B&R X20EM1613
Intel Atom 1.3 GHz with integrated I/O processor Ethernet, POWERLINK V2 with poll-response chaining, onboard USB and RS485 1 slot for modular interface expansion 1 GB LPDDR4 SDRAM 2 GB onboard flash drive Fanless No battery This compact yet powerful controller is based on Intel Atom processor technology. The fanless, battery-free design of this controller means it is completely maintenance-free. The basic configuration includes USB, Ethernet, POWERLINK V2, RS485 and a flash drive. In addition, 1 slot can be used for X20 interface modules to increase flexibility.
Lifecycle & replacement
No manufacturer-published lifecycle data for B&R part numbers is indexed here yet. Ask IAC to check availability and an upgrade path.
IAC stocks legacy spares and exchange units and quotes upgrade paths. Send us the nameplate details and we will confirm a compatible replacement.
Technical specifications
Short description
| Interfaces | 1x RS485, 1x Ethernet (2-port switch), 1x POWERLINK (V2), 2x USB, 1x X2X Link |
| System module | Controller |
General information
| Diagnostics / CPU function | Yes, using LED status indicator |
| Diagnostics / Ethernet | Yes, using LED status indicator |
| Diagnostics / I/O power supply | Yes, using software and LED status indicator |
| Diagnostics / POWERLINK | Yes, using LED status indicator |
| Diagnostics / Temperature | Yes, using software register |
| Support / Controller redundancy | No |
| Support / Storage health data support | Yes |
| Support / ACOPOS support | Yes |
| Support / Visual Components support | Yes |
| Support / Multicore support | No |
| Power consumption / Internal I/O | 0.56 W |
| Certifications / CE | Yes |
| Certifications / UKCA | Yes |
| Certifications / CRA (Cyber Resilience Act) | In preparation |
| Certifications / ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X |
| Certifications / UL | cULus E115267 Industrial control equipment |
| Certifications / HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| B&R ID code | 0x289C |
| Cooling | Fanless |
| Status indicators | CPU function, Ethernet, POWERLINK, RS485, I/O power supply |
| Power consumption | 5.5 W |
| Power consumption for X2X Link power supply | 0.6 W |
| Additional power dissipation caused by actuators (resistive) [W] | - |
CPU and X2X Link power supply
| Input voltage | 24 VDC -20% / +25% (nominal voltage: 24 VDC) (max. input power at nominal voltage: 34 W) |
| Input current | Max. 1.4 A at 24 VDC |
| Fuse | Integrated, cannot be replaced |
| Reverse polarity protection | Yes |
X2X Link power supply output
| Nominal output power | 3.5 W |
| Parallel connection | Yes |
| Redundant operation | Yes |
Input I/O power supply
| Input voltage | 24 VDC -15% / +20% (nominal voltage: 24 VDC) (max. input power at nominal voltage: 240 W) |
| Fuse | Required line fuse: Max. 10 A, slow-blow |
Output I/O power supply
| Nominal output voltage | 24 VDC |
| Permissible contact load | 10 A |
Controller
| Processor / L1 cache / Data code | 24 kB |
| Processor / L1 cache / Program code | 32 kB |
| Processor / Type | Atom E3915 |
| Processor / Clock frequency | 1.3 GHz |
| Processor / L2 cache | 1 MB |
| Standard memory / RAM | 1 GB LPDDR4 SDRAM |
| Application memory / Writable data amount / Guaranteed | 40 TB |
| Application memory / Writable data amount / Results for 5 years | 21.9 GB/day |
| Application memory / Type | 2 GB eMMC flash memory |
| Application memory / Data retention | 10 years |
| Application memory / Guaranteed erase/write cycles | 20,000 |
| Application memory / Error-correcting code (ECC) | Yes |
| Real-time clock | Retention for at least 300 hours, typ. 1000 hours at 25°C, 1 s resolution, <30 s/month accuracy at 25°C |
