), 1 stop bit |
| Bus level | 24 VDC (active), 0 VDC (resting voltage) |
IO-Link in master mode or in SIO mode "digital output"
| Switching delay / 0 → 1 | <10 µs |
| Switching delay / 1 → 0 | <10 µs |
| Variant | Bipolar, positive and negative switching |
| Peak short-circuit current | <1.3 A |
| Residual voltage | <0.7 VDC at nominal current 0.25 A |
| Switching voltage | I/O power supply minus voltage drop for short-circuit protection and semiconductor switch |
| Voltage drop on semiconductor switch | Max. 0.5 VDC at 0.25 A |
| Switching frequency | Typ. 25 kHz 300 kHz in IO-Link master mode |
| Switch-on in the event of overload shutdown or short-circuit shutdown | Configurable with software |
| Insulation voltage between IO-Link and bus | 1210 VDC |
IO-Link in SIO mode "Digital output"
| Nominal voltage | 24 VDC |
| Nominal output current | 0.25 A |
| Total nominal current | Max. 2 A |
| Output circuit | Sink or source |
| Switching frequency (resistive load) | Max. 500 Hz |
| Output protection | Thermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads |
IO-Link in SIO mode "digital input"
| Input filter / Hardware | 300 ns |
| Input filter / Software | - |
| Switching threshold / Low | <5 VDC |
| Switching threshold / High | >15 VDC |
| Nominal voltage | 24 VDC |
| Input characteristics per EN 61131-2 | Type 1 |
| Input circuit | Sink |
| Input voltage | 24 VDC -15% / +20% |
| Input current at 24 VDC | Typ. 4 mA |
| Input resistance | Typ. 6 kΩ |
| Insulation voltage between IO-Link and bus | 1210 VDC |
Electrical properties
| Electrical isolation | Bus isolated from IO-Link IO-Link not isolated from IO-Link |
Operating conditions
| Mounting orientation / Horizontal | Yes |
| Mounting orientation / Vertical | Yes |
| Installation elevation above sea level / 0 to 2000 m | No limitation |
| Installation elevation above sea level / >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Installation elevation above sea level / Maximum | 4000 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation / Horizontal mounting orientation | -25 to 60°C |
| Temperature / Operation / Vertical mounting orientation | -25 to 50°C |
| Temperature / Derating | - |
| Temperature / Storage | -40 to 85°C |
| Temperature / Transport | -40 to 85°C |
| Relative humidity / Operation | 5 to 95%, non-condensing |
| Relative humidity / Storage | 5 to 95%, non-condensing |
| Relative humidity / Transport | 5 to 95%, non-condensing |
Mechanical properties
| Dimensions / Width (pitch) | 27.5 ⁺⁰.² mm |
| Dimensions / Height | 124 mm |
| Dimensions / Depth | 92 mm |
| Note | Order terminal blocks separately (see section "Order data"). |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.