| Floating point unit (FPU) | Yes |
| Integrated I/O processor | Processes I/O data points in the background |
| Modular interface slots | 1 |
| Remanent variables | Max. 64 kB, retention >10 years |
| Shortest task class cycle time | 100 µs |
| Typical instruction cycle time | 0.0015 µs |
Interfaces
| Interface IF2 / Transfer / Physical layer | 10BASE-T/100BASE-TX |
| Interface IF2 / Transfer / Half-duplex | Yes |
| Interface IF2 / Transfer / Full-duplex | Yes |
| Interface IF2 / Transfer / Autonegotiation | Yes |
| Interface IF2 / Transfer / Auto-MDI/MDIX | Yes |
| Interface IF2 / Signal | Ethernet |
| Interface IF2 / Variant | 2x shielded RJ45 (switch) |
| Interface IF2 / Line length | Max. 100 m between 2 stations (segment length) |
| Interface IF2 / Transfer rate | 10/100 Mbit/s |
| Interface IF3 / Transfer / Physical layer | 100BASE-TX |
| Interface IF3 / Transfer / Half-duplex | Yes |
| Interface IF3 / Transfer / Full-duplex | POWERLINK mode: No / Ethernet mode: Yes |
| Interface IF3 / Transfer / Autonegotiation | Yes |
| Interface IF3 / Transfer / Auto-MDI/MDIX | Yes |
| Interface IF3 / Fieldbus | POWERLINK (V2) managing or controlled node |
| Interface IF3 / Type | Type 4 |
| Interface IF3 / Variant | 1x RJ45 shielded |
| Interface IF3 / Line length | Max. 100 m between 2 stations (segment length) |
| Interface IF3 / Transfer rate | 100 Mbit/s |
| Interface IF4 / Type | USB 1.1/2.0 |
| Interface IF4 / Variant | Type A |
| Interface IF4 / Max. output current | 0.5 A |
| Interface IF5 / Type | USB 1.1/2.0 |
| Interface IF5 / Variant | Type A |
| Interface IF5 / Max. output current | 0.5 A |
| Interface IF6 / Fieldbus | X2X Link master |
| Interface IF7 / Signal | RS485 |
| Interface IF7 / Variant | Connection via 6-pin terminal block |
| Interface IF7 / Max. distance | 1000 m |
| Interface IF7 / Transfer rate | Max. 115.2 kbit/s |
| Interface IF7 / Terminating resistor | Integrated in PLC, not switchable |
Electrical properties
| Electrical isolation | Ethernet (IF2), POWERLINK (IF3), X2X (IF6) and RS485 (IF7) isolated from each other, from other interfaces and from PLC I/O to PLC isolated from all interfaces USB (IF4 and IF5) and slot for X20 interface modules not isolated from PLC |
Operating conditions
| Mounting orientation / Horizontal | Yes |
| Mounting orientation / Vertical | Yes |
| Installation elevation above sea level / 0 to 2000 m | No limitation |
| Installation elevation above sea level / >2000 m | Reduction of ambient temperature by 0.6°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature / Operation / Horizontal mounting orientation | -25 to 60°C |
| Temperature / Operation / Vertical mounting orientation | -25 to 50°C |
| Temperature / Derating | - |
| Temperature / Storage | -40 to 70°C |
| Temperature / Transport | -40 to 70°C |
| Relative humidity / Operation | 5 to 95%, non-condensing |
| Relative humidity / Storage | 5 to 95%, non-condensing |
| Relative humidity / Transport | 5 to 95%, non-condensing |
Mechanical properties
| Dimensions / Width | 82.5 mm |
| Dimensions / Height | 124 mm |
| Dimensions / Depth | 92 mm |
| Note | X20 end cover plate (right) included in delivery 2- and 6-pin terminal block included in delivery Interface module slot cover included in delivery |
| Weight | 530 g |
Documentation & CAD
Files hosted by B&R Industrial Automation; links open the official download page.
Datasheets
Manuals
3D CAD models
ECAD / EPLAN
Get a quote for a replacement
Industrial Automation Co. stocks, sources, and repairs B&R parts — new, refurbished, or exchange units with warranty.
Specifications from the official B&R product catalog. Always confirm against the datasheet for your exact revision.